{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T16:50:37Z","timestamp":1760028637615},"reference-count":24,"publisher":"Hindawi Limited","issue":"2","license":[{"start":{"date-parts":[[2013,12,12]],"date-time":"2013-12-12T00:00:00Z","timestamp":1386806400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2013,12,12]],"date-time":"2013-12-12T00:00:00Z","timestamp":1386806400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Card Surg"],"published-print":{"date-parts":[[2014,3]]},"DOI":"10.1111\/jocs.12265","type":"journal-article","created":{"date-parts":[[2013,12,12]],"date-time":"2013-12-12T11:06:46Z","timestamp":1386846406000},"page":"127-133","source":"Crossref","is-referenced-by-count":12,"title":["Moderate Patient-Prosthesis Mismatch Predicts Cardiac Events and Advanced Functional Class in Young and Middle-Aged Patients Undergoing Surgery Due to Severe Aortic Stenosis"],"prefix":"10.1155","volume":"29","author":[{"given":"Daniel","family":"Hernandez-Vaquero","sequence":"first","affiliation":[{"name":"Department of Cardiac Surgery; Central Universitary Hospital of Asturias; Oviedo Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jose M.","family":"Garcia","sequence":"additional","affiliation":[{"name":"Department of Cardiology; Central Universitary Hospital of Asturias; Oviedo Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rocio","family":"Diaz","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery; Central Universitary Hospital of Asturias; Oviedo Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Calvo","sequence":"additional","affiliation":[{"name":"Department of Cardiology; Central Universitary Hospital of Asturias; Oviedo Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zain","family":"Khalpey","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery, College of Medicine; University of Arizona; Tucson Arizona"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ernesto","family":"Hern\u00e1ndez","sequence":"additional","affiliation":[{"name":"Department of Cardiology; Hospital of Cabue\u00f1es; Gij\u00f3n Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"V\u00edctor","family":"Rodriguez","sequence":"additional","affiliation":[{"name":"Department of Cardiology; Hospital San Agust\u00edn; Avil\u00e9s Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C\u00e9sar","family":"Mor\u00eds","sequence":"additional","affiliation":[{"name":"Department of Cardiology; Central Universitary Hospital of Asturias; Oviedo Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Juan C.","family":"Llosa","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery; Central Universitary Hospital of Asturias; Oviedo Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"98","published-online":{"date-parts":[[2013,12,12]]},"reference":[{"key":"10.1111\/jocs.12265-BIB0001|jocs12265-cit-0001","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1161\/01.CIR.58.1.20","article-title":"The problem of valve prosthesis-patient mismatch","volume":"58","author":"Rahimtoola","year":"1978","journal-title":"Circulation"},{"key":"10.1111\/jocs.12265-BIB0002|jocs12265-cit-0002","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/j.jacc.2008.09.022","article-title":"Impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement: Influence of age, obesity and left ventricular dysfunction","volume":"53","author":"Mohty","year":"2009","journal-title":"J Am Coll Cardiol"},{"key":"10.1111\/jocs.12265-BIB0003|jocs12265-cit-0003","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1136\/hrt.2006.107672","article-title":"Prevention of valve prosthesis-patient mismatch before aortic valve replacement: Does it matter and is it feasible","volume":"93","author":"Pibarot","year":"2007","journal-title":"Heart"},{"key":"10.1111\/jocs.12265-BIB0004|jocs12265-cit-0004","doi-asserted-by":"crossref","first-page":"1022","DOI":"10.1136\/hrt.2005.067363","article-title":"Prosthesis-patient