{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T20:31:03Z","timestamp":1789158663794,"version":"build-2803163510"},"reference-count":8,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2024,1,8]],"date-time":"2024-01-08T00:00:00Z","timestamp":1704672000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J of Clinical Hypertension"],"published-print":{"date-parts":[[2024,2]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Hypertension guidelines recommend team\u2010based care for the treatment of high blood pressure (BP). Clinical pharmacists can help patients get to goal BP with rapid medication titration in conjunction with telehealth visits. We conducted a pharmacist\u2010led home BP monitoring pilot program from June 2020 to September 2021. Forty\u2010two patients with a SBP \u2265140 despite using \u22642 antihypertensive medications were referred for pharmacist telehealth with expedited medication titration to achieve a BP goal &lt;130\/80. The mean enrollment SBP\/DBP was 155.2 (SD, 15.8)\/89.7 (SD, 11.5) mm Hg, and the mean completion SBP\/DBP was 132.1 (SD, 10.9)\/77.6 (SD, 10). The number of hypertension medications prescribed increased from 1.3 to 1.6 with no instances of falls or hypotension. At completion, 31% of patients had an automated office blood pressure (AOBP) with SBP &lt;130\u00a0mm Hg and DBP &lt;80\u00a0mm Hg. A pharmacist\u2010led, home BP monitoring telehealth pilot program helped patients safely achieve BP goals.<\/jats:p>","DOI":"10.1111\/jch.14750","type":"journal-article","created":{"date-parts":[[2024,1,9]],"date-time":"2024-01-09T07:04:17Z","timestamp":1704783857000},"page":"217-220","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Pharmacist\u2010led rapid medication titration for hypertension management by telehealth: A quality improvement initiative"],"prefix":"10.1111","volume":"26","author":[{"given":"Anthony M.","family":"Ishak","sequence":"first","affiliation":[{"name":"Beth Israel Deaconess Medical Center  Boston Massachusetts USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenneth J.","family":"Mukamal","sequence":"additional","affiliation":[{"name":"Department of Medicine Beth Israel Deaconess Medical Center Harvard Medical School  Boston Massachusetts USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julia M.","family":"Wood","sequence":"additional","affiliation":[{"name":"Simmons College  Boston Massachusetts USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Medha","family":"Vyavahare","sequence":"additional","affiliation":[{"name":"Department of Medicine Brigham and Women's Hospital Harvard Medical School  Boston Massachusetts USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5744-1099","authenticated-orcid":false,"given":"Jennifer L.","family":"Cluett","sequence":"additional","affiliation":[{"name":"Department of Medicine Beth Israel Deaconess Medical Center Harvard Medical School  Boston Massachusetts USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4168-2696","authenticated-orcid":false,"given":"Stephen P.","family":"Juraschek","sequence":"additional","affiliation":[{"name":"Department of Medicine Beth Israel Deaconess Medical Center Harvard Medical School  Boston Massachusetts USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2024,1,8]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2020.14545"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1177\/1715163519839675"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2013.6549"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1161\/HYP.0000000000000065"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0000000000002843"},{"issue":"14","key":"e_1_2_8_7_1","first-page":"e42","article-title":"Self\u2010measured blood pressure monitoring at home: a joint policy statement from the American Heart Association and American Medical Association","volume":"142","author":"Shimbo D","year":"2020","journal-title":"Circulation"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1161\/HYP.0000000000000087"},{"key":"e_1_2_8_9_1","unstructured":"American Medical Association.Self\u2010measured blood pressure device accuracy test. Accessed October 27 2022.https:\/\/targetbp.org\/tools_downloads\/device\u2010accuracy\u2010test\/"}],"container-title":["The Journal of Clinical Hypertension"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jch.14750","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,7]],"date-time":"2024-03-07T12:10:20Z","timestamp":1709813420000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jch.14750"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,8]]},"references-count":8,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024,2]]}},"alternative-id":["10.1111\/jch.14750"],"URL":"https:\/\/doi.org\/10.1111\/jch.14750","archive":["Portico"],"relation":{},"ISSN":["1524-6175","1751-7176"],"issn-type":[{"value":"1524-6175","type":"print"},{"value":"1751-7176","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,8]]},"assertion":[{"value":"2023-09-20","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-10-26","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-01-08","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}