{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,14]],"date-time":"2025-05-14T01:22:12Z","timestamp":1747185732240,"version":"3.40.5"},"reference-count":18,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2020,7,9]],"date-time":"2020-07-09T00:00:00Z","timestamp":1594252800000},"content-version":"vor","delay-in-days":8,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J of Clinical Hypertension"],"published-print":{"date-parts":[[2020,7]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Automated office blood pressure measurement eliminates the white coat effect and is associated with awake ambulatory blood pressure. This study examined whether automated office blood pressure values at lower limits were comparable to those of awake and mean 24\u2010hour ambulatory blood pressure. A total of 552 patients were included in the study, involving 293 (53.1%) men and 259 (46.9%) women, with a mean age 55.0\u00a0\u00b1\u00a012.5, of whom 36% were treated for hypertension. Both systolic and diastolic automated office blood pressures exhibited lower values compared to awake ambulatory blood pressure among 254 individuals with systolic automated office blood pressure &lt;130\u00a0mm\u00a0Hg (119\u00a0\u00b1\u00a08\u00a0mm\u00a0Hg vs 125\u00a0\u00b1\u00a011\u00a0mm\u00a0Hg, <jats:italic>P<\/jats:italic>\u00a0&lt;\u00a0.0001 and 75\u00a0\u00b1\u00a09\u00a0mm\u00a0Hg vs 79\u00a0\u00b1\u00a09\u00a0mm Hg, <jats:italic>P<\/jats:italic>\u00a0&lt;\u00a0.0001 for systolic and diastolic BPs, respectively). Furthermore, the comparison of systolic automated office blood pressure to the mean 24\u2010hour ambulatory blood pressure levels also showed lower values (119\u00a0\u00b1\u00a08 vs 121\u00a0\u00b1\u00a010, <jats:italic>P<\/jats:italic>\u00a0=\u00a0.007), whereas the diastolic automated office blood pressure measurements were similar to 24\u2010hour ambulatory blood pressure values. Our findings show that when automated office blood pressure readings express values &lt;130\/80\u00a0mm\u00a0Hg in repeated office visits, further investigation should be performed only when masked hypertension is suspected; otherwise, higher automated office blood pressure values could be used for the diagnosis of uncontrolled hypertension, especially in individuals with organ damage.<\/jats:p>","DOI":"10.1111\/jch.13927","type":"journal-article","created":{"date-parts":[[2020,7,9]],"date-time":"2020-07-09T13:16:30Z","timestamp":1594300590000},"page":"1177-1183","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Automated office blood pressure is in agreement with awake and mean 24\u2010hour ambulatory blood pressure at the lower blood pressure range"],"prefix":"10.1111","volume":"22","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5436-2889","authenticated-orcid":false,"given":"Emmanuel A.","family":"Andreadis","sequence":"first","affiliation":[{"name":"Hypertension and Cardiovascular Disease Prevention Center Athens Medical Group Psychiko Clinic Neo Psychiko Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Charalampia V.","family":"Geladari","sequence":"additional","affiliation":[{"name":"Hypertension and Cardiovascular Disease Prevention Center Athens Medical Group Psychiko Clinic Neo Psychiko Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Epameinondas T.","family":"Angelopoulos","sequence":"additional","affiliation":[{"name":"Hypertension and Cardiovascular Disease Prevention Center Athens Medical Group Psychiko Clinic Neo Psychiko Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2020,7,9]]},"reference":[{"issue":"6","key":"e_1_2_7_2_1","article-title":"2017 ACC\/AHA\/AAPA\/ABC\/ACPM\/AGS\/APhA\/ASH\/ASPC\/NMA\/PCNA Guideline for the Prevention, Detection, Evaluation, and Management of High Blood Pressure in Adults: A Report of the American College of Cardiology\/American Heart Association Task Force on Clinical Practice Guidelines","volume":"71","author":"Whelton PK","year":"2018","journal-title":"Hypertension"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0000000000001940"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0b013e3283577b05"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/jch.13090"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1111\/jch.13319"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1111\/jch.13748"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0b013e328335d091"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.d286"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1751-7176.2009.00199.x"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0b013e3280b083ce"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1511939"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1001286"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(13)60852-1"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1111\/jch.13409"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1161\/HYPERTENSIONAHA.116.08076"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1161\/HYPERTENSIONAHA.116.08216"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1161\/HYP.0000000000000087"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cjca.2016.02.066"}],"container-title":["The Journal of Clinical Hypertension"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fjch.13927","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jch.13927","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/jch.13927","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jch.13927","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,5]],"date-time":"2023-09-05T21:01:46Z","timestamp":1693947706000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jch.13927"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7]]},"references-count":18,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2020,7]]}},"alternative-id":["10.1111\/jch.13927"],"URL":"https:\/\/doi.org\/10.1111\/jch.13927","archive":["Portico"],"relation":{},"ISSN":["1524-6175","1751-7176"],"issn-type":[{"type":"print","value":"1524-6175"},{"type":"electronic","value":"1751-7176"}],"subject":[],"published":{"date-parts":[[2020,7]]},"assertion":[{"value":"2020-04-11","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-05-27","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-07-09","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}