{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T19:32:03Z","timestamp":1791228723710,"version":"4.1.0"},"reference-count":18,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2020,1,19]],"date-time":"2020-01-19T00:00:00Z","timestamp":1579392000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"name":"Omron Healthcare Co., Ltd."}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J of Clinical Hypertension"],"published-print":{"date-parts":[[2020,2]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Wearable blood pressure (BP) monitoring devices which measure BP levels accurately both in and out of the office are valuable for hypertension management using digital technology. The authors have conducted the first comparison study of BPs measured by a recently developed wrist\u2010worn watch\u2010type oscillometric BP monitoring (WBPM) device, the \u201cHeartGuide,\u201d versus BPs measured by an ambulatory BP monitoring (ABPM) device, A&amp;D TM\u20102441, in the office (total of 4 readings alternately measured in the sitting position) and outside the office (30\u2010minutes interval measurements during daytime) in 50 consecutive patients (mean age 66.1\u00a0\u00b1\u00a010.8\u00a0years). The 2 BP monitoring devices were simultaneously worn on the same non\u2010dominant arm throughout the monitoring period. The mean difference (\u00b1SD) in systolic BPs (average of 2 readings) between WBPM and ABPM was 0.8\u00a0\u00b1\u00a012.8\u00a0mm\u00a0Hg (<jats:italic>P<\/jats:italic>\u00a0=\u00a0.564) in the office and 3.2\u00a0\u00b1\u00a017.0\u00a0mm\u00a0Hg (<jats:italic>P<\/jats:italic>\u00a0&lt;\u00a0.001) outside the office. The proportion of differences that were within \u00b110\u00a0mm\u00a0Hg was 58.7% in the office and 47.2% outside the office. In a mixed\u2010effects model analysis, the temporal trend in the difference between the out\u2010of\u2010office BPs measured by the two devices was not statistically significant. In conclusion, the difference between the WBPM and ABPM device was acceptable both in and out of the office.<\/jats:p>","DOI":"10.1111\/jch.13799","type":"journal-article","created":{"date-parts":[[2020,1,19]],"date-time":"2020-01-19T17:43:47Z","timestamp":1579455827000},"page":"135-141","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":106,"title":["The first study comparing a wearable watch\u2010type blood pressure monitor with a conventional ambulatory blood pressure monitor on in\u2010office and out\u2010of\u2010office settings"],"prefix":"10.1111","volume":"22","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8251-4480","authenticated-orcid":false,"given":"Kazuomi","family":"Kario","sequence":"first","affiliation":[{"name":"Division of Cardiovascular Medicine Department of Medicine Jichi Medical University School of Medicine Tochigi Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daichi","family":"Shimbo","sequence":"additional","affiliation":[{"name":"The Hypertension Center Columbia University Medical Center New York NY USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naoko","family":"Tomitani","sequence":"additional","affiliation":[{"name":"Division of Cardiovascular Medicine Department of Medicine Jichi Medical University School of Medicine Tochigi Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroshi","family":"Kanegae","sequence":"additional","affiliation":[{"name":"Division of Cardiovascular Medicine Department of Medicine Jichi Medical University School of Medicine Tochigi Japan"},{"name":"Genki Plaza Medical Center for Health Care Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph E.","family":"Schwartz","sequence":"additional","affiliation":[{"name":"Columbia University New York NY, USA"},{"name":"Department of Psychiatry Stony Brook University Stony Brook NY USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bryan","family":"Williams","sequence":"additional","affiliation":[{"name":"Institute of Cardiovascular Sciences University College London London UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2020,1,19]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1161\/HYP.0000000000000066"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehy339"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41440-019-0284-9"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00421-011-1983-3"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0b013e32835d124f"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0000000000000124"},{"issue":"6","key":"e_1_2_7_8_1","first-page":"713","article-title":"Continuous non\u2010invasive monitoring of blood pressure in the operating room: a cuffless optical technology at the fingertip","volume":"37","author":"Proen\u00e7a M","year":"2016","journal-title":"Physiol Meas"},{"key":"e_1_2_7_9_1","first-page":"631","article-title":"Development and validation of a novel cuff\u2010less blood pressure monitoring device","volume":"2","author":"Watanabe N","year":"2017","journal-title":"J Am Coll Cardiol Basic Trans Science"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1038\/jhh.2016.101"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1111\/jch.13499"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0000000000000357"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1111\/jch.13495"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1111\/jch.13652"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1161\/HYPERTENSIONAHA.112.198101"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1161\/HYPERTENSIONAHA.118.10971"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1712231"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1111\/jch.12500"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1161\/HYPERTENSIONAHA.118.12740"}],"container-title":["The Journal of Clinical Hypertension"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fjch.13799","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jch.13799","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/jch.13799","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jch.13799","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,7]],"date-time":"2023-09-07T00:19:58Z","timestamp":1694045998000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jch.13799"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,1,19]]},"references-count":18,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020,2]]}},"alternative-id":["10.1111\/jch.13799"],"URL":"https:\/\/doi.org\/10.1111\/jch.13799","archive":["Portico"],"relation":{},"ISSN":["1524-6175","1751-7176"],"issn-type":[{"value":"1524-6175","type":"print"},{"value":"1751-7176","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,1,19]]},"assertion":[{"value":"2019-12-19","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-12-21","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-01-19","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}