{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T18:38:05Z","timestamp":1791916685302,"version":"4.3.4"},"reference-count":93,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2023,4,6]],"date-time":"2023-04-06T00:00:00Z","timestamp":1680739200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Esthet Restor Dent"],"published-print":{"date-parts":[[2023,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>Within the development of digital technologies, dental professionals aim to integrate virtual diagnostic articulated casts obtained by using intraoral scanners (IOSs), the mandibular motion of the patient recorded by using an optical jaw tracking system, and the information provided by computerized occlusal analysis systems. This article describes the various digital technologies available for obtaining the digital occlusion of a patient and outlines its challenges and limitations.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Overview<\/jats:title>\n                    <jats:p>The factors that influence the accuracy of the maxillomandibular relationship of diagnostic casts obtained by using IOSs are reviewed, as well as the occurrence of occlusal collisions or mesh interpenetrations. Different jaw tracking systems with varying digital technologies including ultrasonic systems, photometric devices, and artificial intelligence algorithms are reviewed. Computerized occlusal analysis systems for detecting occlusal contacts in a time sequential manner with the pressure distribution on the occlusal surfaces are reviewed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Digital technologies provide powerful diagnostic and design tools for prosthodontic care. However, the accuracy of these digital technologies for acquiring and analyzing the static and dynamic occlusion need to be further analyzed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical Significance<\/jats:title>\n                    <jats:p>Efficiently implementing digital technologies into dental practice requires an understanding of the limitations and state of current development of the digital acquisition methods for digitizing the static and dynamic occlusion of a patient by using IOSs, digital jaw trackers, and computerized occlusal analysis devices.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/jerd.13044","type":"journal-article","created":{"date-parts":[[2023,4,6]],"date-time":"2023-04-06T07:09:50Z","timestamp":1680764990000},"page":"735-744","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":114,"title":["An overview of the digital occlusion technologies: Intraoral scanners, jaw tracking systems, and computerized occlusal analysis devices"],"prefix":"10.1111","volume":"35","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2854-1135","authenticated-orcid":false,"given":"Marta","family":"Revilla\u2010Le\u00f3n","sequence":"first","affiliation":[{"name":"Department of Restorative Dentistry, School of Dentistry University of Washington  Seattle Washington USA"},{"name":"Research and Digital Dentistry, Kois Center  Seattle Washington USA"},{"name":"Department of Prosthodontics School of Dental Medicine, Tufts University  Boston Massachusetts USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dean E.","family":"Kois","sequence":"additional","affiliation":[{"name":"Kois Center  Seattle Washington USA"},{"name":"Private Practice  Seattle Washington USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan M.","family":"Zeitler","sequence":"additional","affiliation":[{"name":"IT, Kois Center  Seattle Washington USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wael","family":"Att","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics School of Dental Medicine, Tuff University  Boston Massachusetts USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John C.","family":"Kois","sequence":"additional","affiliation":[{"name":"Kois Center  Seattle Washington USA"},{"name":"Private Practice  Seattle Washington USA"},{"name":"Department of Restorative Dentistry School of Dental Medicine, University of Washington  Seattle Washington USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2023,4,6]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2016.12.001"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM188907041210103"},{"key":"e_1_2_9_4_1","first-page":"573","article-title":"Movements of the mandibular condyles and dental articulation","volume":"38","author":"Walker WE","year":"1896","journal-title":"Dent Cosmos"},{"key":"e_1_2_9_5_1","first-page":"61","article-title":"Studies in the masticatory movements of the human lower jaw","volume":"61","author":"Hildebrand GY","year":"1931","journal-title":"Arch Physiol"},{"key":"e_1_2_9_6_1","first-page":"1642","article-title":"An analysis of the work and ideas of investigators and authors of relations and movements of the mandible","volume":"16","author":"Hall RE","year":"1922","journal-title":"J Am Dent Assoc"},{"key":"e_1_2_9_7_1","first-page":"19","article-title":"Studies in the mobility of the human mandible","volume":"10","author":"Posselt U","year":"1952","journal-title":"Acta Odontol Scand"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(59)90153-2"},{"key":"e_1_2_9_9_1","first-page":"99","article-title":"A