{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T17:18:54Z","timestamp":1789751934100,"version":"4.0.1"},"reference-count":25,"publisher":"Wiley","issue":"12","license":[{"start":{"date-parts":[[2020,10,5]],"date-time":"2020-10-05T00:00:00Z","timestamp":1601856000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/100013888","name":"Heart and Stroke Foundation of British Columbia and Yukon","doi-asserted-by":"publisher","award":["RE\/18\/6\/34217"],"award-info":[{"award-number":["RE\/18\/6\/34217"]}],"id":[{"id":"10.13039\/100013888","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J of Clinical Hypertension"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Hypertension guidelines recommend that blood pressure (BP) should be measured using a monitor that has passed validation testing for accuracy. BP monitors that have not undergone rigorous validation testing can still be cleared by regulatory authorities for marketing and sale. This is the situation for most BP monitors worldwide. Thus, consumers (patients, health professionals, procurement officers, and general public) may unwittingly purchase BP monitors that are non\u2010validated and more likely to be inaccurate. Without prior knowledge of these issues, it is extremely difficult for consumers to distinguish validated from non\u2010validated BP monitors. For the above reasons, the aim of this paper is to provide consumers guidance on how to check\n                    <jats:bold>whether<\/jats:bold>\n                    a BP monitor has been properly validated for accuracy. The process involves making an online search of listings of BP monitors that have been assessed for validation status. Only those monitors that have been properly validated are recommended for BP measurement. There are numerous different online listings of BP monitors, several are country\u2010specific and two are general (international) listings. Because monitors can be marketed using alternative model names in different countries, if a monitor is not found on one listing, it may be worthwhile cross\u2010checking with a different listing. This information is widely relevant to anyone seeking to purchase a home, clinic, or ambulatory BP monitor, including individual consumers for use personally or policy makers and those procuring monitors for use in healthcare systems, and retailers looking to stock only validated BP monitors.\n                  <\/jats:p>","DOI":"10.1111\/jch.14065","type":"journal-article","created":{"date-parts":[[2020,10,5]],"date-time":"2020-10-05T13:52:01Z","timestamp":1601905921000},"page":"2167-2174","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":49,"title":["How to check whether a blood pressure monitor has been properly validated for accuracy"],"prefix":"10.1111","volume":"22","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4760-1634","authenticated-orcid":false,"given":"Dean S.","family":"Picone","sequence":"first","affiliation":[{"name":"Menzies Institute for Medical Research University of Tasmania Hobart Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3541-2817","authenticated-orcid":false,"given":"Raj","family":"Padwal","sequence":"additional","affiliation":[{"name":"Department of Medicine University of Alberta Edmonton AB Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1093-4742","authenticated-orcid":false,"given":"Norm R. C.","family":"Campbell","sequence":"additional","affiliation":[{"name":"Department of Medicine, Physiology and Pharmacology and Community Health Sciences O\u2019Brien Institute for Public Health and Libin Cardiovascular Institute of Alberta University of Calgary Calgary AB Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pierre","family":"Boutouyrie","sequence":"additional","affiliation":[{"name":"Department of Pharmacology European Georges Pompidou Hospital Assistance Publique H\u00f4pitaux de Paris Inserm UMR 970 Universit\u00e9 de Paris Paris France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1315-6747","authenticated-orcid":false,"given":"Tammy M.","family":"Brady","sequence":"additional","affiliation":[{"name":"Division of Pediatric Nephrology Johns Hopkins University School of Medicine Baltimore MD USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael Hecht","family":"Olsen","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine Holbaek Hospital Holbaek Denmark"},{"name":"Centre for Individualized Medicine in Arterial Diseases Department of Regional Health Research University of Southern Denmark Odense Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Delles","sequence":"additional","affiliation":[{"name":"Institute of Cardiovascular and Medical Sciences University of Glasgow Glasgow UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cintia","family":"Lombardi","sequence":"additional","affiliation":[{"name":"Department of Non\u2010Communicable Diseases and Mental Health Pan American Health Organization Washington DC USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1927-8139","authenticated-orcid":false,"given":"Azra","family":"Mahmud","sequence":"additional","affiliation":[{"name":"King Abdul Aziz Cardiac Center King Abdul Aziz Medical City Riyadh Saudi Arabia"},{"name":"National Guard Health Affairs Riyadh Saudi Arabia"},{"name":"King Abdullah International Medical Research Center &amp; King Saud bin Abdulaziz University for Health Sciences Riyadh Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yaxing","family":"Meng","sequence":"additional","affiliation":[{"name":"Menzies Institute for Medical Research University of Tasmania Hobart Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gontse G.","family":"Mokwatsi","sequence":"additional","affiliation":[{"name":"Hypertension in Africa Research Team (HART) North\u2010West University Potchefstroom South Africa"},{"name":"Medical Research Council Unit for Hypertension and Cardiovascular Disease North\u2010West University Potchefstroom South Africa"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9871-6845","authenticated-orcid":false,"given":"Pedro","family":"Ordunez","sequence":"additional","affiliation":[{"name":"Department of Non\u2010Communicable Diseases and Mental Health Pan American Health Organization Washington DC USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hoang T.","family":"Phan","sequence":"additional","affiliation":[{"name":"Menzies Institute for Medical Research University of Tasmania Hobart Australia"},{"name":"Pham Ngoc Thach University of Medicine Ho Chi Minh City Vietnam"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giacomo","family":"Pucci","sequence":"additional","affiliation":[{"name":"Unit