{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T17:21:35Z","timestamp":1790788895748,"version":"4.1.0"},"reference-count":14,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2020,1,10]],"date-time":"2020-01-10T00:00:00Z","timestamp":1578614400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Cardiovasc electrophysiol"],"published-print":{"date-parts":[[2020,2]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Introduction<\/jats:title><jats:p>Late lead perforation (LLP), defined as perforation \u226530 days from cardiac implantable electronic device implant, is a rare diagnosis and little data exist regarding management practices and outcomes. The purpose of this study was to evaluate the occurrence, safety, and efficacy of transvenous management of clinically significant LLP.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>The electronic medical records of a single\u2010center tertiary hospital were reviewed for all patients who were referred for LLP or its sequelae.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Eleven consecutive patients were identified from October 2011 to December 2018 with clinically significant LLP. Patients most often presented with pericardial symptoms with the exception of one asymptomatic patient. The median time from lead implant to intervention for LLP was 246 days. Nine patients were managed with an initial transvenous approach, with one requiring sternotomy (lead 6.3 years old). Two patients had a surgical approach, one performed at an outside hospital with subsequent death and another had a mini\u2010thoracotomy, but the lead was removed percutaneously with no surgical repair. In this small cohort, there was no association between the lead extending beyond the parietal pericardium and surgical repair (<jats:italic>P<\/jats:italic>\u2009=\u2009.99).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Our single\u2010center experience suggests that LLP can be initially managed with a cautious transvenous approach in most patients, but intraprocedural ultrasound for pericardial monitoring and a rescue plan with immediate surgical back up is mandatory.<\/jats:p><\/jats:sec>","DOI":"10.1111\/jce.14331","type":"journal-article","created":{"date-parts":[[2020,1,7]],"date-time":"2020-01-07T05:59:08Z","timestamp":1578376748000},"page":"521-528","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Transvenous management of cardiac implantable electronic device late lead perforation"],"prefix":"10.1111","volume":"31","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0548-9047","authenticated-orcid":false,"given":"Peter M.","family":"Jessel","sequence":"first","affiliation":[{"name":"Knight Cardiovascular Institute Oregon Health &amp; Science University Hospital  Portland Oregon"},{"name":"Division of Cardiology VA Portland Health Care System  Portland Oregon"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mrinal","family":"Yadava","sequence":"additional","affiliation":[{"name":"Knight Cardiovascular Institute Oregon Health &amp; Science University Hospital  Portland Oregon"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4078-9064","authenticated-orcid":false,"given":"Babak","family":"Nazer","sequence":"additional","affiliation":[{"name":"Knight Cardiovascular Institute Oregon Health &amp; Science University Hospital  Portland Oregon"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas A.","family":"Dewland","sequence":"additional","affiliation":[{"name":"Knight Cardiovascular Institute Oregon Health &amp; Science University Hospital  Portland Oregon"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jared","family":"Miller","sequence":"additional","affiliation":[{"name":"Knight Cardiovascular Institute Oregon Health &amp; Science University Hospital  Portland Oregon"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric C.","family":"Stecker","sequence":"additional","affiliation":[{"name":"Knight Cardiovascular Institute Oregon Health &amp; Science University Hospital  Portland Oregon"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Castigliano M.","family":"Bhamidipati","sequence":"additional","affiliation":[{"name":"Knight Cardiovascular Institute Oregon Health &amp; Science University Hospital  Portland Oregon"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Howard K.","family":"Song","sequence":"additional","affiliation":[{"name":"Knight Cardiovascular Institute Oregon Health &amp; Science University Hospital  Portland Oregon"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charles A.","family":"Henrikson","sequence":"additional","affiliation":[{"name":"Knight Cardiovascular Institute Oregon Health &amp; Science University Hospital  Portland Oregon"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2020,1,10]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1111\/pace.12472"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/eun363"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2007.00575.x"},{"key":"e_1_2_9_5_1","first-page":"3242891","article-title":"Surgical repair of subacute right ventricular perforation after pacemaker implantation","volume":"2017","author":"Oda T","year":"2017","journal-title":"Case Rep Cardiol"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2017.09.001"},{"key":"e_1_2_9_7_1","first-page":"442","article-title":"Subacute right ventricular pacemaker lead perforation: Often talked about in consent forms but very rarely seen","volume":"2","author":"Welch AR","year":"2011","journal-title":"J Innovations Cardiac Rhythm Manag"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.106.669630"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/pace.12301"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrcr.2018.06.015"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.117.006107"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2006.00385.x"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.119.007278"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2004.05.011"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1002\/clc.20803"}],"container-title":["Journal of Cardiovascular Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fjce.14331","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jce.14331","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/jce.14331","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jce.14331","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,7]],"date-time":"2023-09-07T14:30:01Z","timestamp":1694097001000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jce.14331"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,1,10]]},"references-count":14,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020,2]]}},"alternative-id":["10.1111\/jce.14331"],"URL":"https:\/\/doi.org\/10.1111\/jce.14331","archive":["Portico"],"relation":{},"ISSN":["1045-3873","1540-8167"],"issn-type":[{"value":"1045-3873","type":"print"},{"value":"1540-8167","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,1,10]]},"assertion":[{"value":"2019-10-23","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-12-07","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-01-10","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}