{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T04:42:14Z","timestamp":1789965734290,"version":"4.0.1"},"reference-count":44,"publisher":"Wiley","issue":"9","license":[{"start":{"date-parts":[[2017,6,23]],"date-time":"2017-06-23T00:00:00Z","timestamp":1498176000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Cardiovasc electrophysiol"],"published-print":{"date-parts":[[2017,9]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Introduction<\/jats:title><jats:p>CF\u2010sensing catheter emerged as a novel ablation technology and was increasingly used in clinical practice. Nonetheless, available evidence of efficacy and safety comparison between CF\u2010guided RF catheter ablation and non\u2010CF\u2010guided ablation for treatment of AF was still lacking.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods and results<\/jats:title><jats:p>Twenty\u2010two eligible studies were included after systematic review through the MEDLINE, Google Scholar, the Cochrane Library and PubMed databases. AF\/atrial tachycardia\u2010free survival was markedly improved in CF\u2010guided catheter ablation compared with non\u2010CF\u2010guided ablation at a median 12\u2010month follow\u2010up (RR: 1.12, 95% CI: 1.06\u20131.19, P = 0.000, fixed). Notably, CF\u2010guided catheter ablation presented a robust survival benefit for treatment of paroxysmal AF (RR: 1.10, 95% CI: 1.03\u20131.18, P = 0.005, fixed), but not persistent AF (RR: 1.07, 95% CI: 0.89\u20131.28, P = 0.466, fixed). Moreover, procedure time (WMD: \u221223.87, 95% CI: \u221233.83 to \u221213.91, P = 0.000, random), fluoroscopy time (WMD: \u22127.78, 95% CI: \u221213.93 to \u22121.63, P = 0.013, random) and RF time (WMD: \u22123.98, 95% CI: \u22127.78 to \u22120.17, P = 0.040, random) were significantly reduced in CF\u2010guided catheter ablation. The incidence of procedure\u2010related complications did not differ between these two technologies (RR: 0.83, 95% CI: 0.59 to 1.16, P = 0.271, fixed).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>CF\u2010guided RF catheter ablation was associated with a significant AF\/atrial tachycardia\u2010free survival benefit compared with non\u2010CF\u2010guided ablation in patients with paroxysmal AF rather than persistent AF. In addition, CF\u2010guided ablation strategy also reduced the procedure time, fluoroscopy time, as well as RF time despite no distinct effect on the alleviation of procedure\u2010related complications.<\/jats:p><\/jats:sec>","DOI":"10.1111\/jce.13264","type":"journal-article","created":{"date-parts":[[2017,6,1]],"date-time":"2017-06-01T10:12:43Z","timestamp":1496311963000},"page":"994-1005","source":"Crossref","is-referenced-by-count":33,"title":["Role of contact force\u2010guided radiofrequency catheter ablation for treatment of atrial fibrillation: A systematic review and meta\u2010analysis"],"prefix":"10.1111","volume":"28","author":[{"given":"Hui","family":"Lin","sequence":"first","affiliation":[{"name":"Department of Respiratory The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University  Wenzhou China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi\u2010He","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Cardiology Xinhua Hospital affiliated to the Medical School of Shanghai Jiaotong University  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jian\u2010Wen","family":"Hou","sequence":"additional","affiliation":[{"name":"Department of Cardiology Xinhua Hospital affiliated to the Medical School of Shanghai Jiaotong University  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhao\u2010Yang","family":"Lu","sequence":"additional","affiliation":[{"name":"Department of Cardiology Xinhua Hospital affiliated to the Medical School of Shanghai Jiaotong University  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yin","family":"Xiang","sequence":"additional","affiliation":[{"name":"Department of Cardiology Xinhua Hospital affiliated to the Medical School of Shanghai Jiaotong University  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5413-9265","authenticated-orcid":false,"given":"Yi\u2010Gang","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Cardiology Xinhua Hospital affiliated to the Medical School of Shanghai Jiaotong University  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2017,6,23]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2014.03.022"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehw210"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/eus027"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.110.946806"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2010.05.061"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.0000091081.19465.F1"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.0000151289.73085.36"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.2009.01693.x"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.2010.01750.x"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.110.959429"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.108.803650"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euv057"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.114.014092"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.5114\/aoms.2014.42578"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euv206"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2016.05.011"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10840-015-0056-7"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.2007.00956.x"},{"key":"e_1_2_8_20_1","doi-asserted-by":"publisher","DOI":"10.1586\/14779072.2016.1168695"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.113.001094"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1097\/HCO.0000000000000131"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.113.978320"},{"key":"e_1_2_8_24_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.113.000374"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2014.04.072"},{"key":"e_1_2_8_26_1","doi-asserted-by":"publisher","DOI":"10.1111\/jce.12606"},{"key":"e_1_2_8_27_1","doi-asserted-by":"publisher","DOI":"10.1111\/pace.12549"},{"key":"e_1_2_8_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2014.04.020"},{"key":"e_1_2_8_29_1","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehw260"},{"key":"e_1_2_8_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcard.2014.11.105"},{"key":"e_1_2_8_31_1","doi-asserted-by":"publisher","DOI":"10.5603\/CJ.a2013.0153"},{"key":"e_1_2_8_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2014.03.019"},{"key":"e_1_2_8_33_1","doi-asserted-by":"publisher","DOI":"10.1111\/pace.12811"},{"key":"e_1_2_8_34_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10840-016-0128-3"},{"key":"e_1_2_8_35_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2012.03503.x"},{"key":"e_1_2_8_36_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00392-015-0855-y"},{"key":"e_1_2_8_37_1","doi-asserted-by":"publisher","DOI":"10.1111\/pace.12501"},{"key":"e_1_2_8_38_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00392-013-0625-7"},{"key":"e_1_2_8_39_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2014.07.033"},{"key":"e_1_2_8_40_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ipej.2015.07.004"},{"key":"e_1_2_8_41_1","doi-asserted-by":"publisher","DOI":"10.1111\/jce.13058"},{"key":"e_1_2_8_42_1","doi-asserted-by":"publisher","DOI":"10.1111\/jce.12303"},{"key":"e_1_2_8_43_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10840-015-0006-4"},{"key":"e_1_2_8_44_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euv186"},{"key":"e_1_2_8_45_1","first-page":"193","article-title":"Which is the best catheter to perform atrial fibrillation ablation? A comparison between standard ThermoCool, SmartTouch, and Surround Flow catheters","volume":"39","author":"Sciarra L","year":"2014","journal-title":"J Interv Card Electrophysiol"}],"container-title":["Journal of Cardiovascular Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fjce.13264","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jce.13264","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,2]],"date-time":"2023-10-02T15:20:37Z","timestamp":1696260037000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jce.13264"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,6,23]]},"references-count":44,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2017,9]]}},"alternative-id":["10.1111\/jce.13264"],"URL":"https:\/\/doi.org\/10.1111\/jce.13264","archive":["Portico"],"relation":{},"ISSN":["1045-3873","1540-8167"],"issn-type":[{"value":"1045-3873","type":"print"},{"value":"1540-8167","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,6,23]]}}}