{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,13]],"date-time":"2026-01-13T16:51:53Z","timestamp":1768323113748,"version":"3.49.0"},"reference-count":26,"publisher":"Wiley","issue":"12","license":[{"start":{"date-parts":[[2013,11,7]],"date-time":"2013-11-07T00:00:00Z","timestamp":1383782400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J of Oral Rehabilitation"],"published-print":{"date-parts":[[2013,12]]},"abstract":"<jats:title>Summary<\/jats:title><jats:p>To treat sleep bruxism (<jats:styled-content style=\"fixed-case\">SB<\/jats:styled-content>), symptomatic therapy using stabilisation splints (<jats:styled-content style=\"fixed-case\">SS<\/jats:styled-content>) is frequently used. However, their effects on psychological stress and sleep quality have not yet been examined fully. The objective of this study was to clarify the effects of <jats:styled-content style=\"fixed-case\">SS<\/jats:styled-content> use on psychological stress and sleep quality. The subjects (11 men, 12 women) were healthy volunteers. A crossover design was used. Sleep measurements were performed for three consecutive days or longer without (baseline) or with an <jats:styled-content style=\"fixed-case\">SS<\/jats:styled-content> or palatal splint (<jats:styled-content style=\"fixed-case\">PS<\/jats:styled-content>), and data for the final day were evaluated. We measured masseter muscle activity during sleep using portable electromyography to evaluate <jats:styled-content style=\"fixed-case\">SB<\/jats:styled-content>. Furthermore, to compare psychological stress before and after sleep, assessments were made based on <jats:styled-content style=\"fixed-case\">STAI<\/jats:styled-content>\u2010<jats:styled-content style=\"fixed-case\">JYZ<\/jats:styled-content> and the measurement of salivary chromogranin A. To compare each parameter among the three groups (baseline, <jats:styled-content style=\"fixed-case\">SS<\/jats:styled-content> and <jats:styled-content style=\"fixed-case\">PS<\/jats:styled-content>), Friedman's and Dunn's tests were used. From the results of the baseline measurements, eight subjects were identified as high group and 15 as low group. Among the high group, a marked decrease in the number of bruxism events per hour and an increase in the difference in the total <jats:styled-content style=\"fixed-case\">STAI<\/jats:styled-content> Y\u20101 scores were observed in the <jats:styled-content style=\"fixed-case\">SS<\/jats:styled-content> group compared with those at baseline (<jats:italic>P<\/jats:italic>\u00a0&lt;\u00a00\u00b705). No significant difference was observed in sleep stages. <jats:styled-content style=\"fixed-case\">SS<\/jats:styled-content> use may be effective in reducing the number of <jats:styled-content style=\"fixed-case\">SB<\/jats:styled-content> events, while it may increase psychological stress levels, and <jats:styled-content style=\"fixed-case\">SS<\/jats:styled-content> use did not apparently influence sleep stages.<\/jats:p>","DOI":"10.1111\/joor.12110","type":"journal-article","created":{"date-parts":[[2013,11,7]],"date-time":"2013-11-07T07:22:44Z","timestamp":1383808964000},"page":"892-899","source":"Crossref","is-referenced-by-count":36,"title":["Management of sleep\u2010time masticatory muscle activity using stabilisation splints affects psychological stress"],"prefix":"10.1111","volume":"40","author":[{"given":"H.","family":"Takahashi","sequence":"first","affiliation":[{"name":"Department of Oral Reconstruction and Rehabilitation Kyushu Dental University Fukuoka Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.","family":"Masaki","sequence":"additional","affiliation":[{"name":"Department of Oral Reconstruction and Rehabilitation Kyushu Dental University Fukuoka Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Makino","sequence":"additional","affiliation":[{"name":"Department of Oral Geriatric Dentistry Fukuoka Dental College Fukuoka Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Yoshida","sequence":"additional","affiliation":[{"name":"SleepWell Co., Ltd Osaka Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T.","family":"Mukaibo","sequence":"additional","affiliation":[{"name":"Department of Oral Reconstruction and Rehabilitation Kyushu Dental University Fukuoka Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Y.","family":"Kondo","sequence":"additional","affiliation":[{"name":"Department of Oral Reconstruction and Rehabilitation Kyushu Dental University Fukuoka Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T.","family":"Nakamoto","sequence":"additional","affiliation":[{"name":"Department of Oral Reconstruction and Rehabilitation Kyushu Dental University Fukuoka Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R.","family":"Hosokawa","sequence":"additional","affiliation":[{"name":"Department of Oral Reconstruction and Rehabilitation Kyushu Dental University Fukuoka Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2013,11,7]]},"reference":[{"key":"e_1_2_7_2_1","volume-title":"The international classification of sleep disorders. 