{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T17:18:56Z","timestamp":1789751936453,"version":"4.0.1"},"reference-count":19,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2018,7,13]],"date-time":"2018-07-13T00:00:00Z","timestamp":1531440000000},"content-version":"vor","delay-in-days":12,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J of Clinical Hypertension"],"published-print":{"date-parts":[[2018,7]]},"abstract":"<jats:p>\n                    The characteristics of the optimal cuff for blood pressure (\n                    <jats:styled-content style=\"fixed-case\">BP<\/jats:styled-content>\n                    ) measurement are still the subject of much debate. The choice of the appropriate cuff in obese individuals depends not only on the arm circumference but also on its shape because a conically shaped arm makes it difficult to fit the cuff to the arm. When a large\u2010size cylindrical cuff is used in conical arms, an overestimation of the true\n                    <jats:styled-content style=\"fixed-case\">BP<\/jats:styled-content>\n                    is likely to occur with\n                    <jats:styled-content style=\"fixed-case\">BP<\/jats:styled-content>\n                    discrepancies that may be as large as 10\u00a0mm\u00a0Hg. With the advent of automatic oscillometric devices, the choice of the appropriate cuff became even more controversial because with oscillometric\n                    <jats:styled-content style=\"fixed-case\">BP<\/jats:styled-content>\n                    measurement the reference point is not the artery occlusion but the oscillometric peak signal. To overcome the problem of miscuffing in obese individuals, special cuffs that can accommodate a wide range of arm sizes have been designed. Using these cuffs, accurate oscillometric\n                    <jats:styled-content style=\"fixed-case\">BP<\/jats:styled-content>\n                    measurements can be obtained over a wide range of arm circumferences using a unique software algorithm. These wide\u2010range cuffs coupled to oscillometric devices may represent a good option for\n                    <jats:styled-content style=\"fixed-case\">BP<\/jats:styled-content>\n                    measurement in very obese subjects. However, their reliability should be confirmed in larger populations and different settings.\n                  <\/jats:p>","DOI":"10.1111\/jch.13301","type":"journal-article","created":{"date-parts":[[2018,7,13]],"date-time":"2018-07-13T07:01:04Z","timestamp":1531465264000},"page":"1100-1103","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":55,"title":["Cuff challenges in blood pressure measurement"],"prefix":"10.1111","volume":"20","author":[{"given":"Paolo","family":"Palatini","sequence":"first","affiliation":[{"name":"Department of Medicine University of Padova  Padua Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roland","family":"Asmar","sequence":"additional","affiliation":[{"name":"Foundation\u2010Medical Research Institutes  Geneva Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2018,7,13]]},"reference":[{"key":"e_1_2_9_2_1","first-page":"565","article-title":"A century of confusion: which bladder for accurate blood pressure measurement? [review]","volume":"10","author":"O'Brien E","year":"1996","journal-title":"J Hum Hypertens"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1038\/ajh.2011.213"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF02367308"},{"key":"e_1_2_9_5_1","volume-title":"Blood pressure measurement: recommendations of the British Hypertension Society","author":"O'Brien E","year":"1997"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.0000154900.76284.F6"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1097\/00126097-200006000-00002"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2011.06.006"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0b013e3283435b65"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0b013e32834f98a0"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1093\/ije\/14.3.468"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1161\/HYPERTENSIONAHA.117.10237"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1038\/hr.2010.146"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0000000000000011"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0b013e32834192ef"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1038\/jhh.2008.70"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0b013e328344c73c"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0000000000001635"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0b013e3283360e98"},{"key":"e_1_2_9_20_1","unstructured":"Non\u2010invasive sphygmomanometers Part 2: Clinical investigation of automated measurement type.https:\/\/www.iso.org\/standard\/57977.html. Accessed February 6 2018."}],"container-title":["The Journal of Clinical Hypertension"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fjch.13301","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jch.13301","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,13]],"date-time":"2023-09-13T09:14:15Z","timestamp":1694596455000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jch.13301"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,7]]},"references-count":19,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2018,7]]}},"alternative-id":["10.1111\/jch.13301"],"URL":"https:\/\/doi.org\/10.1111\/jch.13301","archive":["Portico"],"relation":{},"ISSN":["1524-6175","1751-7176"],"issn-type":[{"value":"1524-6175","type":"print"},{"value":"1751-7176","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,7]]},"assertion":[{"value":"2018-04-04","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-04-04","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-07-13","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}