{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T15:29:56Z","timestamp":1786634996858,"version":"build-2736575974"},"reference-count":20,"publisher":"Wiley","issue":"9","license":[{"start":{"date-parts":[[2026,3,7]],"date-time":"2026-03-07T00:00:00Z","timestamp":1772841600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2026,3,7]],"date-time":"2026-03-07T00:00:00Z","timestamp":1772841600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Esthet Restor Dent"],"published-print":{"date-parts":[[2026,9]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Statement of Problem<\/jats:title>\n                    <jats:p>Additively manufactured interim restorative materials are being employed to meet contemporary esthetic demands, yet the longevity of their optical characteristics remains uncertain.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To assess the impact of material composition and manufacturing method on the optical stability of different additively manufactured interim restorative resins under in\u00a0vitro aging methods and compare these properties to those of milled hybrid ceramic blocks.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods<\/jats:title>\n                    <jats:p>\n                      A total of 240 disc\u2010shaped specimens (diameter 10.00 \u00b1\u20090.05\u2009mm, thickness 1.10 \u00b1\u20090.05\u2009mm) were fabricated utilizing four additively manufactured resin\u2010based and two milled hybrid ceramic blocks. Following standardized finishing and polishing processes, the specimens were aged in coffee at 55\u00b0C, grape juice at 5\u00b0C, deionized water at 25\u00b0C, or thermocycled between 5\u00b0C and 55\u00b0C. Color stability (\n                      <jats:styled-content style=\"fixed-case\">\n                        \u0394E\n                        <jats:sub>00<\/jats:sub>\n                      <\/jats:styled-content>\n                      ) and relative translucency parameter (\n                      <jats:styled-content style=\"fixed-case\">\n                        RTP\n                        <jats:sub>00<\/jats:sub>\n                      <\/jats:styled-content>\n                      ) were evaluated. Data was analyzed with two\u2010way\n                      <jats:styled-content style=\"fixed-case\">ANOVA<\/jats:styled-content>\n                      and Tukey's post\u2010hoc tests (\n                      <jats:italic>\u03b1<\/jats:italic>\n                      \u2009=\u20090.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Material type significantly affected the color and translucency following aging (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001). Among additively manufactured materials, Primeprint Temp demonstrated the least color change (\u0394E\n                      <jats:styled-content style=\"fixed-case\">\n                        <jats:sub>00<\/jats:sub>\n                      <\/jats:styled-content>\n                      \u2009=\u20094.30\u2009\u00b1\u20091.10), while Ceramic Crown Resin showed the most significant discoloration (\u0394E\n                      <jats:styled-content style=\"fixed-case\">\n                        <jats:sub>00<\/jats:sub>\n                      <\/jats:styled-content>\n                      \u2009=\u200913.52\u2009\u00b1\u20091.40). Furthermore, the milled hybrid ceramic material (Enamic) exhibited the lowest overall color change across all tested materials. Ceramic Crown Resin exhibited the most significant reduction in the relative translucency parameter (\u0394RTP\n                      <jats:styled-content style=\"fixed-case\">\n                        <jats:sub>00<\/jats:sub>\n                      <\/jats:styled-content>\n                      \u2009=\u2009\u22122.70\u2009\u00b1\u20090.55), exceeding the acceptability threshold of 2.6 following immersion in coffee.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Primeprint Temp demonstrated superior color and translucency stability relative to the other materials examined, whereas Ceramic Crown Resin showed the least stability, particularly under the conditions of coffee immersion.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical Significance<\/jats:title>\n                    <jats:p>Understanding the optical stability of contemporary interim additively manufactured resins facilitates enhanced esthetic stability between sessions and minimizes the necessity for repolishing or remaking interim restorations. Patients who frequently consume hot, staining beverages should be warned about potential discoloration, especially when utilizing resin\u2010based materials for long\u2010term use.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/jerd.70137","type":"journal-article","created":{"date-parts":[[2026,3,8]],"date-time":"2026-03-08T19:10:36Z","timestamp":1772997036000},"page":"1766-1772","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Color and Translucency Stability of Additively Manufactured Interim Dental Restorative Materials: An In\u00a0Vitro Aging Simulation Study"],"prefix":"10.1111","volume":"38","author":[{"given":"Fadi","family":"Bitar","sequence":"first","affiliation":[{"name":"Department of Restorative Sciences University of North Carolina, Adams School of Dentistry  Chapel Hill North Carolina USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8774-9764","authenticated-orcid":false,"given":"Tariq","family":"Alsahafi","sequence":"additional","affiliation":[{"name":"Department of Restorative Sciences University of North Carolina, Adams School of Dentistry  Chapel Hill North Carolina USA"},{"name":"Department of Conservative Dentistry, College of Dentistry Qassim University  Qassim Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean\u2010Pierre","family":"Albouy","sequence":"additional","affiliation":[{"name":"Department of Restorative Sciences University of North Carolina, Adams School of Dentistry  Chapel Hill North Carolina USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2610-5471","authenticated-orcid":false,"given":"Adalberto","family":"Vasconcellos","sequence":"additional","affiliation":[{"name":"Department of Restorative Sciences University of North Carolina, Adams School of Dentistry  Chapel Hill North Carolina USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3826-316X","authenticated-orcid":false,"given":"Taiseer A.","family":"Sulaiman","sequence":"additional","affiliation":[{"name":"Department of Restorative Sciences University of North Carolina, Adams School of Dentistry  Chapel Hill North Carolina USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,3,7]]},"reference":[{"key":"e_1_2_9_2_1","unstructured":"C. W.Hull \u201cApparatus for Production of Three\u2010Dimensional Objects by Stereolithography \u201d1986US Patent US4575330A https:\/\/patents.google.com\/patent\/US4575330A\/en."},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/jerd.13331"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/jerd.12640"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/jerd.12904"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.3390\/ma14030650"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1007\/s44411\u2010024\u201000011\u20106"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2023.104458"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.3390\/polym13234102"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.2341\/21\u2010077\u2010L"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2025.105734"},{"key":"e_1_2_9_12_1","volume-title":"Colorimetry","author":"International Commission on Illumination","year":"2004"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1111\/jerd.12149"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.3390\/polym15061443"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1111\/jerd.13125"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2018.05.001"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.1111\/jerd.13382"},{"key":"e_1_2_9_18_1","volume-title":"Colorimetry\u2014Part 6: CIEDE2000 Colour\u2010Difference Formula","author":"ISO\/CIE 11664\u20136:2022","year":"2022"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdsr.2019.09.004"},{"key":"e_1_2_9_20_1","doi-asserted-by":"publisher","DOI":"10.3390\/ma18081812"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.3109\/00016357.2013.856467"}],"container-title":["Journal of Esthetic and Restorative Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jerd.70137","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/jerd.70137","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jerd.70137","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T14:40:31Z","timestamp":1786632031000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jerd.70137"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,7]]},"references-count":20,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2026,9]]}},"alternative-id":["10.1111\/jerd.70137"],"URL":"https:\/\/doi.org\/10.1111\/jerd.70137","archive":["Portico"],"relation":{},"ISSN":["1496-4155","1708-8240"],"issn-type":[{"value":"1496-4155","type":"print"},{"value":"1708-8240","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,7]]},"assertion":[{"value":"2025-06-11","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-02-26","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-03-07","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}