2nd edition: diagnostic and coding manual","author":"AASM","year":"2005"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/joor.12011"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpor.2008.08.003"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1902\/jop.1996.67.7.666"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1067\/mpr.2001.116578"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0501.2001.120505.x"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0501.2001.012001026.x"},{"key":"e_1_2_7_9_1","first-page":"153","article-title":"Role of psychosocial factors in the etiology of bruxism","volume":"23","author":"Manfredini D","year":"2009","journal-title":"J Orofac Pain"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10354-004-0129-1"},{"key":"e_1_2_7_11_1","first-page":"43","article-title":"The relationship between sleep bruxism behavior and salivary stress biomarker level","volume":"22","author":"Makino M","year":"2009","journal-title":"Int J Prosthodont"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1093\/sleep\/20.11.982"},{"key":"e_1_2_7_13_1","first-page":"191","article-title":"Topical review: sleep bruxism and the role of peripheral sensory influences","volume":"17","author":"Kato T","year":"2003","journal-title":"J Orofac Pain"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12548-011-0004-9"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1177\/154405910408300509"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2842.2005.01576.x"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1159\/000085917"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1093\/sleep\/29.3.307"},{"key":"e_1_2_7_19_1","first-page":"435","article-title":"Comparison of various treatments for sleep bruxism using determinants of number needed to treat and effect size","volume":"19","author":"Huynh NT","year":"2006","journal-title":"Int J Prosthodont"},{"key":"e_1_2_7_20_1","first-page":"151","article-title":"Controlled assessment of the efficacy of occlusal stabilization splints on sleep bruxism","volume":"19","author":"van der Zaag J","year":"2005","journal-title":"J Orofac Pain"},{"key":"e_1_2_7_21_1","first-page":"270","article-title":"Criteria for the detection of sleep\u2010associated bruxism in humans","volume":"10","author":"Ikeda T","year":"1996","journal-title":"J Orofac Pain"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1177\/00220345960750010601"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.2466\/pr0.1998.82.2.651"},{"key":"e_1_2_7_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.oooo.2011.10.008"},{"key":"e_1_2_7_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0167-8760(02)00067-3"},{"key":"e_1_2_7_26_1","doi-asserted-by":"publisher","DOI":"10.1080\/00223980309600624"},{"key":"e_1_2_7_27_1","first-page":"152","article-title":"Decreased amount of slow wave sleep in nocturnal bruxism is not improved by dental splint therapy","volume":"101","author":"Nagels G","year":"2001","journal-title":"Acta Neurol Belg"}],"container-title":["Journal of Oral Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fjoor.12110","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fjoor.12110","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/joor.12110","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,5]],"date-time":"2023-10-05T10:17:41Z","timestamp":1696501061000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/joor.12110"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,11,7]]},"references-count":26,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2013,12]]}},"alternative-id":["10.1111\/joor.12110"],"URL":"https:\/\/doi.org\/10.1111\/joor.12110","archive":["Portico"],"relation":{},"ISSN":["0305-182X","1365-2842"],"issn-type":[{"value":"0305-182X","type":"print"},{"value":"1365-2842","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,11,7]]}}}