mismatch: Definition, clinical impact, and prevention","volume":"92","author":"Pibarot","year":"2006","journal-title":"Heart"},{"key":"10.1111\/jocs.12265-BIB0005|jocs12265-cit-0005","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1016\/S0300-8932(10)70058-0","article-title":"Prevention of moderate prosthesis-patient mismatch: Individualization vs generalization","volume":"63","author":"Dumesnil","year":"2010","journal-title":"Rev Esp Cardiol"},{"key":"10.1111\/jocs.12265-BIB0006|jocs12265-cit-0006","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1016\/j.athoracsur.2005.07.084","article-title":"Prosthesis-patient mismatch after aortic valve replacement: Impact on age and body size on late survival","volume":"81","author":"Moon","year":"2006","journal-title":"Ann Thorac Surg"},{"key":"10.1111\/jocs.12265-BIB0007|jocs12265-cit-0007","doi-asserted-by":"crossref","first-page":"2003","DOI":"10.1016\/S0003-4975(02)04034-1","article-title":"Hemodynamics and early clinical performance of the St. Jude Medical Regent mechanical aortic valve","volume":"74","author":"Bach","year":"2002","journal-title":"Ann Thorac Surg"},{"key":"10.1111\/jocs.12265-BIB0008|jocs12265-cit-0008","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1016\/0735-1097(93)90681-P","article-title":"Echocardiographic description of the CarboMedics bileaflet prosthetic heart valve","volume":"21","author":"Chambers","year":"1993","journal-title":"J Am Coll Cardiol"},{"key":"10.1111\/jocs.12265-BIB0009|jocs12265-cit-0009","doi-asserted-by":"crossref","first-page":"759","DOI":"10.1016\/j.jtcvs.2005.02.057","article-title":"A randomized comparison of the MCRI On-X and CarboMedics Top Hat bileaflet mechanical replacement aortic valves: Early postoperative hemodynamic function and clinical events","volume":"130","author":"Chambers","year":"2005","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1111\/jocs.12265-BIB0010|jocs12265-cit-0010","first-page":"569","article-title":"Early postoperative echocardiographic hemodynamic performance of the On-X prosthetic heart valve: A multicenter study","volume":"7","author":"Chambers","year":"1998","journal-title":"J Heart Valve Dis"},{"key":"10.1111\/jocs.12265-BIB0011|jocs12265-cit-0011","doi-asserted-by":"crossref","first-page":"570","DOI":"10.1161\/CIRCULATIONAHA.105.587022","article-title":"Impact of patient-prosthesis mismatch on cardiac events and midterm mortality after aortic valve replacement in patients with pure aortic stenosis","volume":"113","author":"Tasca","year":"2006","journal-title":"Circulation"},{"key":"10.1111\/jocs.12265-BIB0012|jocs12265-cit-0012","first-page":"661","article-title":"An echocardiographic description of the Sulzer Carbomedics Synergy ST (Labcor) porcine valve in the aortic position","volume":"9","author":"Chambers","year":"2000","journal-title":"J Heart Valve Dis"},{"key":"10.1111\/jocs.12265-BIB0013|jocs12265-cit-0013","doi-asserted-by":"crossref","first-page":"S265","DOI":"10.1016\/S0003-4975(01)02509-7","article-title":"Patient-prosthesis mismatch can be predicted at the time of operation","volume":"71","author":"Pibarot","year":"2001","journal-title":"Ann Thorac Surg"},{"key":"10.1111\/jocs.12265-BIB0014|jocs12265-cit-0014","doi-asserted-by":"crossref","first-page":"1131","DOI":"10.1016\/S0735-1097(00)00859-7","article-title":"Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention","volume":"36","author":"Pibarot","year":"2000","journal-title":"J Am Coll Cardiol"},{"key":"10.1111\/jocs.12265-BIB0015|jocs12265-cit-0015","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1161\/01.CIR.102.suppl_3.III-5","article-title":"Prosthesis-patient mismatch affects survival after aortic valve replacement","volume":"102","author":"Rao","year":"2000","journal-title":"Circulation"},{"key":"10.1111\/jocs.12265-BIB0016|jocs12265-cit-0016","first-page":"475","article-title":"The