{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,8]],"date-time":"2026-01-08T00:20:04Z","timestamp":1767831604560,"version":"3.49.0"},"reference-count":6,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2022,12,16]],"date-time":"2022-12-16T00:00:00Z","timestamp":1671148800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Cardiovasc electrophysiol"],"published-print":{"date-parts":[[2023,1]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Intrinsic antitachycardia pacing (iATP) is a novel automated ventricular ATP algorithm that designs ATP sequences based on the analysis of prior failed ATP. Real\u2010world data on the efficacy and safety of iATP are lacking. Among 124 ventricular tachycardia (VT) episodes in 130 consecutive patients (mean age at implantation: 63.8\u2009\u00b1\u200914.9 years; sex, 95 male and 35 female) for whom implantable cardioverter defibrillator or cardiac resynchronization therapy defibrillator equipped with iATP algorithm was implanted, we investigated the efficacy and safety of iATP for VT refractory to conventional burst pacing.\u00a0Eight patients had a total of 17 episodes of iATP therapy after failed conventional burst pacing within 11.2\u2009\u00b1\u20096.6 months of follow\u2010up. Eleven VT episodes (64.7%) in seven patients (87.5%) were successfully terminated by iATP, and only one patient (12.5%) experienced VT acceleration.\u00a0iATP might be useful for VTs refractory to conventional burst pacing with a low risk of VT acceleration.<\/jats:p>","DOI":"10.1111\/jce.15773","type":"journal-article","created":{"date-parts":[[2022,12,13]],"date-time":"2022-12-13T12:36:50Z","timestamp":1670935010000},"page":"225-228","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Efficacy of intrinsic antitachycardia pacing for ventricular tachycardia refractory to conventional burst pacing: A case series"],"prefix":"10.1111","volume":"34","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2964-2544","authenticated-orcid":false,"given":"Tsukasa","family":"Kamakura","sequence":"first","affiliation":[{"name":"Division of Arrhythmia and Electrophysiology, Department of Cardiovascular Medicine National Cerebral and Cardiovascular Center  Osaka Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nobuhiko","family":"Ueda","sequence":"additional","affiliation":[{"name":"Division of Arrhythmia and Electrophysiology, Department of Cardiovascular Medicine National Cerebral and Cardiovascular Center  Osaka Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mitsuru","family":"Wada","sequence":"additional","affiliation":[{"name":"Division of Arrhythmia and Electrophysiology, Department of Cardiovascular Medicine National Cerebral and Cardiovascular Center  Osaka Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kohei","family":"Ishibashi","sequence":"additional","affiliation":[{"name":"Division of Arrhythmia and Electrophysiology, Department of Cardiovascular Medicine National Cerebral and Cardiovascular Center  Osaka Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kengo","family":"Kusano","sequence":"additional","affiliation":[{"name":"Division of Arrhythmia and Electrophysiology, Department of Cardiovascular Medicine National Cerebral and Cardiovascular Center  Osaka Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2022,12,16]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2020.05.009"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ipej.2021.06.004"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ipej.2022.01.001"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrcr.2022.07.017"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrcr.2021.11.026"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.116.004823"}],"container-title":["Journal of Cardiovascular Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jce.15773","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/jce.15773","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jce.15773","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,19]],"date-time":"2023-08-19T12:17:35Z","timestamp":1692447455000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jce.15773"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12,16]]},"references-count":6,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2023,1]]}},"alternative-id":["10.1111\/jce.15773"],"URL":"https:\/\/doi.org\/10.1111\/jce.15773","archive":["Portico"],"relation":{},"ISSN":["1045-3873","1540-8167"],"issn-type":[{"value":"1045-3873","type":"print"},{"value":"1540-8167","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,12,16]]},"assertion":[{"value":"2022-10-21","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-12-06","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-12-16","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}