{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,7,18]],"date-time":"2024-07-18T02:54:46Z","timestamp":1721271286283},"reference-count":25,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2011,1,25]],"date-time":"2011-01-25T00:00:00Z","timestamp":1295913600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Acta Ophthalmologica"],"published-print":{"date-parts":[[2012,9]]},"abstract":"<jats:title>Abstract.<\/jats:title><jats:p><jats:bold>Purpose:\u2002<\/jats:bold> To evaluate the safety, efficacy, predictability and stability of laser <jats:italic>in situ<\/jats:italic> keratomileusis (LASIK) with a 1000\u2010Hz scanning spot excimer laser (Concept System 1000; WaveLight GmbH, Erlangen, Germany).<\/jats:p><jats:p><jats:bold>Methods:\u2002<\/jats:bold> LASIK was performed on twenty eyes with myopia or myopic astigmatism (mean spherical equivalent refraction: \u22123.97\u2003\u00b1\u20031.72 dioptres (D); mean cylinder: \u22120.84\u2003\u00b1\u20030.77\u2003D) using a microkeratome for flap creation and the Concept System 1000 for photoablation. Patients were examined preoperatively as well as 1, 3 and 6\u2003months after the treatment. Manifest sphere and cylinder, uncorrected (UCDVA) and best corrected (BCDVA) distance visual acuity, corneal topography and pachymetry were analysed.<\/jats:p><jats:p><jats:bold>Results:\u2002<\/jats:bold> We observed no adverse events that might have been associated with the use of a repetition rate of 1000\u2003Hz. All eyes maintained or had improved BCDVA at 6\u2003months after treatment when compared to preoperative values. Six months after LASIK, UCDVA was 20\/20 or better in 85% and 20\/25 or better in 100% of the eyes. The spherical equivalent refraction was within \u00b10.50 D in 95% of the eyes at 6\u2003months after surgery. The refraction stayed stable over time; 95% of the eyes changed &lt;0.5\u2003D postoperatively.<\/jats:p><jats:p><jats:bold>Conclusion:\u2002<\/jats:bold> LASIK with the prototype 1000\u2010Hz excimer laser was safe, efficient and predictable. The postoperative refraction was stable over time. There were no specific clinical side\u2010effects that might be associated with the use of such a high repetition rate.<\/jats:p>","DOI":"10.1111\/j.1755-3768.2010.02052.x","type":"journal-article","created":{"date-parts":[[2011,1,25]],"date-time":"2011-01-25T14:28:26Z","timestamp":1295965706000},"page":"508-513","update-policy":"http:\/\/dx.doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Safety, efficacy, predictability and stability of laser <i>in situ<\/i> keratomileusis (LASIK) with a 1000\u2010Hz scanning spot excimer laser"],"prefix":"10.1111","volume":"90","author":[{"given":"Ramin","family":"Khoramnia","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Josefina P.","family":"Salgado","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian","family":"Wuellner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christof","family":"Donitzky","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chris P.","family":"Lohmann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christoph","family":"Winkler von Mohrenfels","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2011,1,25]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.05.035"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF02181196"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003226-199703000-00007"},{"key":"e_1_2_7_5_1","doi-asserted-by":"crossref","first-page":"28","DOI":"10.3928\/1081-597X-20050101-08","article-title":"Simulation of eye\u2010tracker latency, spot size, and ablation pulse depth on the correction of higher order wavefront aberrations with scanning spot laser systems","volume":"21","author":"Bueeler M","year":"2005","journal-title":"J Refract Surg"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1990.01070070051034"},{"key":"e_1_2_7_7_1","doi-asserted-by":"crossref","first-page":"15","DOI":"10.3928\/1081-597X-20030101-04","article-title":"Effect of beam size on the expected benefit of customized laser refractive surgery","volume":"19","author":"Guirao A","year":"2003","journal-title":"J Refract Surg"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(01)01163-4"},{"key":"e_1_2_7_9_1","doi-asserted-by":"crossref","first-page":"831","DOI":"10.3928\/1081-597X-20041101-12","article-title":"Clinical photoablation with a 500\u2010Hz scanning spot excimer laser","volume":"20","author":"Iseli HP","year":"2004","journal-title":"J Refract Surg"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.01.033"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.01.049"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.02.022"},{"key":"e_1_2_7_13_1","first-page":"208","article-title":"Human excimer laser corneal surgery: preliminary report","volume":"86","author":"L\u2019Esperance FA","year":"1988","journal-title":"Trans Am Ophthalmol Soc"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003226-200107000-00014"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.12.034"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.10.053"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(06)68275-5"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1159\/000309615"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1002\/lsm.20656"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.01.023"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(01)00996-8"},{"key":"e_1_2_7_22_1","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1097\/01.icu.0000233957.88509.2d","article-title":"Advances in refractive surgery: microkeratome and femtosecond laser flap creation in relation to safety, efficacy, predictability, and biomechanical stability","volume":"17","author":"Stonecipher K","year":"2006","journal-title":"Curr Opin Ophthalmol"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(14)71911-7"},{"key":"e_1_2_7_24_1","first-page":"459","article-title":"Standard graphs for reporting refractive surgery","volume":"16","author":"Waring GO","year":"2000","journal-title":"J Refract Surg"},{"key":"e_1_2_7_25_1","first-page":"S565","article-title":"Wavefront\u2010guided laser epithelial keratomileusis with the wavelight concept system 500","volume":"20","author":"Winkler von Mohrenfels C","year":"2004","journal-title":"J Refract Surg"},{"key":"e_1_2_7_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.10.041"}],"container-title":["Acta Ophthalmologica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1755-3768.2010.02052.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1755-3768.2010.02052.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,31]],"date-time":"2023-10-31T02:34:22Z","timestamp":1698719662000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1755-3768.2010.02052.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,1,25]]},"references-count":25,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2012,9]]}},"alternative-id":["10.1111\/j.1755-3768.2010.02052.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1755-3768.2010.02052.x","archive":["Portico"],"relation":{},"ISSN":["1755-375X","1755-3768"],"issn-type":[{"value":"1755-375X","type":"print"},{"value":"1755-3768","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,1,25]]},"assertion":[{"value":"2011-01-25","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}