{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T19:03:13Z","timestamp":1790362993562,"version":"4.1.0"},"reference-count":41,"publisher":"Wiley","issue":"12","license":[{"start":{"date-parts":[[2020,10,28]],"date-time":"2020-10-28T00:00:00Z","timestamp":1603843200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J of Oral Rehabilitation"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Summary<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To compare the manual time and preliminary clinical effects between the digital manufactured occlusal splints for sleep bruxism patients with those of traditional hard splints.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Sixteen individuals (18 to 44\u00a0y\/o) with clinically diagnosed sleep bruxism were selected based on the inclusion criteria. All patients were divided into two groups, and a random control method was applied. Digital splints (test group) were designed and milled using CAD\/CAM. Hard splints (control group) were made of transparent acrylic resin in laboratory office. The manual time spent including impression obtaining, splint production and clinical occlusal adjustment was recorded. A visual analog scale was used to report the subjective evaluations. The maximum depth loss and volumetric loss of the occlusal surface of splints in posterior tooth were measured. SPSS software was used for statistical analysis (\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0=\u00a0.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Comparing with control group, the manual time spent in test group was significantly less in all of three procedures (\n                      <jats:italic>P\u00a0&lt;\u00a0<\/jats:italic>\n                      .001). The VAS scores for retention were not significantly different (\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0=\u00a0.086), but the wearing comfort scores of test group were significantly higher (\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0&lt;\u00a0.001). Both maximum depth loss (\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0=\u00a0.007) and volumetric loss in test group were significantly less than control group (\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0=\u00a0.005).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>In the current study, the digitally manufactured splints exhibit significantly improved comfort and time efficiency than traditional hard splints. Moreover, the new milling material (PEEK) has better wear resistance than acrylic resins.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/joor.13083","type":"journal-article","created":{"date-parts":[[2020,8,26]],"date-time":"2020-08-26T03:43:53Z","timestamp":1598413433000},"page":"1530-1537","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":34,"title":["Preliminary clinical evaluation of traditional and a new digital PEEK occlusal splints for the management of sleep bruxism"],"prefix":"10.1111","volume":"47","author":[{"given":"Shimin","family":"Wang","sequence":"first","affiliation":[{"name":"Department of Prosthodontics Peking University School and Hospital of Stomatology  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zheng","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics Peking University School and Hospital of Stomatology  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hongqiang","family":"Ye","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics Peking University School and Hospital of Stomatology National Clinical Research Center for Oral Diseases National Engineering Laboratory for Digital and Material Technology of Stomatology Beijing Key Laboratory of Digital Stomatology  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenyan","family":"Zhao","sequence":"additional","affiliation":[{"name":"Department of Implantology Yinchuan Stomatology Hospital  Yinchuan China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8364-1898","authenticated-orcid":false,"given":"Yunsong","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics Peking University School and Hospital of Stomatology National Clinical Research Center for Oral Diseases National Engineering Laboratory for Digital and Material Technology of Stomatology Beijing Key Laboratory of Digital Stomatology  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4332-0878","authenticated-orcid":false,"given":"Yongsheng","family":"Zhou","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics Peking University School and Hospital of Stomatology National Clinical Research Center for Oral Diseases National Engineering Laboratory for Digital and Material Technology of Stomatology Beijing Key Laboratory of Digital Stomatology  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2020,10,28]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1111\/joor.12011"},{"issue":"5","key":"e_1_2_9_3_1","first-page":"286","article-title":"The effects of stabilization splint treatment on the volume of masseter muscle in sleep bruxism patients","volume":"36","author":"Tuna SH","year":"2018","journal-title":"Cranio"},{"issue":"1","key":"e_1_2_9_4_1","first-page":"45","article-title":"Occlusal splints and periodontal\/implant therapy","volume":"21","author":"Sutthiboonyapan P","year":"2019","journal-title":"J Int Acad Periodontol"},{"issue":"1","key":"e_1_2_9_5_1","first-page":"S265","article-title":"Bruxism: conceptual discussion and review","volume":"7","author":"Murali RV","year":"2015","journal-title":"J Pharm Bioallied