{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T16:33:01Z","timestamp":1789144381852,"version":"build-2803163510"},"reference-count":16,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2018,10,31]],"date-time":"2018-10-31T00:00:00Z","timestamp":1540944000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"name":"Foundation of the American Association of Orthodontists","award":["Orthodontic Faculty Development Fellowship Award"],"award-info":[{"award-number":["Orthodontic Faculty Development Fellowship Award"]}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Esthet Restor Dent"],"published-print":{"date-parts":[[2019,1]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Objective<\/jats:title><jats:p>The aims of this study were (1) to investigate how relevant intraoral photographs are to contemporary orthodontic diagnosis and (2) to assess orthodontists' ability to accurately diagnose angle classification and dental midlines using standardized intraoral photographs.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Study participants were orthodontists who completed a survey regarding photography protocols and their use of intraoral photographs for diagnosis. Each participant was randomized to complete 1 visual diagnostic task regarding either angle classification or midlines. Accuracy was compared across groups and camera angulations.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>In all, 80% of 192 respondents reported using photographs and clinic notes to plan orthodontic treatment; 50% also included dental casts. For the angle task, accuracy judging molar and canine classification was 79.9% and 51.3%, respectively with ideal standardized photographs. As camera angulation deviated, accuracy decreased significantly (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.0001). For the midline task, accuracy judging the direction of deviation decreased with a small camera angulation change yet increased with a large change (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.001).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>When using ideal intraoral photographs alone to diagnose angle classification and midline relationships, accuracy is not likely to be greater than 80%. As camera angulation becomes less ideal, by 15 degrees when judging angle classification or 4 degrees when judging midlines, accuracy is likely to significantly decrease.<\/jats:p><\/jats:sec><jats:sec><jats:title>Clinical significance<\/jats:title><jats:p>For the clinician who wants to have the most accurate and complete records, our results suggest that intra\u2010oral photos alone may not be adequate when it comes to judging occlusal relationships such as angle classification and esthetic parameters like midlines. When using ideal intraoral photographs to diagnose angle classification and midline relationships, accuracy is not likely to be greater than 80%. As camera angulation becomes less ideal, by as little as 15 degrees when judging angle classification or 4 degrees when judging midlines, accuracy is likely to decrease significantly. Understanding these limitations will allow clinicians to improve both their clinical photography technique and their diagnostic skills.<\/jats:p><\/jats:sec>","DOI":"10.1111\/jerd.12426","type":"journal-article","created":{"date-parts":[[2018,11,1]],"date-time":"2018-11-01T02:39:55Z","timestamp":1541039995000},"page":"64-71","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":34,"title":["Diagnostic accuracy of intraoral photographic orthodontic records"],"prefix":"10.1111","volume":"31","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5010-9253","authenticated-orcid":false,"given":"Tate H.","family":"Jackson","sequence":"first","affiliation":[{"name":"Department of Orthodontics UNC School of Dentistry  Chapel Hill North Carolina"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher J.","family":"Kirk","sequence":"additional","affiliation":[{"name":"Private Practice of Orthodontics  Ontario Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ceib","family":"Phillips","sequence":"additional","affiliation":[{"name":"Department of Orthodontics UNC School of Dentistry  Chapel Hill North Carolina"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lorne D.","family":"Koroluk","sequence":"additional","affiliation":[{"name":"Department of Orthodontics UNC School of Dentistry  Chapel Hill North Carolina"},{"name":"Department of Pediatric Dentistry UNC School of Dentistry  Chapel Hill North Carolina"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2018,10,31]]},"reference":[{"issue":"3","key":"e_1_2_8_2_1","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1080\/19424396.2009.12222960","article-title":"History and current use of clinical photography in orthodontics","volume":"37","author":"Galante DL","year":"2009","journal-title":"J Calif Dent Assoc."},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cden.2011.02.001"},{"key":"e_1_2_8_4_1","unstructured":"Clinical practice guidelines for orthodontics and dentofacial orthopedics[Internet]: American Association of Orthodontists;2014. Available from:https:\/\/www.aaoinfo.org\/system\/files\/media\/documents\/2014%20Cllinical%20Practice%20Guidelines.pdf."},{"key":"e_1_2_8_5_1","unstructured":"American Board of Orthodontics: Ideal Photographs and Radiographs [Internet];2016. Available from:https:\/\/www.americanboardortho.com\/media\/1206\/example-photos-radiographs.pdf."},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajodo.2007.04.038"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1038\/sj.bdj.2014.141"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.pio.2011.12.002"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1093\/ejo\/cjv077"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajodo.2007.12.023"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1089\/tmj.2016.0128"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1093\/ortho\/29.2.125"},{"key":"e_1_2_8_13_1","unstructured":"American Assoication of Orthodontists Partners in Research Program [Internet]: American Association of Orthodontists;2016. Available from:http:\/\/s-7d1b1f-i.sgizmo.com\/s3\/i-101302209-1050947\/?sguid=101302209."},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1179\/146531205225020880"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.2307\/2529310"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1093\/ejo\/cjw033"},{"issue":"4","key":"e_1_2_8_17_1","first-page":"343","article-title":"Impact of digital intraoral scan strategies on the impression accuracy using the TRIOS pod scanner","volume":"47","author":"Muller P","year":"2016","journal-title":"Quintessence Int"}],"container-title":["Journal of Esthetic and Restorative Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fjerd.12426","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jerd.12426","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,14]],"date-time":"2023-09-14T18:14:48Z","timestamp":1694715288000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jerd.12426"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,10,31]]},"references-count":16,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,1]]}},"alternative-id":["10.1111\/jerd.12426"],"URL":"https:\/\/doi.org\/10.1111\/jerd.12426","archive":["Portico"],"relation":{},"ISSN":["1496-4155","1708-8240"],"issn-type":[{"value":"1496-4155","type":"print"},{"value":"1708-8240","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,10,31]]},"assertion":[{"value":"2018-07-31","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-09-05","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-10-31","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}