{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T08:10:07Z","timestamp":1777536607081,"version":"3.51.4"},"reference-count":54,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2009,11,20]],"date-time":"2009-11-20T00:00:00Z","timestamp":1258675200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Acta Ophthalmologica"],"published-print":{"date-parts":[[2010,5]]},"abstract":"<jats:title>Abstract.<\/jats:title><jats:p><jats:bold>Purpose:\u2002<\/jats:bold> To report the 24\u2010month experience of the Stanford University Network for Diagnosis of Retinopathy of Prematurity (SUNDROP) telemedicine initiative.<\/jats:p><jats:p><jats:bold>Methods:\u2002<\/jats:bold> Retrospective analysis of the SUNDROP archival data gathered between 1 December 2005 and 30 November 2007 to evaluate this diagnostic technology for ROP screening. One hundred and sixty consecutively enrolled infants meeting ROP examination criteria were screened with the RetCam II and evaluated by the SUNDROP reading centre at Stanford University. Nurses obtained five or six images in each eye. All patients also received a dilated examination within 1\u2003week of discharge. Outcomes included treatment\u2010warranted retinopathy of prematurity (TW\u2010ROP) and anatomical outcomes.<\/jats:p><jats:p><jats:bold>Results:\u2002<\/jats:bold> In the initial 24\u2010month period, the SUNDROP telemedicine initiative has not missed any TW\u2010ROP. A total of 160 infants (320 eyes) were imaged, resulting in 669 exams and 7556 images. Seven infants were identified with TW\u2010ROP; six underwent laser photocoagulation and one regressed spontaneously. The sensitivity was 100%, with specificity of 99.4%. No patient progressed to retinal detachment or other adverse outcomes.<\/jats:p><jats:p><jats:bold>Conclusion:\u2002<\/jats:bold> The SUNDROP telemedicine screening initiative for ROP has been proven to have a high degree of sensitivity and specificity for the identification of treatment\u2010warranted disease. All cases of treatment\u2010warranted disease were captured. There were no adverse outcomes.<\/jats:p>","DOI":"10.1111\/j.1755-3768.2009.01715.x","type":"journal-article","created":{"date-parts":[[2009,11,20]],"date-time":"2009-11-20T11:46:35Z","timestamp":1258717595000},"page":"317-322","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":40,"title":["Stanford University Network for Diagnosis of Retinopathy of Prematurity (SUNDROP): 24\u2010month experience with telemedicine screening"],"prefix":"10.1111","volume":"88","author":[{"given":"Yohko","family":"Murakami","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ruwan A.","family":"Silva","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Atul","family":"Jain","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eleonora M.","family":"Lad","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jarel","family":"Gandhi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Darius M.","family":"Moshfeghi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2010,4,27]]},"reference":[{"key":"e_1_2_5_2_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1651-2227.2006.00180.x"},{"key":"e_1_2_5_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1651-2227.2006.00179.x"},{"key":"e_1_2_5_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1651-2227.2006.00178.x"},{"key":"e_1_2_5_5_1","volume-title":"Ophthalmologists warn of shortage in specialists who treat premature babies with blinding eye condition","author":"American Academy of Ophthalmology","year":"2006"},{"key":"e_1_2_5_6_1","first-page":"273","article-title":"Screening examination of premature infants for retinopathy of prematurity. A joint statement of the American Academy of Pediatrics, the American Association for Pediatric Ophthalmology and Strabismus, and the American Academy of Ophthalmology","volume":"100","author":"American Academy of Pediatrics","year":"1997","journal-title":"Pediatrics"},{"key":"e_1_2_5_7_1","doi-asserted-by":"publisher","DOI":"10.1542\/peds.108.3.809"},{"key":"e_1_2_5_8_1","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2005-2749"},{"key":"e_1_2_5_9_1","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-146-7-200704030-00008"},{"key":"e_1_2_5_10_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.iae.0000244291.09499.88"},{"key":"e_1_2_5_11_1","doi-asserted-by":"publisher","DOI":"10.1146\/annurev.publhealth.21.1.613"},{"key":"e_1_2_5_12_1","doi-asserted-by":"publisher","DOI":"10.1089\/tmj.1.1995.1.133"},{"key":"e_1_2_5_13_1","first-page":"126","article-title":"Assessment of image\u2010based technology: impact of referral cutoff on accuracy and reliability of remote retinopathy of prematurity diagnosis","author":"Chiang MF","year":"2005","journal-title":"AMIA Annu Symp