{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T22:31:42Z","timestamp":1761863502622},"reference-count":21,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2015,10,21]],"date-time":"2015-10-21T00:00:00Z","timestamp":1445385600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Interven Cardiology"],"published-print":{"date-parts":[[2015,12]]},"abstract":"<jats:sec><jats:title>Objectives<\/jats:title><jats:p>To compare early outcomes between Direct Flow Medical (DFM) and 1<jats:sup>st<\/jats:sup>\u2010generation transcatheter aortic valve replacement (TAVR) devices.<\/jats:p><\/jats:sec><jats:sec><jats:title>Background<\/jats:title><jats:p>The effectiveness of new\u2010generation TAVR devices compared with earlier generations is unclear.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods and Results<\/jats:title><jats:p>Overall, 496 patients treated between November 2007 and March 2014 were included: 44 (8.7%) treated with DFM, 179 (36.9%) with Medtronic CoreValve (MCV) and 273 (54.4%) with Edwards Sapien \/ Sapien XT (SXT) valve. Because of differences in baseline characteristics, propensity\u2010score matching among patients treated in the same time span (March 2012\u2013March 2014) was performed. The primary objective was the VARC\u20102 device success composite endpoint. Propensity\u2010score matching identified 41 patients in each group. A higher device success composite endpoint was observed in DFM (DFM 97.6% vs. MCV 65.9% vs. SXT 92.7%; P\u2009&lt;\u20090.001). This was attributed to a significantly lower incidence of moderate\u2010to\u2010severe post\u2010procedural aortic regurgitation (AR; 2.4% vs. 22% vs. 7.3%; P\u2009&lt;\u20090.001), lower rate of valve embolization (0% vs. 7.3% vs. 0%; 0.041) and need for a 2nd valve implantation (0% vs. 7.3% vs. 0%; P\u2009=\u20090.041).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>DFM was associated with higher rates of device success and a lower incidence of post\u2010procedural AR. New generation devices appear to address several of the limitations of earlier generation devices. (J Interven\nCardiol 2015;28:583\u2013593)<\/jats:p><\/jats:sec>","DOI":"10.1111\/joic.12248","type":"journal-article","created":{"date-parts":[[2015,10,21]],"date-time":"2015-10-21T05:52:42Z","timestamp":1445406762000},"page":"583-593","source":"Crossref","is-referenced-by-count":8,"title":["Early Outcomes With Direct Flow Medical Versus First\u2010Generation Transcatheter Aortic Valve Devices: A Single\u2010Center Propensity\u2010Matched Analysis"],"prefix":"10.1111","volume":"28","author":[{"given":"Gennaro","family":"Giustino","sequence":"first","affiliation":[{"name":"Interventional Cardiology Unit and Cardiothoracic Department San Raffaele Scientific Institute Milan Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Azeem","family":"Latib","sequence":"additional","affiliation":[{"name":"Interventional Cardiology Unit EMO\u2010GVM Centro Cuore Columbus Milan Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vasileios F.","family":"Panoulas","sequence":"additional","affiliation":[{"name":"Imperial College London National Heart and Lung Institute London UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matteo","family":"Montorfano","sequence":"additional","affiliation":[{"name":"Interventional Cardiology Unit and Cardiothoracic Department San Raffaele Scientific Institute Milan Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alaide","family":"Chieffo","sequence":"additional","affiliation":[{"name":"Interventional Cardiology Unit and Cardiothoracic Department San Raffaele Scientific Institute Milan Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maurizio","family":"Taramasso","sequence":"additional","affiliation":[{"name":"Interventional Cardiology Unit and Cardiothoracic Department San Raffaele Scientific Institute Milan Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katsumasa","family":"Sato","sequence":"additional","affiliation":[{"name":"Interventional Cardiology Unit and Cardiothoracic Department San Raffaele Scientific Institute Milan Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eustachio","family":"Agricola","sequence":"additional","affiliation":[{"name":"Interventional Cardiology Unit and Cardiothoracic Department San Raffaele Scientific Institute Milan Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ottavio","family":"Alfieri","sequence":"additional","affiliation":[{"name":"Interventional Cardiology Unit and Cardiothoracic Department San Raffaele Scientific Institute Milan Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Antonio","family":"Colombo","sequence":"additional","affiliation":[{"name":"Interventional Cardiology Unit and Cardiothoracic Department San Raffaele Scientific Institute Milan Italy"},{"name":"Interventional Cardiology Unit EMO\u2010GVM Centro Cuore Columbus Milan Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2015,10,21]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2014.02.536"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2013.10.013"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.4244\/EIJV4I2A45"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1200384"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(64)90027-X"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.111.961128"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2012.09.001"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1097\/EDE.0b013e318289dedf"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1103510"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1400590"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2013.01.047"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2014.3316"},{"key":"e_1_2_7_14_1","unstructured":"KodaliS.Early clinical and echocardiographic outcomes with the Sapien 3 transcatheter aortic valve replacement system in inoperable high\u2010risk and intermediate\u2010risk aortic stenosis patients. Presented at: American College of Cardiology\/i2 Scientific Session;. March 15 2015; San Diego CA."},{"key":"e_1_2_7_15_1","doi-asserted-by":"crossref","unstructured":"MeredithI. Early Results from the CoreValve Evolut R CE Study. Presented at the Annual Meeting of the American College of Cardiology March 14 2015.","DOI":"10.1016\/S0735-1097(15)61782-X"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2014.02.556"},{"key":"e_1_2_7_17_1","unstructured":"LinkeA.The ADVANCE TAVR registry. Presented at TCT 2012; October 22 2012; Miami FL."},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.112.001099"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2012.03.054"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2012.07.003"},{"key":"e_1_2_7_21_1","unstructured":"LeonMB.A Randomized Evaluation of the SAPIEN XT Transcatheter Valve System in Patients with Aortic Stenosis Who Are Not Candidates for Surgery: PARTNER II Inoperable Cohort. Presented at: American College of Cardiology Annual Scientific Session; March 10 2013; San Francisco CA."},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cjca.2015.05.006"}],"container-title":["Journal of Interventional Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fjoic.12248","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fjoic.12248","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/joic.12248","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,4]],"date-time":"2023-10-04T22:57:23Z","timestamp":1696460243000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/joic.12248"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,10,21]]},"references-count":21,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2015,12]]}},"alternative-id":["10.1111\/joic.12248"],"URL":"https:\/\/doi.org\/10.1111\/joic.12248","archive":["Portico"],"relation":{},"ISSN":["0896-4327","1540-8183"],"issn-type":[{"value":"0896-4327","type":"print"},{"value":"1540-8183","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,10,21]]}}}