new method of recording gnathological movements","volume":"45","author":"Swanson KH","year":"1966","journal-title":"Northwest Dent"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(69)90248-0"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(71)90085-0"},{"key":"e_1_2_9_12_1","volume-title":"The Case Gnathic Replicator for the Investigation of Mandibular Movements","author":"Gibbs CH","year":"1966"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.14219\/jada.archive.1975.0164"},{"issue":"10","key":"e_1_2_9_14_1","first-page":"656","article-title":"Clinical and instrumental functional analysis for diagnosis and treatment planning. Part 5. Axiography","volume":"22","author":"Slavicek R","year":"1988","journal-title":"J Clin Orthod"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0096-6347(40)90353-2"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.14219\/jada.archive.1953.0070"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(54)90089-X"},{"key":"e_1_2_9_18_1","first-page":"395","article-title":"A method of recording the movement of a point on the jaw","volume":"29","author":"Lewin A","year":"1974","journal-title":"J Dent Assoc S Afr"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.3109\/00016357709055998"},{"key":"e_1_2_9_20_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-849X.2009.00510.x"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(78)80106-1"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(63)90133-1"},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(63)90134-3"},{"key":"e_1_2_9_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(63)90231-2"},{"key":"e_1_2_9_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(00)80017-7"},{"key":"e_1_2_9_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2006.07.007"},{"key":"e_1_2_9_27_1","first-page":"65e","article-title":"The virtual craniofacial patient: 3D jaw modeling and animation","volume":"94","author":"Enciso R","year":"2003","journal-title":"Stud Health Technol Inform"},{"key":"e_1_2_9_28_1","first-page":"65","article-title":"SICAT function: anatomical real\u2010dynamic articulation by merging cone beam computed tomography and jaw motion tracking data","volume":"17","author":"Hanssen N","year":"2014","journal-title":"Int J Comput Dent"},{"key":"e_1_2_9_29_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.12389"},{"key":"e_1_2_9_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpor.2018.05.001"},{"key":"e_1_2_9_31_1","article-title":"Modjaw\u00ae device: analysis of mandibular kinematics recorded for a group of asymptomatic subjects","volume":"1","author":"Bapelle M","year":"2021","journal-title":"Cranio"},{"key":"e_1_2_9_32_1","doi-asserted-by":"publisher","DOI":"10.11607\/ijp.7126"},{"key":"e_1_2_9_33_1","article-title":"Digital maxillomandibular relationship and mandibular motion recording by using an optical jaw tracking system to acquire a dynamic virtual patient","author":"Revilla\u2010Le\u00f3n M","year":"2022","journal-title":"J Prosthet Dent"},{"key":"e_1_2_9_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2022.08.036"},{"key":"e_1_2_9_35_1","doi-asserted-by":"publisher","DOI":"10.3934\/mbe.2020307"},{"key":"e_1_2_9_36_1","doi-asserted-by":"publisher","DOI":"10.1145\/3306346.3323044"},{"issue":"3","key":"e_1_2_9_37_1","first-page":"278","article-title":"Automated digital dental articulation","volume":"13","author":"Xia JJ","year":"2010","journal-title":"Med Image Comput Comput Assist Interv"},{"key":"e_1_2_9_38_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdsr.2009.04.001"},{"key":"e_1_2_9_39_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.adaj.2021.05.018"},{"issue":"2","key":"e_1_2_9_40_1","first-page":"173","article-title":"Accuracy and reproducibility of the visualization of occlusal contact points using analog articulating foil or digital intraoral scanners in vitro","volume":"25","author":"Hennen MV","year":"2022","journal-title":"Int J Comput Dent"},{"key":"e_1_2_9_41_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2022.104355"},{"key":"e_1_2_9_42_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.13096"},{"key":"e_1_2_9_43_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2019.11.014"},{"key":"e_1_2_9_44_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2018.01.024"},{"key":"e_1_2_9_45_1","doi-asserted-by":"publisher","DOI":"10.1067\/mpr.2002.129379"},{"key":"e_1_2_9_46_1","first-page":"185","article-title":"Comparison of the duration of occlusal contacts during habitual closure using the digital occlusal sensor","volume":"65","author":"Maness WL","year":"1986","journal-title":"J Dent Res"},{"key":"e_1_2_9_47_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(85)90265-3"},{"key":"e_1_2_9_48_1","first-page":"17","article-title":"Sensitivity and reliability of the t\u2010scan system for occlusal analysis","volume":"6","author":"Hsu ML","year":"1992","journal-title":"J Craniomandib Disord"},{"key":"e_1_2_9_49_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2020.07.024"},{"key":"e_1_2_9_50_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2842.2007.01820.x"},{"key":"e_1_2_9_51_1","first-page":"306e","volume-title":"Science and Practice of