{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T06:28:39Z","timestamp":1791440919762,"version":"4.3.3"},"reference-count":22,"publisher":"Wiley","issue":"8","license":[{"start":{"date-parts":[[2024,6,24]],"date-time":"2024-06-24T00:00:00Z","timestamp":1719187200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["obgyn.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J of Obstet and Gynaecol"],"published-print":{"date-parts":[[2024,8]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Aim<\/jats:title><jats:p>The aim of this study is to investigate whether the results of pelvimetry using original radiographic Martius images and the same images with high\u2010pass filtering applied (\u201cedge images\u201d) would be consistent.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>A total of 30 primagravidas were included in this study. Three obstetricians independently measured the anteroposterior and transverse diameters of the pelvic inlet in the original and the edge images, recording the x\u2010 and y\u2010coordinates of the four endpoints. A Wilcoxon signed rank sum test was performed on the coordinate data to evaluate differences between the original and edge images.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>In the analysis of all coordinate data, statistically significant differences were found in both x\u2010 and y\u2010coordinates of the sacral promontory point (SPP). In the y\u2010coordinate of the SPP, a statistically significant difference was found in 9 of 30 pairs of images, and in all 9 the anteroposterior diameter was shorter in the edge images compared to the original images due to the more caudal placement of the SPP.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>The coordinates of the SPP on original radiographs and their edge images were not consistent in pelvimetry using Martius images. Our results suggest that improved image contrast will allow obstetricians to better assess pelvic narrowing and cephalopelvic disproportion and even reduce radiographic dose, thereby reducing risks for pregnant women and their fetuses.<\/jats:p><\/jats:sec>","DOI":"10.1111\/jog.16006","type":"journal-article","created":{"date-parts":[[2024,6,24]],"date-time":"2024-06-24T23:59:32Z","timestamp":1719273572000},"page":"1309-1316","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Effects of applying high\u2010pass filtering in pelvimetry with Martius images"],"prefix":"10.1111","volume":"50","author":[{"ORCID":"https:\/\/orcid.org\/0009-0006-9435-4919","authenticated-orcid":false,"given":"Nobuaki","family":"Suzuki","sequence":"first","affiliation":[{"name":"Department of Radiology NTT East Medical Center Sapporo  Sapporo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seiji","family":"Kumazawa","sequence":"additional","affiliation":[{"name":"Department of Radiological Sciences, Faculty of Health Sciences Hokkaido University of Science  Sapporo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-4565-0918","authenticated-orcid":false,"given":"Yohei","family":"Ono","sequence":"additional","affiliation":[{"name":"Department of Radiology NTT East Medical Center Sapporo  Sapporo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2024,6,24]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1002\/ar.24880"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajog.2013.02.050"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11547-009-0390-x"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1080\/14767058.2023.2190444"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.179.1.1790137"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1177\/2058460119855187"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eurox.2023.100216"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.diii.2018.02.008"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.diii.2014.01.021"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.31083\/j.ceog.2021.02.2336"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiographics.11.2.2028065"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0000000000000646"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1097\/00005382-200307000-00004"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2007.04.017"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4718571"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.3348\/kjr.2018.19.3.526"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.1177\/02841851221087631"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1038\/nmeth.2089"},{"issue":"7","key":"e_1_2_9_20_1","first-page":"36","article-title":"Image processing with ImageJ","volume":"11","author":"Abramoff MD","year":"2004","journal-title":"Biophotonics Int"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.1038\/bmt.2012.244"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcm.2016.02.012"},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1759-7714.2011.00045.x"}],"container-title":["Journal of Obstetrics and Gynaecology Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/obgyn.onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jog.16006","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,2]],"date-time":"2024-08-02T00:03:12Z","timestamp":1722556992000},"score":1,"resource":{"primary":{"URL":"https:\/\/obgyn.onlinelibrary.wiley.com\/doi\/10.1111\/jog.16006"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,24]]},"references-count":22,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2024,8]]}},"alternative-id":["10.1111\/jog.16006"],"URL":"https:\/\/doi.org\/10.1111\/jog.16006","archive":["Portico"],"relation":{},"ISSN":["1341-8076","1447-0756"],"issn-type":[{"value":"1341-8076","type":"print"},{"value":"1447-0756","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,6,24]]},"assertion":[{"value":"2024-02-28","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-06-10","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-06-24","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}