{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,24]],"date-time":"2026-03-24T00:14:03Z","timestamp":1774311243057,"version":"3.50.1"},"reference-count":27,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2026,2,23]],"date-time":"2026-02-23T00:00:00Z","timestamp":1771804800000},"content-version":"vor","delay-in-days":22,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"},{"start":{"date-parts":[[2026,2,1]],"date-time":"2026-02-01T00:00:00Z","timestamp":1769904000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["82270536"],"award-info":[{"award-number":["82270536"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J of Clinical Hypertension"],"published-print":{"date-parts":[[2026,2]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:p>\n                    This study evaluated the accuracy of a variety of home upper\u2010arm oscillometric blood pressure monitors (BPMs) from 448 participants against the FDA\u2010certified XYZ110 auscultatory device using simultaneous measurements. Descriptive statistics were used to summarize the key findings of the study. Device performance was evaluated referencing international standards (ISO 81060\u20132:2013), where a mean absolute difference of \u22645 mmHg was defined as \u201cAccurate.\u201d In addition, survey questionnaires completed by a subset of participants were analyzed to provide supplementary insights. A total of 448 consecutive outpatient clinical patients attending a routine clinical visit with their BPMs (male 215 and female 233) were eligible to participate in this study. The overall mean age of the participants was 62.35\u00b112.59 years. Most of the BPMs included in this study were of the Omron brand (79.69%,\n                    <jats:italic>n<\/jats:italic>\n                    = 357), followed by Yuwell (5.8%,\n                    <jats:italic>n<\/jats:italic>\n                    = 26) and others. 76.32% of systolic blood pressure (SBP) measurements and 69.89% of diastolic blood pressure (DBP) measurements from BPMs exhibited differences of \u22645 mmHg compared to the reference calibrator. 70.89% (\n                    <jats:italic>n<\/jats:italic>\n                    = 318) were accurate in measuring SBP, and 60.27% (\n                    <jats:italic>n<\/jats:italic>\n                    = 270) were accurate in measuring DBP. Our study revealed that over 20% of BPMs exhibited discrepancies of more than 5 mmHg compared to a reference calibrator. Overall, the Omron U30, HEM\u20107211, and U10 models demonstrated relatively higher accuracy in blood pressure measurements. Regular patient to patient validation of BPMs is crucial to ensure accurate measurements for daily use.\n                  <\/jats:p>","DOI":"10.1111\/jch.70222","type":"journal-article","created":{"date-parts":[[2026,3,8]],"date-time":"2026-03-08T10:49:42Z","timestamp":1772966982000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["The Post\u2010Marketing Real\u2010World Outpatient Clinical Validation of Electronic Blood Pressure Monitors"],"prefix":"10.1111","volume":"28","author":[{"given":"Zhiping","family":"Zhang","sequence":"first","affiliation":[{"name":"Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine  Shanghai People's Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Muge","family":"Fan","sequence":"additional","affiliation":[{"name":"General Medicine Department of Fangsong Community Health Service Center of Songjiang District  Shanghai People's Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qingsong","family":"Zhao","sequence":"additional","affiliation":[{"name":"Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine  Shanghai People's Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiaqi","family":"Liu","sequence":"additional","affiliation":[{"name":"Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine  Shanghai People's Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lingyun","family":"Su","sequence":"additional","affiliation":[{"name":"General Medicine Department of Zhoujiadu Community Health Service Center of Pudong District  Shanghai People's Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jinliang","family":"Wang","sequence":"additional","affiliation":[{"name":"School of Health Science and Engineering University of Shanghai for Science and Technology  Shanghai People's Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peiyao","family":"Xiao","sequence":"additional","affiliation":[{"name":"School of Health Science and Engineering University of Shanghai for Science and Technology  Shanghai People's Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ziyang","family":"Fang","sequence":"additional","affiliation":[{"name":"School of Health Science and Engineering University of Shanghai for Science and Technology  Shanghai People's Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yikai","family":"Li","sequence":"additional","affiliation":[{"name":"School