Occlusion","author":"McNeill C","year":"1997"},{"key":"e_1_2_9_52_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(75)90045-1"},{"key":"e_1_2_9_53_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(05)80161-1"},{"key":"e_1_2_9_54_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(96)90172-9"},{"key":"e_1_2_9_55_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2015.05.013"},{"key":"e_1_2_9_56_1","doi-asserted-by":"publisher","DOI":"10.1111\/joor.12618"},{"key":"e_1_2_9_57_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2022.05.025"},{"key":"e_1_2_9_58_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(85)80086-X"},{"key":"e_1_2_9_59_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(93)90215-A"},{"key":"e_1_2_9_60_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(86)90188-5"},{"key":"e_1_2_9_61_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.sodo.2006.01.007"},{"key":"e_1_2_9_62_1","doi-asserted-by":"publisher","DOI":"10.4317\/jced.50680"},{"key":"e_1_2_9_63_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2022.09.005"},{"key":"e_1_2_9_64_1","doi-asserted-by":"publisher","DOI":"10.11607\/ijp.7407"},{"key":"e_1_2_9_65_1","article-title":"A guide for maximizing the accuracy of intraoral digital scans. Part 1: operator factors","author":"Revilla\u2010Le\u00f3n M","year":"2022","journal-title":"J Esthet Restor Dent"},{"key":"e_1_2_9_66_1","article-title":"A guide for maximizing the accuracy of intraoral digital scans. Part 2: patient factors","author":"Revilla\u2010Le\u00f3n M","year":"2022","journal-title":"J Esthet Restor Dent"},{"key":"e_1_2_9_67_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2022.01.012"},{"key":"e_1_2_9_68_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2019.06.003"},{"key":"e_1_2_9_69_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2019.06.004"},{"key":"e_1_2_9_70_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00784-022-04607-6"},{"key":"e_1_2_9_71_1","doi-asserted-by":"publisher","DOI":"10.1093\/ejo\/cjw033"},{"key":"e_1_2_9_72_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2021.03.007"},{"key":"e_1_2_9_73_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.13135"},{"key":"e_1_2_9_74_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2018.10.007"},{"key":"e_1_2_9_75_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.13526"},{"key":"e_1_2_9_76_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2022.09.004"},{"issue":"3","key":"e_1_2_9_77_1","first-page":"283","article-title":"Sources of error in maximum intercuspation from complete dentate full\u2010arch intraoral scans in vitro","volume":"24","author":"Osnes C","year":"2021","journal-title":"Int J Comput Dent"},{"key":"e_1_2_9_78_1","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2010.2049526"},{"key":"e_1_2_9_79_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joms.2011.02.109"},{"key":"e_1_2_9_80_1","doi-asserted-by":"publisher","DOI":"10.1111\/joor.12374"},{"key":"e_1_2_9_81_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2021.02.010"},{"key":"e_1_2_9_82_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2021.06.001"},{"key":"e_1_2_9_83_1","article-title":"Artificial intelligence applications in implant dentistry: a systematic review","author":"Revilla\u2010Le\u00f3n M","year":"2021","journal-title":"J Prosthet Dent"},{"key":"e_1_2_9_84_1","doi-asserted-by":"publisher","DOI":"10.1044\/2014_JSLHR-S-13-0007"},{"key":"e_1_2_9_85_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00784-022-04835-w"},{"key":"e_1_2_9_86_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2020.109994"},{"key":"e_1_2_9_87_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2023.104478"},{"key":"e_1_2_9_88_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(82)90367-5"},{"key":"e_1_2_9_89_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2018.12.012"},{"key":"e_1_2_9_90_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2842.2011.02277.x"},{"key":"e_1_2_9_91_1","doi-asserted-by":"publisher","DOI":"10.1111\/joor.12284"},{"key":"e_1_2_9_92_1","doi-asserted-by":"publisher","DOI":"10.4047\/jap.2020.12.2.49"},{"key":"e_1_2_9_93_1","doi-asserted-by":"publisher","DOI":"10.1111\/joor.12905"},{"key":"e_1_2_9_94_1","doi-asserted-by":"publisher","DOI":"10.1111\/joor.12543"}],"container-title":["Journal of Esthetic and Restorative Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jerd.13044","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,5]],"date-time":"2023-10-05T15:15:15Z","timestamp":1696518915000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jerd.13044"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4,6]]},"references-count":93,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2023,7]]}},"alternative-id":["10.1111\/jerd.13044"],"URL":"https:\/\/doi.org\/10.1111\/jerd.13044","archive":["Portico"],"relation":{},"ISSN":["1496-4155","1708-8240"],"issn-type":[{"value":"1496-4155","type":"print"},{"value":"1708-8240","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,4,6]]},"assertion":[{"value":"2023-01-20","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-03-25","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-04-06","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}