{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T03:34:23Z","timestamp":1789011263640,"version":"build-2803163510"},"reference-count":37,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2026,2,25]],"date-time":"2026-02-25T00:00:00Z","timestamp":1771977600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2026,2,25]],"date-time":"2026-02-25T00:00:00Z","timestamp":1771977600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Esthet Restor Dent"],"published-print":{"date-parts":[[2026,7]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>Despite the widespread clinical use of digital scanning, its accuracy for complete\u2010arch implant impressions remains controversial. This study aimed to investigate the feasibility and clinical performance of an artificial intelligence (AI)\u2013guided navigation photogrammetry system for intraoperative complete\u2010arch impression and immediate loading.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods<\/jats:title>\n                    <jats:p>\n                      Patients requiring complete\u2010arch rehabilitation in either jaw were treated between July and December 2024. After navigation surgery, photogrammetry scanning was performed, and AI automatically compiled patient data, including implant coordinates, preoperative anatomy, digital wax\u2010up, all referenced within the same\n                      <jats:italic>X<\/jats:italic>\n                      ,\n                      <jats:italic>Y<\/jats:italic>\n                      ,\n                      <jats:italic>Z<\/jats:italic>\n                      system. A monolithic three\u2010dimensional (3D) printed screw\u2010retained temporary prosthesis was delivered. Prosthetic fit was clinically and radiographically assessed and the extent of occlusal adjustment was measured. Scanning time, patient\u2010reported outcomes (comfort, esthetics), and any biological and mechanical complications at 6\u2009months were reported with descriptive statistics. To investigate whether the number of implants (4 vs. 6) and type of arch (maxilla vs. mandible) significantly affected impression\u2010taking time, independent two\u2010tailed\n                      <jats:italic>t<\/jats:italic>\n                      \u2010tests were conducted (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Nineteen patients were treated with 24 complete\u2010arch prostheses (maxillary\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200914, mandibular\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200910) supported by 6 (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200910) or 4 (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200914) implants. The scanning time was 10.21\u2009\u00b1\u20091.02 and 27.73\u2009\u00b1\u20099.29\u2009s for four and six implants, respectively. Type of arch did not affect scanning time (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&gt;\u20090.05). A high level of esthetic satisfaction (8.91\u2009\u00b1\u20090.93) and comfort (8.08\u2009\u00b1\u20090.88) were reported. All prostheses were deemed to have passive fit, with no detectable marginal or radiographic gaps. Mean occlusal adjustment was 692.17\u2009\u00b1\u2009247.43\u2009\u03bcm, classified as moderate. No biological and mechanical complications were reported.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Within the limitations of this study, navigation photogrammetry and its AI\u2010driven digital workflow were reliable for quick and efficient intraoperative complete\u2010arch implant impression in both jaws. The implant number was the only variable to significantly influence scanning time. All 3D\u2010printed screw\u2010retained temporary prostheses were accurately fitted with moderate occlusal adjustments and immediately loaded. This approach eliminates chairside conversion or relining, potentially reducing treatment time. High patient satisfaction was reported.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/jerd.70131","type":"journal-article","created":{"date-parts":[[2026,3,8]],"date-time":"2026-03-08T10:24:06Z","timestamp":1772965446000},"page":"1265-1275","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["<scp>AI<\/scp>\n                    \u2010Powered Intraoperative Navigation Photogrammetry for Complete\u2010Arch Implant Impression and Immediate Loading With a\n                    <scp>3D<\/scp>\n                    \u2010Printed Temporary Prosthesis: A Prospective Clinical Study"],"prefix":"10.1111","volume":"38","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3052-8186","authenticated-orcid":false,"given":"Alessandro","family":"Pozzi","sequence":"first","affiliation":[{"name":"Department of Clinical Science and Translational Medicine University of Rome Tor Vergata  Rome Italy"},{"name":"Department of Restorative Sciences Dental College of Georgia at Augusta University  Augusta Georgia USA"},{"name":"Department of Restorative Dentistry and Biomaterials Sciences Harvard School of Dental Medicine  Boston Massachusetts USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea","family":"Laureti","sequence":"additional","affiliation":[{"name":"Department of Chemical Science and Technologies University of Rome Tor Vergata  Rome Italy"},{"name":"Division of Fixed Prosthodontics and Biomaterials University Clinics for Dental Medicine, University of Geneva  Geneva Switzerland"},{"name":"Department of Periodontics &amp; Oral Medicine University of Michigan School of Dentistry  Ann Arbor Michigan USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6152-3337","authenticated-orcid":false,"given":"Lorenzo","family":"Arcuri","sequence":"additional","affiliation":[{"name":"Department of Life Science, Health and Health Professions Link Campus University  Rome Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard","family":"Ansong","sequence":"additional","affiliation":[{"name":"Private Practice  Oviedo Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jimmy","family":"Londono","sequence":"additional","affiliation":[{"name":"Department of Restorative Sciences The Dental College of Georgia at Augusta University  Augusta Georgia USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2966-0067","authenticated-orcid":false,"given":"James","family":"Chow","sequence":"additional","affiliation":[{"name":"Br\u00e5nemark Osseointegration Centre  Hong Kong Hong Kong"},{"name":"Hong Kong University  Hong Kong Hong Kong"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,2,25]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2021.04.026"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.11607\/jomi.9710"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.14047"},{"issue":"1","key":"e_1_2_10_5_1","first-page":"101","article-title":"Accuracy of Digital Implant Impressions With Intraoral Scanners. A Systematic Review","volume":"10","author":"Rutkunas V.","year":"2017","journal-title":"European Journal of Oral Implantology"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.14219\/jada.2013.45"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1922\/EJPRD_2481Rutkunas12"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.14141"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40729-021-00352-9"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.12994"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.13273"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12903-017-0383-4"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.3390\/app11219859"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.13264"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.13666"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.11607\/jomi.10266"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.1111\/cid.13336"},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2022.08.028"},{"key":"e_1_2_10_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2022.104266"},{"issue":"1","key":"e_1_2_10_20_1","first-page":"19","article-title":"Effect of Splinting Scan Bodies on Trueness of Complete\u2010Arch Implant Impression Using Different Intraoral Scanners: An In\u00a0Vitro Study","volume":"26","author":"Retana L.","year":"2023","journal-title":"International Journal of Computerized Dentistry"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.70001"},{"key":"e_1_2_10_22_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.14463"},{"key":"e_1_2_10_23_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.13598"},{"key":"e_1_2_10_24_1","doi-asserted-by":"publisher","DOI":"10.1111\/cid.13338"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.13604"},{"key":"e_1_2_10_26_1","doi-asserted-by":"publisher","DOI":"10.1111\/cid.70059"},{"key":"e_1_2_10_27_1","doi-asserted-by":"publisher","DOI":"10.1111\/cid.70049"},{"key":"e_1_2_10_28_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.14445"},{"key":"e_1_2_10_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2020.03.005"},{"key":"e_1_2_10_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2025.03.041"},{"key":"e_1_2_10_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2025.03.047"},{"key":"e_1_2_10_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclinepi.2007.11.008"},{"key":"e_1_2_10_33_1","doi-asserted-by":"publisher","DOI":"10.1038\/sdata.2016.18"},{"key":"e_1_2_10_34_1","doi-asserted-by":"publisher","DOI":"10.1111\/cid.13360"},{"key":"e_1_2_10_35_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2020.10.024"},{"key":"e_1_2_10_36_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.13519"},{"issue":"5","key":"e_1_2_10_37_1","first-page":"596","article-title":"A Combined Digital and Stereophotogrammetric Technique for Rehabilitation With Immediate Loading of Complete\u2010Arch, Implant\u2010Supported Prostheses: A Randomized Controlled Pilot Clinical Trial","volume":"118","author":"Penarrocha\u2010Diago M.","year":"2017","journal-title":"Journal of Prosthetic Dentistry"},{"key":"e_1_2_10_38_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.13751"}],"container-title":["Journal of Esthetic and Restorative Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jerd.70131","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/jerd.70131","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jerd.70131","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T17:15:58Z","timestamp":1787591758000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jerd.70131"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,25]]},"references-count":37,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2026,7]]}},"alternative-id":["10.1111\/jerd.70131"],"URL":"https:\/\/doi.org\/10.1111\/jerd.70131","archive":["Portico"],"relation":{},"ISSN":["1496-4155","1708-8240"],"issn-type":[{"value":"1496-4155","type":"print"},{"value":"1708-8240","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,25]]},"assertion":[{"value":"2025-09-12","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-02-13","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-02-25","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}