influence of patient-prosthesis mismatch on in-hospital complications and early mortality after aortic valve replacement","volume":"16","author":"Nozohoor","year":"2007","journal-title":"J Heart Valve Dis"},{"key":"10.1111\/jocs.12265-BIB0017|jocs12265-cit-0017","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1016\/j.athoracsur.2009.07.037","article-title":"Patient-prosthesis mismatch in patients with aortic stenosis undergoing isolated aortic valve replacement does not affect survival","volume":"89","author":"Howell","year":"2010","journal-title":"Ann Thorac Surg"},{"key":"10.1111\/jocs.12265-BIB0018|jocs12265-cit-0018","doi-asserted-by":"crossref","first-page":"774","DOI":"10.1016\/j.recesp.2011.05.008","article-title":"Influence of patient-prosthesis mismatch in the octogenarian undergoing surgery for aortic valve replacement due to severe stenosis","volume":"64","author":"Hernandez-Vaquero","year":"2011","journal-title":"Rev Esp Cardiol"},{"key":"10.1111\/jocs.12265-BIB0019|jocs12265-cit-0019","doi-asserted-by":"crossref","first-page":"1791","DOI":"10.1016\/j.athoracsur.2008.09.005","article-title":"Prosthesis-patient mismatch in the elderly: Survival, ventricular mass regression, and quality of life","volume":"86","author":"Vicchio","year":"2008","journal-title":"Ann Thorac Surg"},{"key":"10.1111\/jocs.12265-BIB0020|jocs12265-cit-0020","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1007\/s11748-008-0255-6","article-title":"Patient-prosthesis mismatch after aortic valve replacement in the elderly","volume":"56","author":"Ryomoto","year":"2008","journal-title":"Gen Thorac Cardiovasc Surg"},{"key":"10.1111\/jocs.12265-BIB0021|jocs12265-cit-0021","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1136\/hrt.2007.116673","article-title":"Impact of patient-prosthesis mismatch on exercise capacity in patients after bioprosthetic valve replacement","volume":"94","author":"Bleiziffer","year":"2008","journal-title":"Heart"},{"key":"10.1111\/jocs.12265-BIB0022|jocs12265-cit-0022","first-page":"522","article-title":"Cardiopulmonary exercise testing in patients with 21\u2009mm St. Jude Medical aortic prosthesis","volume":"8","author":"De Carlo","year":"1999","journal-title":"J Heart Valve Dis"},{"key":"10.1111\/jocs.12265-BIB0023|jocs12265-cit-0023","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1136\/hrt.2006.102764","article-title":"Prediction of valve prosthesis-patient mismatch prior to aortic valve replacement: Which is the best method","volume":"93","author":"Bleiziffer","year":"2007","journal-title":"Heart"},{"key":"10.1111\/jocs.12265-BIB0024|jocs12265-cit-0024","doi-asserted-by":"crossref","first-page":"1136","DOI":"10.1016\/j.jacc.2012.07.005","article-title":"Valve prosthesis-patient mismatch. 1978 to 2011: From original concept to compelling evidence","volume":"60","author":"Pibarot","year":"2012","journal-title":"J Am Coll Cardiol"}],"container-title":["Journal of Cardiac Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fjocs.12265","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fjocs.12265","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/onlinelibrary.wiley.com\/wol1\/doi\/10.1111\/jocs.12265\/fullpdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,6]],"date-time":"2023-01-06T11:50:49Z","timestamp":1673005849000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jocs.12265"}},"subtitle":["MISMATCH PREDICTS CARDIAC EVENTS"],"short-title":[],"issued":{"date-parts":[[2013,12,12]]},"references-count":24,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2014,3]]}},"URL":"https:\/\/doi.org\/10.1111\/jocs.12265","archive":["Portico"],"relation":{},"ISSN":["0886-0440"],"issn-type":[{"value":"0886-0440","type":"print"}],"subject":[],"published":{"date-parts":[[2013,12,12]]}}}