{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T16:35:08Z","timestamp":1773246908235,"version":"3.50.1"},"reference-count":10,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2018,10,28]],"date-time":"2018-10-28T00:00:00Z","timestamp":1540684800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Interven Cardiology"],"published-print":{"date-parts":[[2018,12]]},"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>Percutaneous stent implantation in the coronary artery is a potential bailout option after coronary compression during Transcatheter pulmonary valve replacement, but the structural integrity of the coronary stent in this environment is uncertain.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>An invitro model was constructed to represent the interaction between coronary and outflow tract stents. One AndraStent, four CP stents, one Edwards SAPIEN XT valve stent and combination of AndraStent with CP stent were incrementally compressed against a coronary stent. The stent diameters were measured with a code developed in MATLAB. The relative decrease in diameter was calculated for each stent over a range of compression.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>In all combinations of stents, coronary stent lost significantly more relative diameter when compared with larger outflow tract stents. At maximum compressive amplitude, average percent decrease in diameters of AndraStent(r) versus coronary stent: 8.1\u2009\u00b1\u20090.8% and 36.5\u2009\u00b1\u200911.1% respectively. CP stent\u2122 versus coronary stent, the decrease was 5.7\u2009\u00b1\u20090.8% and 45.2\u2009\u00b1\u20099.2% respectively. Combined CP stent\u2122 mounted within the AndraStent(r), versus coronary stent: 3.9\u2009\u00b1\u20090.5% and 54.5\u2009\u00b1\u20094.2% respectively. Edwards Sapien stent versus the coronary stent: 1.7\u2009\u00b1\u20090.1% and 68.9\u2009\u00b1\u20091.1% respectively.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The relative deformation of the coronary stent was significantly higher than deformation of the other stents. Edwards Sapien XT valve stent has greater relative radial force demonstrated by the greater relative decrease in diameter of the coronary stent at final compressive amplitude. These results support the concern that coronary stenting in the presence of coronary compression by an outflow tract stent implantation is likely to result in a significantly compromised coronary lumen.<\/jats:p><\/jats:sec>","DOI":"10.1111\/joic.12565","type":"journal-article","created":{"date-parts":[[2018,10,29]],"date-time":"2018-10-29T00:49:28Z","timestamp":1540774168000},"page":"870-877","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Using in vitro model to assess stent\u2010stent interaction in patients with coronary artery compression"],"prefix":"10.1111","volume":"31","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9146-8551","authenticated-orcid":false,"given":"Jenny E.","family":"Zablah","sequence":"first","affiliation":[{"name":"The Heart Institute, Children's Hospital of Colorado University of Colorado Aurora Colorado"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rachel","family":"Fry","sequence":"additional","affiliation":[{"name":"The Heart Institute, Children's Hospital of Colorado University of Colorado Aurora Colorado"},{"name":"Department of Biomedical Engineering University of Colorado Aurora Colorado"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Ross","sequence":"additional","affiliation":[{"name":"The Heart Institute, Children's Hospital of Colorado University of Colorado Aurora Colorado"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Neil","family":"Wilson","sequence":"additional","affiliation":[{"name":"The Heart Institute, Children's Hospital of Colorado University of Colorado Aurora Colorado"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gareth","family":"Morgan","sequence":"additional","affiliation":[{"name":"The Heart Institute, Children's Hospital of Colorado University of Colorado Aurora Colorado"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2018,10,28]]},"reference":[{"key":"e_1_2_7_2_1","first-page":"959704","article-title":"Left main Coronary artery compression following melody pulmonary valve implantation: use of impella support as rescue therapy and perioperative challenges with ECMO","volume":"2014","author":"Wittwer ED","year":"2014","journal-title":"Case Rep Crit Care"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.25471"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1017\/S1047951112001187"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.113.000202"},{"key":"e_1_2_7_6_1","unstructured":"HornyL. et al. In vitro Coronary Stent Implantation: Vessel Wall\u2010Stent Interaction. In: Jobb\u00e1gy \u00c1. (eds) 5th European Conference of the International Federation for Medical and Biological Engineering. IFMBE Proceedings vol 37. Springer Berlin Heidelberg. ISBN 978\u20103\u2010642\u201023507\u20108."},{"key":"e_1_2_7_7_1","first-page":"294","article-title":"A new strategy to identify potentially dangerous coronary arterial patterns before percutaneous pulmonary valve implantation","volume":"10","author":"G\u00f3reczny S","year":"2014","journal-title":"Postepy Kardiol Interwencyjnej"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00246-017-1574-0"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.7150\/thno.8137"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.21769"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.21928"}],"container-title":["Journal of Interventional Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fjoic.12565","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/joic.12565","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,15]],"date-time":"2023-09-15T06:44:47Z","timestamp":1694760287000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/joic.12565"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,10,28]]},"references-count":10,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2018,12]]}},"alternative-id":["10.1111\/joic.12565"],"URL":"https:\/\/doi.org\/10.1111\/joic.12565","archive":["Portico"],"relation":{},"ISSN":["0896-4327","1540-8183"],"issn-type":[{"value":"0896-4327","type":"print"},{"value":"1540-8183","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,10,28]]},"assertion":[{"value":"2018-06-07","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-10-07","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-10-28","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}