{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,15]],"date-time":"2026-01-15T13:30:40Z","timestamp":1768483840522,"version":"3.49.0"},"reference-count":38,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2020,3,9]],"date-time":"2020-03-09T00:00:00Z","timestamp":1583712000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Cardiovasc electrophysiol"],"published-print":{"date-parts":[[2020,5]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Introduction<\/jats:title><jats:p>Interactions of left ventricular assist devices (LVADs) with transvenous implantable cardioverter\u2010defibrillator systems (ICDs) have been widely reported. However, less is known regarding the impact of electromagnetic interference (EMI) from LVADs on subcutaneous ICD function.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods and Results<\/jats:title><jats:p>A comprehensive literature search was performed on PubMed, Cochrane central registry, and Google Scholar using the search terms \u201csubcutaneous implantable cardioverter\u2010defibrillator and left ventricular assist devices,\u201d \u201celectromagnetic interference, LVAD, and subcutaneous ICD,\u201d \u201cEMI and S\u2010ICD,\u201d and \u201cinappropriate shocks, LVAD, and ICD.\u201d Demographic and programming data were extracted from the reports and authors as needed. A total of seven cases of EMI in LVAD patients with subcutaneous ICD (S\u2010ICD) devices were found. In addition three previously unreported cases from our center were included. All cases involved either a heartware ventricular assist device or HeartMate III LVAD with a pre\u2010existing S\u2010ICD. In all patients, both the primary and secondary vectors had inappropriate sensing due to EMI. Three patients were reprogramed to the alternate vector with appropriate sensing. The S\u2010ICD was either inactivated or replaced with a transvenous device in six patients. A single patient was left sensing in the alternate vector. There were no reports of inability to interrogate S\u2010ICD systems in patients with LVADs.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The risk of inappropriate shocks from LVADs should be considered in pre\u2010existing patients with S\u2010ICD, particularly when the heartware ventricular assist device or HeartMate III LVAD device is present. Reprogramming of the sensing vector can occasionally avoid this issue but often the S\u2010ICD needs to be inactivated.<\/jats:p><\/jats:sec>","DOI":"10.1111\/jce.14431","type":"journal-article","created":{"date-parts":[[2020,3,4]],"date-time":"2020-03-04T04:12:52Z","timestamp":1583295172000},"page":"1195-1201","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":22,"title":["Electromagnetic interference from left ventricular assist devices in patients with subcutaneous implantable cardioverter\u2010defibrillators"],"prefix":"10.1111","volume":"31","author":[{"given":"Yuji","family":"Ishida","sequence":"first","affiliation":[{"name":"Division of Cardiology Medical University of South Carolina  Charleston South Carolina"},{"name":"Department of Cardiology Hirosaki University Graduate School of Medicine  Hirosaki Aomori Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joshua E.","family":"Payne","sequence":"additional","affiliation":[{"name":"Division of Cardiology Medical University of South Carolina  Charleston South Carolina"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael E.","family":"Field","sequence":"additional","affiliation":[{"name":"Division of Cardiology Medical University of South Carolina  Charleston South Carolina"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4579-0216","authenticated-orcid":false,"given":"Michael R.","family":"Gold","sequence":"additional","affiliation":[{"name":"Division of Cardiology Medical University of South Carolina  Charleston South Carolina"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2020,3,9]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2015.02.047"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2017.05.016"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/jce.12705"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10840-015-0093-2"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.healun.2017.07.005"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2017.06.040"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2019.04.048"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cardfail.2018.07.423"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacep.2018.04.014"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.113.000240"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.116.004633"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1111\/pace.13273"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1111\/jce.13433"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacep.2018.05.002"},{"key":"e_1_2_7_16_1","first-page":"1","article-title":"Subcutaneous implantable cardioverter defibrillators in patients with left ventricular assist devices: case report and comprehensive review","volume":"3","author":"L\u00f3pez\u2010Gil M","year":"2019","journal-title":"Eur Hear J \u2010 Case Reports"},{"key":"e_1_2_7_17_1","doi-asserted-by":"crossref","unstructured":"StilesMK FauchierL MorilloCA et al.2019HRS\/EHRA\/APHRS\/LAHRS focused update to 2015 expert consensus statement on optimal implantable cardioverter\u2010de fi brillator programming and testing.Heart Rhythm. 2019 May 14. pii: S1547\u20105271(19)30208\u20105.","DOI":"10.1002\/joa3.12178"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2018.05.011"},{"key":"e_1_2_7_19_1","unstructured":"https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfMAUDE\/TextSearch.cfm. Accessed 12\/10\/2019."},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2012.03370.x"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.2007.00805.x"},{"key":"e_1_2_7_22_1","first-page":"1613","volume-title":"J Am Coll Cardiol","author":"Mehta R","year":"2008"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2009.02419.x"},{"key":"e_1_2_7_24_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2009.02455.x"},{"key":"e_1_2_7_25_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10840-009-9415-6"},{"key":"e_1_2_7_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2008.02.072"},{"key":"e_1_2_7_27_1","doi-asserted-by":"publisher","DOI":"10.1510\/icvts.2009.202077"},{"key":"e_1_2_7_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2009.09.044"},{"key":"e_1_2_7_29_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10840-013-9854-y"},{"key":"e_1_2_7_30_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00399-017-0509-z"},{"key":"e_1_2_7_31_1","doi-asserted-by":"publisher","DOI":"10.1111\/pace.13210"},{"key":"e_1_2_7_32_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2009.02403.x"},{"key":"e_1_2_7_33_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2010.11.026"},{"key":"e_1_2_7_34_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAT.0b013e318285fe93"},{"key":"e_1_2_7_35_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcard.2015.05.135"},{"key":"e_1_2_7_36_1","doi-asserted-by":"publisher","DOI":"10.1111\/anec.12181"},{"key":"e_1_2_7_37_1","first-page":"2013","article-title":"Subcutaneous implantable cardioverter\u2010defibrillator implantation in a patient with a left ventricular assist device already in place","volume":"42","author":"Gupta A","year":"2015","journal-title":"Tex Hear Inst J."},{"key":"e_1_2_7_38_1","doi-asserted-by":"publisher","DOI":"10.14503\/THIJ-14-4795"},{"key":"e_1_2_7_39_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacep.2015.10.008"}],"container-title":["Journal of Cardiovascular Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jce.14431","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/jce.14431","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jce.14431","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,6]],"date-time":"2023-09-06T21:49:14Z","timestamp":1694036954000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jce.14431"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,3,9]]},"references-count":38,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2020,5]]}},"alternative-id":["10.1111\/jce.14431"],"URL":"https:\/\/doi.org\/10.1111\/jce.14431","archive":["Portico"],"relation":{},"ISSN":["1045-3873","1540-8167"],"issn-type":[{"value":"1045-3873","type":"print"},{"value":"1540-8167","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,3,9]]},"assertion":[{"value":"2019-11-03","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-02-19","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-03-09","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}