Proc"},{"key":"e_1_2_5_14_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.124.3.322"},{"key":"e_1_2_5_15_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2006.091900"},{"key":"e_1_2_5_16_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.125.7.875"},{"key":"e_1_2_5_17_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.125.11.1531"},{"key":"e_1_2_5_18_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1984.01040030908011"},{"key":"e_1_2_5_19_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.123.7.991"},{"key":"e_1_2_5_20_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.121.12.1684"},{"key":"e_1_2_5_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(03)00831-5"},{"key":"e_1_2_5_22_1","doi-asserted-by":"publisher","DOI":"10.1097\/IAE.0b013e31815e987f"},{"key":"e_1_2_5_23_1","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2007-2591"},{"key":"e_1_2_5_24_1","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2006-1557"},{"key":"e_1_2_5_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(85)33919-2"},{"key":"e_1_2_5_26_1","doi-asserted-by":"crossref","first-page":"612","DOI":"10.1542\/peds.54.5.612","article-title":"Selection of diseases and tests in pediatric screening","volume":"54","author":"Frankenburg WK","year":"1974","journal-title":"Pediatrics"},{"key":"e_1_2_5_27_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.125.11.1562"},{"key":"e_1_2_5_28_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2007.124404"},{"key":"e_1_2_5_29_1","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-129-2-199807150-00012"},{"key":"e_1_2_5_30_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.126.4.493"},{"key":"e_1_2_5_31_1","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1542\/peds.91.5.859","article-title":"Cost\u2010effectiveness of screening and cryotherapy for threshold retinopathy of prematurity","volume":"91","author":"Javitt J","year":"1993","journal-title":"Pediatrics"},{"key":"e_1_2_5_32_1","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2007-3667"},{"key":"e_1_2_5_33_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2008.04.012"},{"key":"e_1_2_5_34_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.80.5.425"},{"key":"e_1_2_5_35_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-009-1077-7"},{"key":"e_1_2_5_36_1","volume-title":"Births: Final Data for 2004","author":"Martin JA","year":"2006"},{"key":"e_1_2_5_37_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2008.138867"},{"key":"e_1_2_5_38_1","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-146-7-200704030-00007"},{"key":"e_1_2_5_39_1","first-page":"268","article-title":"Screening for retinopathy of prematurity employing the retcam 120: sensitivity and specificity","volume":"119","author":"Roth DB","year":"2001","journal-title":"Arch Ophthalmol"},{"key":"e_1_2_5_40_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00246-001-0199-4"},{"key":"e_1_2_5_41_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(99)00003-2"},{"key":"e_1_2_5_42_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2007.09.006"},{"key":"e_1_2_5_43_1","doi-asserted-by":"publisher","DOI":"10.4103\/0301-4738.21612"},{"key":"e_1_2_5_44_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-008-0943-z"},{"key":"e_1_2_5_45_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0929-693X(03)00295-1"},{"key":"e_1_2_5_46_1","doi-asserted-by":"publisher","DOI":"10.1093\/jnci\/djn172"},{"key":"e_1_2_5_47_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2007.10.027"},{"key":"e_1_2_5_48_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.125.11.1523"},{"key":"e_1_2_5_49_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaapos.2006.08.012"},{"key":"e_1_2_5_50_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaapos.2007.04.008"},{"key":"e_1_2_5_51_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaapos.2007.11.022"},{"key":"e_1_2_5_52_1","doi-asserted-by":"publisher","DOI":"10.1542\/peds.102.1.31"},{"key":"e_1_2_5_53_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaapos.2005.11.019"},{"key":"e_1_2_5_54_1","first-page":"145","article-title":"The optimum time to employ telephotoscreening to detect retinopathy of prematurity","volume":"98","author":"Yen KG","year":"2000","journal-title":"Trans Am Ophthalmol Soc"},{"key":"e_1_2_5_55_1","doi-asserted-by":"publisher","DOI":"10.1067\/mpa.2002.121616"}],"container-title":["Acta Ophthalmologica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1755-3768.2009.01715.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1755-3768.2009.01715.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,15]],"date-time":"2023-10-15T20:57:58Z","timestamp":1697403478000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1755-3768.2009.01715.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,4,27]]},"references-count":54,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2010,5]]}},"alternative-id":["10.1111\/j.1755-3768.2009.01715.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1755-3768.2009.01715.x","archive":["Portico"],"relation":{},"ISSN":["1755-375X","1755-3768"],"issn-type":[{"value":"1755-375X","type":"print"},{"value":"1755-3768","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,4,27]]},"assertion":[{"value":"2010-04-27","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}