{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,11]],"date-time":"2026-05-11T16:05:54Z","timestamp":1778515554452,"version":"3.51.4"},"reference-count":17,"publisher":"Oxford University Press (OUP)","issue":"6","license":[{"start":{"date-parts":[[2010,11,1]],"date-time":"2010-11-01T00:00:00Z","timestamp":1288569600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2010,11,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Appropriate device selection for transcatheter occlusion of patent ductus arteriosus (PDA) is essential to procedural success.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>To determine if transesophageal echocardiography (TEE) influences device selection for PDA occlusion and to report benefits, limitations, and complications associated with TEE.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Animals<\/jats:title>\n                    <jats:p>Twenty-two client-owned dogs with left-to-right shunting PDA.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>PDA dimensions were obtained via transthoracic echocardiography (TTE) and then TEE followed by angiography. Based solely on information from TTE and angiography, an initial device type and size were selected. After initial device selection, TEE measurements were disclosed and changes in device selection were recorded. After device release, angiography, TEE, or both were performed to assess occlusion.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>An Amplatz canine duct occluder (ACDO) was securely positioned and released in 21 dogs and an embolization coil was deployed in 1 dog. Based on TEE evaluation, initial selected device type was unchanged but ACDO size was changed in 3 dogs. TEE was utilized throughout the procedure allowing real time visualization of device deployment, release and assessment of closure in 17 dogs. No complications occurred related to TEE. Complete PDA closure was achieved in all dogs.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions and Clinical Importance<\/jats:title>\n                    <jats:p>TEE provided anatomic information regarding PDA morphology that closely approximated angiographic ductal dimensions while aiding in device deployment, release and confirmation of closure. We conclude that TEE provides complementary anatomical and intraprocedural information and is well tolerated in dogs.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/j.1939-1676.2010.0587.x","type":"journal-article","created":{"date-parts":[[2010,8,29]],"date-time":"2010-08-29T14:44:40Z","timestamp":1283093080000},"page":"1407-1413","source":"Crossref","is-referenced-by-count":37,"title":["Utility of Transesophageal Echocardiography for Transcatheter Occlusion of Patent Ductus Arteriosus in Dogs: Influence on the Decision-Making Process"],"prefix":"10.1093","volume":"24","author":[{"given":"A.B.","family":"Saunders","sequence":"first","affiliation":[{"name":"College of Veterinary Medicine and Biomedical Sciences, Texas A&M University Department of Small Animal Clinical Sciences and the Michael E. DeBakey Institute for Comparative Cardiovascular Sciences and Biomedical Devices, , College Station, TX 77843-4474"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.E.","family":"Achen","sequence":"additional","affiliation":[{"name":"College of Veterinary Medicine and Biomedical Sciences, Texas A&M University Department of Small Animal Clinical Sciences and the Michael E. DeBakey Institute for Comparative Cardiovascular Sciences and Biomedical Devices, , College Station, TX 77843-4474"},{"name":"Michigan Veterinary Specialists , 29080 Inkster Road, Southfield, MI 48034"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.G.","family":"Gordon","sequence":"additional","affiliation":[{"name":"College of Veterinary Medicine and Biomedical Sciences, Texas A&M University Department of Small Animal Clinical Sciences and the Michael E. DeBakey Institute for Comparative Cardiovascular Sciences and Biomedical Devices, , College Station, TX 77843-4474"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.W.","family":"Miller","sequence":"additional","affiliation":[{"name":"College of Veterinary Medicine and Biomedical Sciences, Texas A&M University Department of Small Animal Clinical Sciences and the Michael E. DeBakey Institute for Comparative Cardiovascular Sciences and Biomedical Devices, , College Station, TX 77843-4474"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2010,11,1]]},"reference":[{"key":"2026020303175035400_b1","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1111\/j.1939-1676.2000.tb02255.x","article-title":"Transcatheter closure of patent ductus arteriosus using occluding spring coils","volume":"14","author":"Stokhof","year":"2000","journal-title":"J Vet Intern Med"},{"key":"2026020303175035400_b2","first-page":"7","article-title":"Catheter closure of patent ductus arteriosus in dogs","volume":"5","author":"Glaus","year":"2003","journal-title":"Variation in ductal size requires different techniques"},{"key":"2026020303175035400_b3","doi-asserted-by":"crossref","first-page":"1348","DOI":"10.1111\/j.1939-1676.2008.0185.x","article-title":"Transarterial