of Health Science and Engineering University of Shanghai for Science and Technology  Shanghai People's Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yanbin","family":"Yue","sequence":"additional","affiliation":[{"name":"Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine  Shanghai People's Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rong","family":"Jiang","sequence":"additional","affiliation":[{"name":"Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine  Shanghai People's Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Wang","sequence":"additional","affiliation":[{"name":"General Medicine Department of Fangsong Community Health Service Center of Songjiang District  Shanghai People's Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhi","family":"Zhang","sequence":"additional","affiliation":[{"name":"Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine  Shanghai People's Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2026,2,23]]},"reference":[{"key":"e_1_2_12_2_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41440\u2010018\u20100030\u20108"},{"key":"e_1_2_12_3_1","doi-asserted-by":"publisher","DOI":"10.1109\/tbme.2022.3201433"},{"key":"e_1_2_12_4_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41371\u2010022\u201000693\u2010x"},{"key":"e_1_2_12_5_1","doi-asserted-by":"publisher","DOI":"10.3389\/fphys.2019.01415"},{"key":"e_1_2_12_6_1","doi-asserted-by":"publisher","DOI":"10.1097\/mbp.0000000000000356"},{"key":"e_1_2_12_7_1","doi-asserted-by":"publisher","DOI":"10.1111\/jch.13902"},{"key":"e_1_2_12_8_1","doi-asserted-by":"publisher","DOI":"10.1093\/ajh\/hpw034"},{"key":"e_1_2_12_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jash.2015.04.007"},{"key":"e_1_2_12_10_1","doi-asserted-by":"publisher","DOI":"10.1093\/ajh\/hpx056"},{"key":"e_1_2_12_11_1","doi-asserted-by":"publisher","DOI":"10.1097\/hjh.0000000000002921"},{"key":"e_1_2_12_12_1","doi-asserted-by":"publisher","DOI":"10.1097\/mbp.0000000000000485"},{"key":"e_1_2_12_13_1","doi-asserted-by":"publisher","DOI":"10.1097\/hjh.0000000000003480"},{"key":"e_1_2_12_14_1","doi-asserted-by":"publisher","DOI":"10.3399\/bjgp20x710381"},{"key":"e_1_2_12_15_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41440\u2010023\u201001311\u20100"},{"key":"e_1_2_12_16_1","doi-asserted-by":"publisher","DOI":"10.1093\/ajh\/hpx041"},{"key":"e_1_2_12_17_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0155677"},{"key":"e_1_2_12_18_1","doi-asserted-by":"publisher","DOI":"10.1111\/jch.13460"},{"key":"e_1_2_12_19_1","doi-asserted-by":"publisher","DOI":"10.1097\/mbp.0000000000000268"},{"key":"e_1_2_12_20_1","volume-title":"ISO 81060\u20131:2012. Non\u2010invasive Sphygmomanometers \u2013 Part 1: Requirements and Test Methods for Non\u2010Automated Measurement Type","author":"Standardization IOf","year":"2012"},{"key":"e_1_2_12_21_1","volume-title":"ANSI\/AAMI\/ISO 81060\u20132:2013. Non\u2010invasive Sphygmomanometers \u2013 Part 2: Clinical Validation of Automated Measurement Type","author":"Association for the Advancement of Medical Instrumentation","year":"2013"},{"key":"e_1_2_12_22_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12875\u2010022\u201001962\u2010x"},{"key":"e_1_2_12_23_1","doi-asserted-by":"publisher","DOI":"10.1097\/hjh.0000000000002289"},{"key":"e_1_2_12_24_1","doi-asserted-by":"publisher","DOI":"10.3109\/03091909209030219"},{"key":"e_1_2_12_25_1","doi-asserted-by":"publisher","DOI":"10.1097\/hjh.0000000000002460"},{"key":"e_1_2_12_26_1","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0b013e328330d47b"},{"key":"e_1_2_12_27_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41371\u2010022\u201000747\u20100"},{"key":"e_1_2_12_28_1","doi-asserted-by":"publisher","DOI":"10.1111\/jch.14065"}],"container-title":["The Journal of Clinical Hypertension"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jch.70222","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/jch.70222","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jch.70222","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,23]],"date-time":"2026-03-23T23:31:37Z","timestamp":1774308697000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jch.70222"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2]]},"references-count":27,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026,2]]}},"alternative-id":["10.1111\/jch.70222"],"URL":"https:\/\/doi.org\/10.1111\/jch.70222","archive":["Portico"],"relation":{},"ISSN":["1524-6175","1751-7176"],"issn-type":[{"value":"1524-6175","type":"print"},{"value":"1751-7176","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2]]},"assertion":[{"value":"2025-11-10","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-02-05","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-02-23","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70222"}}