of Internal Medicine at Terni University Hospital Department of Medicine University of Perugia Perugia Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aletta E.","family":"Schutte","sequence":"additional","affiliation":[{"name":"Hypertension in Africa Research Team (HART) North\u2010West University Potchefstroom South Africa"},{"name":"Medical Research Council Unit for Hypertension and Cardiovascular Disease North\u2010West University Potchefstroom South Africa"},{"name":"School of Public Health and Community Medicine University of New South Wales The George Institute for Global Health Sydney Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ki\u2010Chul","family":"Sung","sequence":"additional","affiliation":[{"name":"Division of Cardiology Department of Internal Medicine Kangbuk Samsung Hospital Sungkyunkwan University School of Medicine Seoul Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xin\u2010Hua","family":"Zhang","sequence":"additional","affiliation":[{"name":"World Hypertension League Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James E.","family":"Sharman","sequence":"additional","affiliation":[{"name":"Menzies Institute for Medical Research University of Tasmania Hobart Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"name":"for the Accuracy in Measurement of Blood Pressure (AIM\u2010BP) Collaborative","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2020,10,5]]},"reference":[{"issue":"10159","key":"e_1_2_8_2_1","doi-asserted-by":"crossref","first-page":"1923","DOI":"10.1016\/S0140-6736(18)32225-6","article-title":"Global, regional, and national comparative risk assessment of 84 behavioural, environmental and occupational, and metabolic risks or clusters of risks for 195 countries and territories, 1990\u20132017: a systematic analysis for the Global Burden of Disease Study 2017","volume":"392","author":"GBD Risk Factor Collaborators","year":"2018","journal-title":"Lancet"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(15)01225-8"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.HYP.0000150859.47929.8e"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0000000000001940"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2017.11.006"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1161\/HYPERTENSIONAHA.120.15026"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0000000000000673"},{"issue":"3","key":"e_1_2_8_9_1","first-page":"7","article-title":"7th Brazilian Guideline of Arterial Hypertension: Chapter 2 \u2010 Diagnosis and Classification","volume":"107","author":"Malachias MVB","year":"2016","journal-title":"Arq Bras Cardiol"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41440-019-0284-9"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cjca.2018.02.022"},{"key":"e_1_2_8_12_1","unstructured":"Medaval Ltd.Blood Pressure Monitors.2020;https:\/\/medaval.ie\/device\u2010category\/blood\u2010pressure\u2010monitors\/. Accessed 14 January 2020"},{"key":"e_1_2_8_13_1","unstructured":"STRIDE BP.Only 6% of blood pressure device on the market approved by the STRIDE BP. 2020;https:\/\/www.stridebp.org\/. Accessed 22 May 2020."},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1161\/HYPERTENSIONAHA.120.14719"},{"issue":"1","key":"e_1_2_8_15_1","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1097\/MBP.0b013e3283262f31","article-title":"Home sphygmomanometers: validation versus accuracy","volume":"14","author":"Akpolat T","year":"2009","journal-title":"Blood Press Monit"},{"issue":"4","key":"e_1_2_8_16_1","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1097\/MBP.0000000000000121","article-title":"Reliability of home blood pressure monitoring: in the context of validation and accuracy","volume":"20","author":"Jung MH","year":"2015","journal-title":"Blood Press Monit"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1111\/jch.14058"},{"issue":"3","key":"e_1_2_8_18_1","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1097\/HJH.0b013e3282f2fdd4","article-title":"Attitudes of primary care physicians and their patients about home blood pressure monitoring in Ontario","volume":"26","author":"Logan AG","year":"2008","journal-title":"J Hypertens"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1111\/jch.13735"},{"key":"e_1_2_8_20_1","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0000000000002246"},{"key":"e_1_2_8_21_1","unstructured":"World Health Organization.WHO technical specifications for automated non\u2010invasive blood pressure measuring devices with cuff. Geneva Switzerland. World Health Organization;2020;https:\/\/www.who.int\/docs\/default\u2010source\/searo\/indonesia\/who\u2010tech\u2010spec\u2010for\u2010automated\u2010non\u2010invasive\u2010blood\u2010pressure\u2010measuring\u2010devices\u2010with\u2010cuff.pdf?sfvrsn=b112be47_2"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1161\/HYPERTENSIONAHA.118.11990"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0000000000002289"},{"key":"e_1_2_8_24_1","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0000000000001197"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0000000000002112"},{"key":"e_1_2_8_26_1","doi-asserted-by":"crossref","DOI":"10.1111\/jch.14017","article-title":"Brief online certification course for measuring blood pressure with an automated blood pressure device. A free new resource to support World Hypertension Day Oct 17, 2020","author":"Campbell NRC","year":"2020","journal-title":"J Clin Hypertens (Greenwich)"}],"container-title":["The Journal of Clinical Hypertension"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jch.14065","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/jch.14065","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jch.14065","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,3]],"date-time":"2023-09-03T14:23:35Z","timestamp":1693751015000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jch.14065"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,10,5]]},"references-count":25,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["10.1111\/jch.14065"],"URL":"https:\/\/doi.org\/10.1111\/jch.14065","archive":["Portico"],"relation":{},"ISSN":["1524-6175","1751-7176"],"issn-type":[{"value":"1524-6175","type":"print"},{"value":"1751-7176","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,10,5]]},"assertion":[{"value":"2020-07-26","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-09-09","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-10-05","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}