Sci"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2842.2001.00839.x"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11940-016-0396-3"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1111\/joor.12426"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/joor.12413"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/joor.12663"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0300-5712(00)00026-9"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2842.2005.01576.x"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2015.02.025"},{"issue":"1","key":"e_1_2_9_14_1","first-page":"66","article-title":"Influence of occlusal stabilization splints and soft occlusal splints on the electromyographic pattern, in basal state and at the end of six weeks treatment in patients with bruxism","volume":"24","author":"Cruz\u2010Reyes RA","year":"2011","journal-title":"Acta Odontol Latinoam"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpor.2009.02.006"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.sdentj.2014.12.004"},{"issue":"3","key":"e_1_2_9_17_1","first-page":"181","article-title":"CAD\/CAM splints for the functional and esthetic evaluation of newly defined occlusal dimensions","volume":"48","author":"Edelhoff D","year":"2017","journal-title":"Quintessence Int"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajodo.2018.09.012"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1098\/rsif.2013.0203"},{"issue":"1","key":"e_1_2_9_20_1","first-page":"63","article-title":"Digital Michigan splint \u2010 from intraoral scanning to plasterless manufacturing","volume":"19","author":"Dedem P","year":"2016","journal-title":"Int J Comput Dent"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2842.2008.01881.x"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1177\/154405910408300509"},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2018.09.021"},{"key":"e_1_2_9_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpor.2015.10.001"},{"key":"e_1_2_9_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2017.04.017"},{"issue":"2","key":"e_1_2_9_26_1","doi-asserted-by":"crossref","first-page":"149","DOI":"10.11607\/ijp.5508","article-title":"A novel computer\u2010aided design\/computer\u2010assisted manufacture method for one\u2010piece removable partial denture and evaluation of fit","volume":"31","author":"Ye H","year":"2018","journal-title":"Int J Prosthodont"},{"key":"e_1_2_9_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2015.12.038"},{"key":"e_1_2_9_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2016.03.005"},{"key":"e_1_2_9_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2012.12.011"},{"key":"e_1_2_9_30_1","doi-asserted-by":"publisher","DOI":"10.1902\/jop.2001.72.8.1108"},{"key":"e_1_2_9_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(73)90267-9"},{"key":"e_1_2_9_32_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-849X.2012.00926.x"},{"key":"e_1_2_9_33_1","doi-asserted-by":"publisher","DOI":"10.3390\/ma12121958"},{"key":"e_1_2_9_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2019.02.008"},{"issue":"8","key":"e_1_2_9_35_1","doi-asserted-by":"crossref","first-page":"702","DOI":"10.1016\/j.dental.2006.02.003","article-title":"Intra\u2010oral restorative materials wear: rethinking the current approaches: how to measure wear","volume":"22","author":"DeLong R","year":"2006","journal-title":"Dent Mater"},{"key":"e_1_2_9_36_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(09)60118-9"},{"key":"e_1_2_9_37_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00784-011-0534-y"},{"key":"e_1_2_9_38_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpor.2016.12.007"},{"key":"e_1_2_9_39_1","doi-asserted-by":"publisher","DOI":"10.1177\/00220345970760111201"},{"key":"e_1_2_9_40_1","doi-asserted-by":"publisher","DOI":"10.1038\/ijos.2013.73"},{"key":"e_1_2_9_41_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2017.10.005"},{"key":"e_1_2_9_42_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdsr.2017.11.002"}],"container-title":["Journal of Oral Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/joor.13083","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/joor.13083","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/joor.13083","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,4]],"date-time":"2023-09-04T06:28:01Z","timestamp":1693808881000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/joor.13083"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,10,28]]},"references-count":41,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["10.1111\/joor.13083"],"URL":"https:\/\/doi.org\/10.1111\/joor.13083","archive":["Portico"],"relation":{"has-review":[{"id-type":"doi","id":"10.1111\/JOOR.13083\/v2\/response1","asserted-by":"object"},{"id-type":"doi","id":"10.1111\/JOOR.13083\/v2\/decision1","asserted-by":"object"},{"id-type":"doi","id":"10.1111\/JOOR.13083\/v3\/decision1","asserted-by":"object"},{"id-type":"doi","id":"10.1111\/JOOR.13083\/v1\/decision1","asserted-by":"object"},{"id-type":"doi","id":"10.1111\/JOOR.13083\/v3\/response1","asserted-by":"object"},{"id-type":"doi","id":"10.1111\/JOOR.13083\/v1\/review1","asserted-by":"object"},{"id-type":"doi","id":"10.1111\/JOOR.13083\/v2\/review1","asserted-by":"object"},{"id-type":"doi","id":"10.1111\/JOOR.13083\/v3\/review1","asserted-by":"object"}]},"ISSN":["0305-182X","1365-2842"],"issn-type":[{"value":"0305-182X","type":"print"},{"value":"1365-2842","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,10,28]]},"assertion":[{"value":"2020-02-01","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-08-11","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-10-28","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}