{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T11:25:45Z","timestamp":1740137145012,"version":"3.37.3"},"reference-count":6,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2020,11,25]],"date-time":"2020-11-25T00:00:00Z","timestamp":1606262400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/501100008667","name":"SENSHIN Medical Research Foundation","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100008667","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100005865","name":"Mochida Memorial Foundation for Medical and Pharmaceutical Research","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100005865","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Cardiovasc electrophysiol"],"published-print":{"date-parts":[[2021,1]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Mitral isthmus (MI) ablation is commonly performed as an adjunct therapy to pulmonary isolation during the treatment for persistent atrial fibrillation. Confirmation of complete MI block is essential because an incomplete MI block may result in iatrogenic atrial tachycardia. However, there are several pitfalls in the diagnosis of an MI line block. We herein report a case of transient pause\u2010dependent MI block during MI ablation.<\/jats:p>","DOI":"10.1111\/jce.14819","type":"journal-article","created":{"date-parts":[[2020,11,18]],"date-time":"2020-11-18T22:27:35Z","timestamp":1605738455000},"page":"162-165","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Pause\u2010dependent mitral isthmus conduction block during ablation of the mitral isthmus: What is the mechanism?"],"prefix":"10.1111","volume":"32","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2964-2544","authenticated-orcid":false,"given":"Tsukasa","family":"Kamakura","sequence":"first","affiliation":[{"name":"Department of Cardiac Pacing and Electrophysiology, IHC, Liryc, Electrophysiology and Heart modeling Institute, Bordeaux University Hospital (CHU) University of Bordeaux  Pessac\u2010Bordeaux France"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Remi","family":"Chauvel","sequence":"additional","affiliation":[{"name":"Department of Cardiac Pacing and Electrophysiology, IHC, Liryc, Electrophysiology and Heart modeling Institute, Bordeaux University Hospital (CHU) University of Bordeaux  Pessac\u2010Bordeaux France"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Josselin","family":"Duchateau","sequence":"additional","affiliation":[{"name":"Department of Cardiac Pacing and Electrophysiology, IHC, Liryc, Electrophysiology and Heart modeling Institute, Bordeaux University Hospital (CHU) University of Bordeaux  Pessac\u2010Bordeaux France"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nicolas","family":"Derval","sequence":"additional","affiliation":[{"name":"Department of Cardiac Pacing and Electrophysiology, IHC, Liryc, Electrophysiology and Heart modeling Institute, Bordeaux University Hospital (CHU) University of Bordeaux  Pessac\u2010Bordeaux France"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas","family":"Pambrun","sequence":"additional","affiliation":[{"name":"Department of Cardiac Pacing and Electrophysiology, IHC, Liryc, Electrophysiology and Heart modeling Institute, Bordeaux University Hospital (CHU) University of Bordeaux  Pessac\u2010Bordeaux France"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2020,11,25]]},"reference":[{"key":"e_1_2_4_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2009.06.025"},{"key":"e_1_2_4_3_1","doi-asserted-by":"publisher","DOI":"10.1378\/chest.63.5.678"},{"key":"e_1_2_4_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2006.09.015"},{"key":"e_1_2_4_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-0736(88)80027-X"},{"key":"e_1_2_4_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2011.11.041"},{"key":"e_1_2_4_7_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.109.893107"}],"container-title":["Journal of Cardiovascular Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jce.14819","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/jce.14819","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jce.14819","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,21]],"date-time":"2023-08-21T22:31:06Z","timestamp":1692657066000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jce.14819"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,11,25]]},"references-count":6,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,1]]}},"alternative-id":["10.1111\/jce.14819"],"URL":"https:\/\/doi.org\/10.1111\/jce.14819","archive":["Portico"],"relation":{},"ISSN":["1045-3873","1540-8167"],"issn-type":[{"type":"print","value":"1045-3873"},{"type":"electronic","value":"1540-8167"}],"subject":[],"published":{"date-parts":[[2020,11,25]]},"assertion":[{"value":"2020-09-19","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-11-15","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-11-25","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}