ductal occlusion using the Amplatzer\u00ae vascular plug in 30 cases","volume":"22","author":"Achen","year":"2008","journal-title":"J Vet Intern Med"},{"key":"2026020303175035400_b4","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1111\/j.1939-1676.2007.0009.x","article-title":"Minimally invasive per-catheter patent ductus arteriosus occlusion in dogs using a prototype duct occluder","volume":"22","author":"Nguyenba","year":"2008","journal-title":"J Vet Intern Med"},{"key":"2026020303175035400_b5","doi-asserted-by":"crossref","DOI":"10.1016\/j.jvc.2010.04.004","article-title":"Transarterial ductal occlusion using the Amplatz\u00ae canine ductal occluder in 40 dogs","author":"Gordon","year":"2010","journal-title":"J Vet Cardiol"},{"key":"2026020303175035400_b6","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1111\/j.1939-1676.2003.tb02429.x","article-title":"Etiology of patent ductus arteriosus in dogs","volume":"17","author":"Buchanan","year":"2003","journal-title":"J Vet Intern Med"},{"key":"2026020303175035400_b7","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1016\/j.jvc.2006.07.001","article-title":"Angiographic classification of patent ductus arteriosus in the dog","volume":"8","author":"Miller","year":"2006","journal-title":"J Vet Cardiol"},{"key":"2026020303175035400_b8","first-page":"109","article-title":"The Amplatz canine duct occluder","volume":"9","author":"Nguyenba","year":"2007","journal-title":"A novel device for patent ductus arteriosus occlusion"},{"key":"2026020303175035400_b9","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1111\/j.1939-1676.2007.tb02930.x","article-title":"Echocardiographic and angiographic comparison of ductal dimensions in dogs with patent ductus arteriosus","volume":"21","author":"Saunders","year":"2007","journal-title":"J Vet Intern Med"},{"key":"2026020303175035400_b10","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1111\/j.1939-1676.2007.tb02957.x","article-title":"Transthoracic echocardiographic measurement of patent ductus arteriosus in dogs","volume":"21","author":"Schneider","year":"2007","journal-title":"J Vet Intern Med"},{"key":"2026020303175035400_b11","first-page":"197","article-title":"The use of transesophageal echocardiography monitoring of transcatheter closure of a persistent ductus arteriosus","volume":"18","author":"Lam","year":"2001","journal-title":"Echo"},{"key":"2026020303175035400_b12","doi-asserted-by":"crossref","first-page":"1321","DOI":"10.1016\/0002-9149(93)90548-Q","article-title":"Usefulness of transesophageal echocardiography in the pediatric catheterization laboratory","volume":"71","author":"Tumbarello","year":"1993","journal-title":"Am J Cardiol"},{"key":"2026020303175035400_b13","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/S1760-2734(06)70062-5","article-title":"Use of transesophageal echocardiography for visualization of the patent ductus arteriosus during transcatheter coil embolization","volume":"6","author":"Pariaut","year":"2004","journal-title":"J Vet Cardiol"},{"key":"2026020303175035400_b14","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1053\/j.ctsap.2005.05.008","article-title":"Transarterial coil embolization for canine patent ductus arteriosus occlusion","volume":"10","author":"Gordon","year":"2005","journal-title":"Clin Tech Small Anim Pract"},{"key":"2026020303175035400_b15","first-page":"15","article-title":"Grossman's Cardiac Catheterization, Angiography, and Intervention","author":"Baim","year":"2000","edition":"6th ed"},{"key":"2026020303175035400_b16","first-page":"488","article-title":"Transesophageal echocardiography in neonates, infants and children","volume":"68","author":"Scott","year":"1992","journal-title":"Applicability and diagnostic value in everyday practice of a cardiothoracic unit"},{"key":"2026020303175035400_b17","first-page":"379","article-title":"Upper gastrointestinal injuries related to perioperative transesophageal echocardiography","volume":"20","author":"Augoustides","year":"2006","journal-title":"Index case, literature review, classification proposal, and call for a registry"}],"container-title":["Journal of Veterinary Internal Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1939-1676.2010.0587.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/academic.oup.com\/jvim\/article-pdf\/24\/6\/1407\/66654932\/j.1939-1676.2010.0587.x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jvim\/article-pdf\/24\/6\/1407\/66654932\/j.1939-1676.2010.0587.x.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,3]],"date-time":"2026-02-03T08:18:03Z","timestamp":1770106683000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jvim\/article\/24\/6\/1407\/8447403"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,11,1]]},"references-count":17,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2010,11,1]]}},"URL":"https:\/\/doi.org\/10.1111\/j.1939-1676.2010.0587.x","relation":{},"ISSN":["1939-1676"],"issn-type":[{"value":"1939-1676","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2010,11]]},"published":{"date-parts":[[2010,11,1]]}}}