{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T13:04:26Z","timestamp":1769087066949,"version":"3.49.0"},"reference-count":16,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2018,6,19]],"date-time":"2018-06-19T00:00:00Z","timestamp":1529366400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J of Cosmetic Dermatology"],"published-print":{"date-parts":[[2019,2]]},"abstract":"<jats:title>Summary<\/jats:title><jats:sec><jats:title>Objectives<\/jats:title><jats:p>To compare the amount of tissue loss using different <jats:styled-content style=\"fixed-case\">FUE<\/jats:styled-content> punches.<\/jats:p><\/jats:sec><jats:sec><jats:title>Materials and Methods<\/jats:title><jats:p>The study was conducted in 5 patients undergoing hair restoration surgery by <jats:styled-content style=\"fixed-case\">FUE<\/jats:styled-content>. Four different kinds of punches were used, that is, sharp, blunt, serrated, and new \u201cA\u2010design.\u201d All the punches had a total cutting edge of 0.8\u00a0mm. In each patient, 4 punches were used to make insertion at right angle with the skin. Immediately after the punch use, the diameter of the hole was measured. The same areas were also measured after 24\u00a0hours and after 1\u00a0month. The data were collected and analyzed by Multiple <jats:italic>t<\/jats:italic> test (with Bonferroni's correction).<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The average size of the wound immediately at the end of the procedure was 0.826\u00a0mm for sharp, 0.858\u00a0mm for blunt, 0.892\u00a0mm for serrated, and 0.932\u00a0mm for A\u2010design. Similarly, the wounds decreased to 0.752, 0.778, 0.774, and 0.696\u00a0mm for sharp, blunt, serrated, and A\u2010design, respectively, after 24\u00a0hours. The final wound\/scar size was 0.640\u00a0mm for punch, 0.660\u00a0mm for blunt punch, 0.668\u00a0mm for serrated punch, and 0.598\u00a0mm for A\u2010design punch after 1\u00a0month.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The new A\u2010design resulted in the minimum scar size after 1\u00a0month.<\/jats:p><\/jats:sec>","DOI":"10.1111\/jocd.12538","type":"journal-article","created":{"date-parts":[[2018,6,19]],"date-time":"2018-06-19T21:08:12Z","timestamp":1529442492000},"page":"303-307","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Comparison of tissue loss by different punches: A new A\u2010design"],"prefix":"10.1111","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0251-688X","authenticated-orcid":false,"given":"Muhammad","family":"Ahmad","sequence":"first","affiliation":[{"name":"Aesthetic Plastic Surgery &amp; Hair Transplant Institute Islamabad Pakistan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2018,6,19]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1177\/074880680802500408"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1524-4725.2002.01320.x"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/1524-4725.2006.32006"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.fsc.2013.05.009"},{"key":"e_1_2_7_6_1","volume-title":"Hair Transplantation","author":"Rassman W","year":"2006"},{"key":"e_1_2_7_7_1","doi-asserted-by":"crossref","first-page":"133","DOI":"10.33589\/26.4.0129a","article-title":"Powered FU extraction with the short\u2010Arc oscillation flat punch FUE system (SFFS)","volume":"26","author":"Devroye J","year":"2016","journal-title":"Hair Transpl Forum Int"},{"key":"e_1_2_7_8_1","doi-asserted-by":"crossref","first-page":"157","DOI":"10.33589\/14.5.0157","article-title":"The SAFE system: new instrumentation and methodology to improve follicular unit extraction (FUE)","volume":"14","author":"Harris JA","year":"2004","journal-title":"Hair Transpl Forum Int"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.4172\/2161-0991.1000158"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1097\/DSS.0000000000000742"},{"key":"e_1_2_7_11_1","doi-asserted-by":"crossref","first-page":"254","DOI":"10.33589\/26.6.0254","article-title":"Another way to look at donor harvesting effects with FUE","volume":"26","author":"Rose PT","year":"2016","journal-title":"Hair Transpl Forum Int"},{"key":"e_1_2_7_12_1","doi-asserted-by":"crossref","first-page":"162","DOI":"10.33589\/16.5.0162","article-title":"The FUExtractor system: new instrumentation to improve follicular unit extraction","volume":"16","author":"Boudjema P","year":"2006","journal-title":"Hair Transpl Forum Int"},{"key":"e_1_2_7_13_1","unstructured":"ColeJP.Personal communication with multiple physicians. 5\/2006."},{"key":"e_1_2_7_14_1","unstructured":"ColeJP.A review of follicular unit extraction: FUE.www.coleinstruments.com\/fue-review-follicular-init-extraction-hair-transplant.html. Accessed November 25 2017."},{"key":"e_1_2_7_15_1","first-page":"1","article-title":"Follicular transection rates in follicular units extraction method","volume":"12","author":"Mahapatra S","year":"2017","journal-title":"J Stem Cell"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaad.2014.07.058"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1111\/jocd.12267"}],"container-title":["Journal of Cosmetic Dermatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fjocd.12538","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jocd.12538","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/jocd.12538","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jocd.12538","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,9]],"date-time":"2023-09-09T09:16:12Z","timestamp":1694250972000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jocd.12538"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,6,19]]},"references-count":16,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,2]]}},"alternative-id":["10.1111\/jocd.12538"],"URL":"https:\/\/doi.org\/10.1111\/jocd.12538","archive":["Portico"],"relation":{},"ISSN":["1473-2130","1473-2165"],"issn-type":[{"value":"1473-2130","type":"print"},{"value":"1473-2165","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,6,19]]},"assertion":[{"value":"2018-03-02","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-06-19","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}