{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T03:50:15Z","timestamp":1791949815524,"version":"4.3.4"},"reference-count":12,"publisher":"Wiley","issue":"10","license":[{"start":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T00:00:00Z","timestamp":1788825600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T00:00:00Z","timestamp":1788825600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"funder":[{"DOI":"10.13039\/100007497","name":"Biosense Webster","doi-asserted-by":"publisher","award":["C2304900"],"award-info":[{"award-number":["C2304900"]}],"id":[{"id":"10.13039\/100007497","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100007225","name":"Ministry of Science and Technology","doi-asserted-by":"publisher","award":["NSTC 113\u20102628\u2010B\u2010075\u2010003\u2010MY3"],"award-info":[{"award-number":["NSTC 113\u20102628\u2010B\u2010075\u2010003\u2010MY3"]}],"id":[{"id":"10.13039\/100007225","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100007225","name":"Ministry of Science and Technology","doi-asserted-by":"publisher","award":["NSTC 115\u20102314\u2010B\u2010075\u2010068"],"award-info":[{"award-number":["NSTC 115\u20102314\u2010B\u2010075\u2010068"]}],"id":[{"id":"10.13039\/100007225","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100011912","name":"Taipei Veterans General Hospital","doi-asserted-by":"publisher","award":["V115C\u2010029"],"award-info":[{"award-number":["V115C\u2010029"]}],"id":[{"id":"10.13039\/501100011912","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100011912","name":"Taipei Veterans General Hospital","doi-asserted-by":"publisher","award":["ACIC\u2010115\u2010004"],"award-info":[{"award-number":["ACIC\u2010115\u2010004"]}],"id":[{"id":"10.13039\/501100011912","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Cardiovasc electrophysiol"],"published-print":{"date-parts":[[2026,10]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Iatrogenic air entrainment is a preventable embolic hazard in pulsed field ablation (PFA). Mapping catheter insertion through large\u2010bore PFA sheaths may be a vulnerable step, but the roles of catheter geometry and liquid\u2010sealed insertion are unclear.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods and Results<\/jats:title>\n                    <jats:p>\n                      In an ex vivo saline tank model, ORION mini\u2010basket and SPIRAL circular mapping catheters were inserted through the FARADRIVE steerable sheath using saline infusion only, continuous manual suction, or liquid\u2010sealed insertion with a custom Adapter Sink. The primary endpoint was macroscopic air recovered distally after each trial of 10 insertions; the trial was the unit of analysis, and 0.2\u2009mL was the smallest quantitatively reportable volume. In 60 trials (600 insertions), mitigation strategy significantly affected air entrainment (Kruskal\u2013Wallis\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001). Under saline infusion alone, ORION generated more air than SPIRAL (23.86\u2009\u00b1\u20093.63 vs. 7.20\u2009\u00b1\u20092.09\u2009mL per 10 insertions; 2.39 vs. 0.72\u2009mL per insertion; adjusted\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001). Manual suction reduced entrainment to 3.96\u2009\u00b1\u20091.01 and 1.02\u2009\u00b1\u20090.45\u2009mL per 10 insertions (0.40 and 0.10\u2009mL per insertion), but residual air persisted. With liquid\u2010sealed insertion, no visually detectable or quantitatively measurable macroscopic air was observed in any trial.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Air entrainment varied according to mapping\u2010catheter geometry and mitigation strategy. Timed manual suction substantially reduced, but did not abolish, measurable air. Liquid\u2010sealed insertion was associated with no measurable macroscopic air within this ex vivo model, warranting further evaluation under physiologic pressure conditions and in clinical PFA workflows.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/jce.70492","type":"journal-article","created":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T18:25:20Z","timestamp":1788891920000},"page":"2317-2325","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Differential Air Entrainment of Mini\u2010Basket and Circular Mapping Catheters Through the FARADRIVE Sheath: Mitigation With a Liquid\u2010Sealed Insertion Method"],"prefix":"10.1111","volume":"37","author":[{"ORCID":"https:\/\/orcid.org\/0009-0006-8810-4614","authenticated-orcid":false,"given":"Thai Duy","family":"Vo","sequence":"first","affiliation":[{"name":"Division of Cardiac Electrophysiology, Cardiovascular Center Taipei Veterans General Hospital Taipei Taiwan"},{"name":"Department of Arrhythmology Cho Ray Hospital Ho Chi Minh City Vietnam"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2612-0057","authenticated-orcid":false,"given":"Ting\u2010Yung","family":"Chang","sequence":"additional","affiliation":[{"name":"Division of Cardiac Electrophysiology, Cardiovascular Center Taipei Veterans General Hospital Taipei Taiwan"},{"name":"Department of Medicine National Yang\u2010Ming Chiao\u2010Tung University Taipei Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3282-7523","authenticated-orcid":false,"given":"Chin\u2010Yu","family":"Lin","sequence":"additional","affiliation":[{"name":"Division of Cardiac Electrophysiology, Cardiovascular Center Taipei Veterans General Hospital Taipei Taiwan"},{"name":"Department of Medicine National Yang\u2010Ming Chiao\u2010Tung University Taipei Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pei\u2010Yi","family":"Wang","sequence":"additional","affiliation":[{"name":"Division of Cardiac Electrophysiology, Cardiovascular Center Taipei Veterans General Hospital Taipei Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kuo\u2010Hsiang","family":"Lu","sequence":"additional","affiliation":[{"name":"Gimer Medical Co. New Taipei City Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hsin\u2010Lei","family":"Huang","sequence":"additional","affiliation":[{"name":"National Taipei University of Nursing and Health Sciences Taipei City Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,9,8]]},"reference":[{"key":"e_1_2_11_2_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euac033"},{"key":"e_1_2_11_3_1","doi-asserted-by":"publisher","DOI":"10.1161\/circulationaha.123.063988"},{"key":"e_1_2_11_4_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa2307291"},{"key":"e_1_2_11_5_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41591-024-03114-3"},{"key":"e_1_2_11_6_1","doi-asserted-by":"publisher","DOI":"10.1161\/circulationaha.125.074485"},{"key":"e_1_2_11_7_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/eur314"},{"key":"e_1_2_11_8_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euac211"},{"key":"e_1_2_11_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcha.2025.101674"},{"key":"e_1_2_11_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/jce.70129"},{"key":"e_1_2_11_11_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euad060"},{"key":"e_1_2_11_12_1","doi-asserted-by":"publisher","DOI":"10.1002\/joa3.70021"},{"key":"e_1_2_11_13_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euag005"}],"container-title":["Journal of Cardiovascular Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jce.70492","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/jce.70492","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jce.70492","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T03:42:23Z","timestamp":1791949343000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jce.70492"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,8]]},"references-count":12,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2026,10]]}},"alternative-id":["10.1111\/jce.70492"],"URL":"https:\/\/doi.org\/10.1111\/jce.70492","archive":["Portico"],"relation":{},"ISSN":["1045-3873","1540-8167"],"issn-type":[{"value":"1045-3873","type":"print"},{"value":"1540-8167","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,8]]},"assertion":[{"value":"2026-07-09","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-08-24","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-09-08","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}