{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T22:14:24Z","timestamp":1774995264773,"version":"3.50.1"},"reference-count":33,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2010,11,25]],"date-time":"2010-11-25T00:00:00Z","timestamp":1290643200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Acta Ophthalmologica"],"published-print":{"date-parts":[[2011,5]]},"abstract":"<jats:title>Abstract.<\/jats:title><jats:p><jats:bold>Purpose:\u2002<\/jats:bold> To explore the effects of corneal astigmatism and asphericity on posterior elevation values calculated by different reference bodies and to compare their predictive accuracy in the diagnosis of keratoconus.<\/jats:p><jats:p><jats:bold>Methods:\u2002<\/jats:bold> In this prospective observational case series, 44 eyes of 24 patients with keratoconus and 70 eyes of 41 refractive surgery candidates as a control group were measured by the Pentacam Scheimpflug camera. Discriminating ability and predictors of posterior elevation measurements obtained by best fit toric ellipsoid (BFTE) and best fit sphere (BFS) reference surfaces were compared by receiver operator characteristic curves (ROC) and generalized estimating equation (GEE) models. Bland\u2013Altman plots were used to determine the agreement between different reference surfaces.<\/jats:p><jats:p><jats:bold>Results:\u2002<\/jats:bold> Receiver operator characteristic curve analysis showed that posterior elevation measured by a BFTE auto had a significantly higher area under ROC curves (0.99) value than BFTE 8\u2010mm or BFS reference surfaces. ROC analysis identified cut\u2010off values for BFTE auto (9.5\u2010\u03bcm), for BFTE 8\u2010mm (10.5\u2010\u03bcm), for BFS auto (16.5\u2010\u03bcm) and for BFS 8\u2010mm (15.5\u2010\u03bcm) reference surfaces. According to GEE models, corneal cylinder and posterior asphericity had the least effect in toric ellipsoid models. Bland\u2013Altman plots showed a systematic bias at higher values of average posterior elevation measured BFS reference surfaces.<\/jats:p><jats:p><jats:bold>Conclusions:\u2002<\/jats:bold> Posterior corneal elevation value measured by the Pentacam camera can effectively discriminate keratoconus from normal corneas although measured values and cut\u2010off points depend on the selection of reference body and corneal asphericity. Toric ellipsoid reference surface seems to be the most sensitive method to differentiate keratoconus.<\/jats:p>","DOI":"10.1111\/j.1755-3768.2010.02053.x","type":"journal-article","created":{"date-parts":[[2010,11,25]],"date-time":"2010-11-25T10:31:34Z","timestamp":1290681094000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":29,"title":["The role of reference body selection in calculating posterior corneal elevation and prediction of keratoconus using rotating Scheimpflug camera"],"prefix":"10.1111","volume":"89","author":[{"given":"Ill\u00e9s","family":"Kov\u00e1cs","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kata","family":"Mih\u00e1ltz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M\u00f3nika","family":"Ecsedy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J\u00e1nos","family":"N\u00e9meth","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zolt\u00e1n Z","family":"Nagy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2010,11,25]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.06.025"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.ico.0000164831.87593.08"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2006.12.030"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1442-9071.2008.01821.x"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20070501-15"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2007.08.026"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2008.02.020"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1214\/aos\/1176344552"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.06.020"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.02.060"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1093\/aje\/kwf215"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.09.033"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2009.01.009"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0b013e3181915943"},{"key":"e_1_2_6_16_1","first-page":"1551","article-title":"Recent advances in ophthalmic anterior segment imaging: a new era for ophthalmic diagnosis?","volume":"9","author":"Konstantopoulos A","year":"2007","journal-title":"Br J Ophthalmol"},{"key":"e_1_2_6_17_1","first-page":"1099","article-title":"Multivariate approach for quantification of morphologic and functional damage in glaucoma","volume":"41","author":"Martus P","year":"2000","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.ico.0000178728.57435.df"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0b013e31819e34de"},{"key":"e_1_2_6_20_1","first-page":"194","article-title":"Keratoconus detected by videokeratography in candidates for photorefractive keratectomy","volume":"11","author":"Neshburn AB","year":"1995","journal-title":"J Refract Surg"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.11.054"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2006.03.046"},{"key":"e_1_2_6_23_1","doi-asserted-by":"crossref","first-page":"371","DOI":"10.3928\/1081-597X-19950901-14","article-title":"Videokeratographic indices to aid in screening for keratoconus","volume":"11","author":"Rabinowitz YS","year":"1995","journal-title":"J Refract Surg"},{"key":"e_1_2_6_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0039-6257(97)00119-7"},{"key":"e_1_2_6_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(99)00195-9"},{"key":"e_1_2_6_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(02)01121-1"},{"key":"e_1_2_6_27_1","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20090610-06"},{"key":"e_1_2_6_28_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-2005-857908"},{"key":"e_1_2_6_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.12.036"},{"key":"e_1_2_6_30_1","doi-asserted-by":"publisher","DOI":"10.1097\/ICU.0b013e3281ca7121"},{"key":"e_1_2_6_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(00)00159-7"},{"key":"e_1_2_6_32_1","doi-asserted-by":"publisher","DOI":"10.1002\/sim.1114"},{"key":"e_1_2_6_33_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(00)00152-4"},{"key":"e_1_2_6_34_1","doi-asserted-by":"publisher","DOI":"10.2307\/2531734"}],"container-title":["Acta Ophthalmologica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1755-3768.2010.02053.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1755-3768.2010.02053.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,15]],"date-time":"2023-10-15T12:42:08Z","timestamp":1697373728000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1755-3768.2010.02053.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,11,25]]},"references-count":33,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2011,5]]}},"alternative-id":["10.1111\/j.1755-3768.2010.02053.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1755-3768.2010.02053.x","archive":["Portico"],"relation":{},"ISSN":["1755-375X","1755-3768"],"issn-type":[{"value":"1755-375X","type":"print"},{"value":"1755-3768","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,11,25]]},"assertion":[{"value":"2010-11-25","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}