{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,20]],"date-time":"2026-07-20T05:28:44Z","timestamp":1784525324600,"version":"3.55.0"},"reference-count":11,"publisher":"Wiley","issue":"9","license":[{"start":{"date-parts":[[2019,6,25]],"date-time":"2019-06-25T00:00:00Z","timestamp":1561420800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Cardiovasc electrophysiol"],"published-print":{"date-parts":[[2019,9]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Introduction<\/jats:title><jats:p>Emerging medical technology has allowed for monitoring of heart rhythm abnormalities using smartphone compatible devices. The safety and utility of such devices have not been established in patients with cardiac implantable electronic devices (CIEDs). We sought to assess the safety and compatibility of the Food and Drug Administration\u2010approved AliveCor Kardia device in patients with CIEDs.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods and Results<\/jats:title><jats:p>We prospectively recruited patients with CIED for a Kardia recording during their routine device interrogation. A recording was obtained in paced and nonpaced states. Adverse clinical events were noted at the time of recording. Electrograms (EGMs) from the cardiac device were obtained at the time of recording to assess for any electromagnetic interference (EMI) introduced by Kardia. Recordings were analyzed for quality and given a score of 3 (interpretable rhythm, no noise), 2 (interpretable rhythm, significant noise) or 1 (uninterpretable). A total of 251 patients were recruited (59% with a pacemaker and 41% with ICD). There were no adverse clinical events noted at the time of recording and no changes to CIED settings. Review of all EGMs revealed no EMI introduced by Kardia. Recordings were correctly interpreted in 90% of paced recordings (183 had a score of 3, 43 of 2, and 25 of 1) and 94.7% of nonpaced recordings (147 of 3, 15 of 2, and 9 of 1).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The AliveCor Kardia device has an excellent safety profile when used in conjunction with most CIEDs. The quality of recordings was preserved in this population. The device, therefore, can be considered for heart rhythm monitoring in patients with CIEDs.<\/jats:p><\/jats:sec>","DOI":"10.1111\/jce.14024","type":"journal-article","created":{"date-parts":[[2019,6,13]],"date-time":"2019-06-13T04:44:35Z","timestamp":1560401075000},"page":"1602-1609","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Safety and compatibility of smart device heart rhythm monitoring in patients with cardiovascular implantable electronic devices"],"prefix":"10.1111","volume":"30","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9515-1359","authenticated-orcid":false,"given":"Anas A.","family":"Abudan","sequence":"first","affiliation":[{"name":"Division of Cardiovascular Diseases Mayo Clinic Rochester Minnesota"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ameesh","family":"Isath","sequence":"additional","affiliation":[{"name":"Division of Cardiovascular Diseases Mayo Clinic Rochester Minnesota"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James D.","family":"Ryan","sequence":"additional","affiliation":[{"name":"Division of Cardiovascular Diseases Mayo Clinic Rochester Minnesota"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark J.","family":"Henrich","sequence":"additional","affiliation":[{"name":"Division of Cardiovascular Diseases Mayo Clinic Rochester Minnesota"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jennifer L.","family":"Dugan","sequence":"additional","affiliation":[{"name":"Division of Cardiovascular Diseases Mayo Clinic Rochester Minnesota"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zachi I.","family":"Attia","sequence":"additional","affiliation":[{"name":"Division of Cardiovascular Diseases Mayo Clinic Rochester Minnesota"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dorothy J.","family":"Ladewig","sequence":"additional","affiliation":[{"name":"Mayo Clinic Ventures Mayo Clinic Rochester Minnesota"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John J.","family":"Dillon","sequence":"additional","affiliation":[{"name":"Division of Nephrology and Hypertension Mayo Clinic Rochester Minnesota"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5052-2948","authenticated-orcid":false,"given":"Paul A.","family":"Friedman","sequence":"additional","affiliation":[{"name":"Division of Cardiovascular Diseases Mayo Clinic Rochester Minnesota"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2019,6,25]]},"reference":[{"key":"e_1_2_8_1_2_1","unstructured":"SmithA(2017).Record shares of Americans now own smartphones have home broadband Pew Research Center. Available from:http:\/\/www.pewresearch.org\/fact\u2010tank\/2017\/01\/12\/evolution\u2010of\u2010technology\/. Accessed 3 June 2018."},{"key":"e_1_2_8_1_3_1","unstructured":"Projected wearables unit shipments worldwide 2014\u20102022. Available from:https:\/\/www.statista.com\/statistics\/296565\/wearables\u2010worldwide\u2010shipments\/. Accessed 3 June 2018."},{"key":"e_1_2_8_1_4_1","unstructured":"AliveCor: FDA and CE Approval. Available from:https:\/\/alivecor.zendesk.com\/hc\/en\u2010us\/articles\/115015799808\u2010Is\u2010Kardia\u2010FDA\u2010cleared\u2010and\u2010CE\u2010marked. Accessed 3 June 2018."},{"key":"e_1_2_8_1_5_1","unstructured":"AliveCor: mHealth for iHumans. AliveCor Inc. Available from:https:\/\/storealivecorcom\/products\/kardiamobile. Accessed 3 June 2018."},{"key":"e_1_2_8_1_6_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2011.03150.x"},{"key":"e_1_2_8_1_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2014.11.015"},{"key":"e_1_2_8_1_8_1","doi-asserted-by":"publisher","DOI":"10.3389\/fpsyg.2015.02013"},{"key":"e_1_2_8_1_9_1","doi-asserted-by":"publisher","DOI":"10.2196\/cardio.8710"},{"key":"e_1_2_8_1_10_1","doi-asserted-by":"publisher","DOI":"10.4022\/jafib.1546"},{"key":"e_1_2_8_1_11_1","doi-asserted-by":"publisher","DOI":"10.7717\/peerj.1554"},{"key":"e_1_2_8_1_12_1","doi-asserted-by":"publisher","DOI":"10.1160\/TH14-03-0231"}],"container-title":["Journal of Cardiovascular Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jce.14024","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/jce.14024","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jce.14024","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,9]],"date-time":"2023-09-09T20:47:14Z","timestamp":1694292434000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jce.14024"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,6,25]]},"references-count":11,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2019,9]]}},"alternative-id":["10.1111\/jce.14024"],"URL":"https:\/\/doi.org\/10.1111\/jce.14024","archive":["Portico"],"relation":{},"ISSN":["1045-3873","1540-8167"],"issn-type":[{"value":"1045-3873","type":"print"},{"value":"1540-8167","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,6,25]]},"assertion":[{"value":"2019-01-16","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-06-05","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-06-25","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}