{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,29]],"date-time":"2025-11-29T23:24:47Z","timestamp":1764458687303},"reference-count":21,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2010,5,26]],"date-time":"2010-05-26T00:00:00Z","timestamp":1274832000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Acta Ophthalmologica"],"published-print":{"date-parts":[[2012,5]]},"abstract":"<jats:title>Abstract.<\/jats:title><jats:p><jats:bold>Purpose:\u2002<\/jats:bold> To investigate the risks of implant exposure after a combined explant\u2013implant procedure in patients with an exposed porous orbital implant.<\/jats:p><jats:p><jats:bold>Methods:\u2002<\/jats:bold> Twenty\u2010four consecutive patients who had a combined explant\u2013implant procedure of an exposed hydroxyapatite (21) or porous polyethylene (3) orbital implant from January 2000 to February 2009 were included. The patient records were reviewed; patients were interviewed by telephone and invited for a clinical examination. Histopathological examination was carried out on the removed implants. Main outcome measures were: presence of exposure of the new implant or not, patient graded satisfaction with the cosmetic result, and presence of poor motility.<\/jats:p><jats:p><jats:bold>Results:\u2002<\/jats:bold> None of the new implants became exposed or infected in the follow\u2010up period of 25 [3\u201394] months (median [range]). The patients scored their satisfaction with the cosmetic result to a median score of 9 (range 5\u201310). Poor motility was present in six of 17 patients. Micro\u2010organisms were identified in three removed implants and signs of inflammation were present in 20 removed implants.<\/jats:p><jats:p><jats:bold>Conclusions:\u2002<\/jats:bold> If a decision of implant removal has been made, it is safe to replace the implant at the same procedure in sockets without profound signs of infection. The procedure carries a possible risk of poor motility.<\/jats:p>","DOI":"10.1111\/j.1755-3768.2010.01914.x","type":"journal-article","created":{"date-parts":[[2010,5,27]],"date-time":"2010-05-27T03:28:24Z","timestamp":1274930904000},"page":"210-214","update-policy":"http:\/\/dx.doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["One\u2010stage explant\u2013implant procedure of exposed porous orbital implants"],"prefix":"10.1111","volume":"90","author":[{"given":"Peter B.","family":"Toft","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marie L.","family":"Roed Rasmussen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jan U.","family":"Prause","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2012,4,27]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(14)74792-0"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2008.09.022"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.iop.0000249432.18688.ee"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(91)32304-2"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(99)90108-2"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.IOP.0000131735.89093.22"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(94)31114-6"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.iop.0000248156.41020.94"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(94)31112-2"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.IOP.0000087029.00333.C2"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1097\/00002341-199903000-00003"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1097\/00002341-199805000-00010"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.2008.01435.x"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1097\/00002341-199805000-00011"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2003.026823"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.125.12.1616"},{"key":"e_1_2_6_18_1","first-page":"177","article-title":"Lack of complications of the hydroxyapatite orbital implant in 250 consecutive cases","volume":"91","author":"Shields CL","year":"1993","journal-title":"Trans Am Ophthalmol Soc"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1440-1606.1999.00160.x"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.IOP.0000129528.16938.1E"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2004.09.030"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2007.06.014"}],"container-title":["Acta Ophthalmologica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1755-3768.2010.01914.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1755-3768.2010.01914.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,31]],"date-time":"2023-10-31T06:38:44Z","timestamp":1698734324000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1755-3768.2010.01914.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,4,27]]},"references-count":21,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2012,5]]}},"alternative-id":["10.1111\/j.1755-3768.2010.01914.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1755-3768.2010.01914.x","archive":["Portico"],"relation":{},"ISSN":["1755-375X","1755-3768"],"issn-type":[{"value":"1755-375X","type":"print"},{"value":"1755-3768","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,4,27]]},"assertion":[{"value":"2012-04-27","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}