{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T04:23:52Z","timestamp":1788495832496,"version":"build-2803163510"},"reference-count":22,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2015,11,30]],"date-time":"2015-11-30T00:00:00Z","timestamp":1448841600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Prosthodontics"],"published-print":{"date-parts":[[2017,4]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Purpose<\/jats:title><jats:p>To evaluate the wear resistance of nano\u2010hybrid composite denture teeth as compared to two commonly used denture teeth: interpenetrating polymer network (IPN) and double crosslinking polymethylmethacrylate (PMMA) denture teeth.<\/jats:p><\/jats:sec><jats:sec><jats:title>Material and Methods<\/jats:title><jats:p>18 styli and 18 disk specimens were prepared from the three denture tooth materials: nano\u2010hybrid composite, IPN, and double crosslinking PMMA. The specimens were mounted in a two\u2010body wear testing machine to simulate chewing in the complete denture. The amount of wear from the styli specimens were measured before and after using a digital micrometer, and the depth of the wear track from the disk specimens was measured using a noncontact 3D optical profilometer. The total wear from each denture tooth group was compared using one\u2010way ANOVA with a 0.05 significance level. A Tukey post hoc test was used to determine differences between the three groups.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The mean total wear in the nano\u2010hybrid composite teeth group was 1.16 mm, SD = 0.5 mm, statistically significantly higher (<jats:italic>p<\/jats:italic> \u2264 0.0001) than the IPN (mean = 0.13 mm, SD = 0.05) and double crosslinking PMMA tooth groups (mean = 0.31 mm, SD = 0.19). There was no statistically significant difference between IPN denture teeth and double crosslinking PMMA denture teeth in the amount of wear.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>Nano\u2010hybrid composite denture teeth exhibited statistically significantly more wear than the IPN and double crosslinking PMMA denture teeth.<\/jats:p><\/jats:sec>","DOI":"10.1111\/jopr.12412","type":"journal-article","created":{"date-parts":[[2015,11,30]],"date-time":"2015-11-30T14:50:41Z","timestamp":1448895041000},"page":"224-229","source":"Crossref","is-referenced-by-count":35,"title":["In Vitro Wear Resistance of Nano\u2010Hybrid Composite Denture Teeth"],"prefix":"10.1111","volume":"26","author":[{"given":"Nabeel","family":"Munshi","sequence":"first","affiliation":[{"name":"Department of Oral and Maxillofacial Rehabilitation Faculty of Dentistry, King Abdulaziz University  Jeddah Saudi Arabia"},{"name":"Prosthodontics postgraduate program Rutgers University School of Dental Medicine  Newark NJ"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marc","family":"Rosenblum","sequence":"additional","affiliation":[{"name":"Department of Restorative Dentistry, Director of the General Dentistry Division Rutgers University School of Dental Medicine  Newark NJ"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuying","family":"Jiang","sequence":"additional","affiliation":[{"name":"Institutional Assessment and Quality Improvement Rutgers University School of Dental Medicine  Newark NJ"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Flinton","sequence":"additional","affiliation":[{"name":"Department of Restorative Dentistry Rutgers University School of Dental Medicine  Newark NJ"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2015,11,30]]},"reference":[{"key":"e_1_2_6_2_1","first-page":"331","volume-title":"Dental Materials and Their Selection","author":"O'Brien W","year":"1997"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-849X.2004.04043.x"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1155\/2014\/746252"},{"key":"e_1_2_6_5_1","first-page":"282","article-title":"Shock\u2010absorbing behavior of five materials for materials used on implants","volume":"4","author":"Gracis SE","year":"1991","journal-title":"Int J Prosthodont"},{"key":"e_1_2_6_6_1","first-page":"243","article-title":"Shock absorbability and hardness of commercially available denture teeth","volume":"15","author":"Kawano F","year":"2001","journal-title":"Int J Prosthodont"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.3109\/00016358909004808"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(85)80073-1"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(85)90304-X"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(88)90011-X"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2842.2001.00670.x"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(92)90590-7"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820240811"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820241208"},{"key":"e_1_2_6_15_1","first-page":"351","article-title":"Characterization of hard resin teeth with nanocomposite enamel layer","volume":"21","author":"Teraoka F","year":"2002","journal-title":"J Jpn Soc Dent Mater Dev"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2007.04.012"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1590\/S1678-77572008000300003"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(09)60051-2"},{"key":"e_1_2_6_19_1","unstructured":"HahnelS BehrendD OttlP et al: Two\u2010body wear of denture resin teeth. IADR Barcelona 2010. # 1456. Available online athttps:\/\/iadr.confex.com\/iadr\/2010barce\/webprogram\/Paper138125.html. Accessed July 10 2015"},{"key":"e_1_2_6_20_1","unstructured":"LattaM ShanerJ: Localized wear of denture tooth materials. IADR Barcelona 2010. # 4068. Available online athttps:\/\/iadr.confex.com\/iadr\/2010barce\/webprogram\/Paper140085.html. Accessed July 10 2015"},{"key":"e_1_2_6_21_1","first-page":"504","article-title":"Occlusal contacts of edentulous patients with mandibular hybrid dentures opposing maxillary complete dentures","volume":"14","author":"Suzuki T","year":"1999","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2842.1979.tb00403.x"},{"key":"e_1_2_6_23_1","doi-asserted-by":"publisher","DOI":"10.1109\/10.133228"}],"container-title":["Journal of Prosthodontics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fjopr.12412","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fjopr.12412","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jopr.12412","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,2]],"date-time":"2023-10-02T18:32:59Z","timestamp":1696271579000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jopr.12412"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,11,30]]},"references-count":22,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2017,4]]}},"alternative-id":["10.1111\/jopr.12412"],"URL":"https:\/\/doi.org\/10.1111\/jopr.12412","archive":["Portico"],"relation":{},"ISSN":["1059-941X","1532-849X"],"issn-type":[{"value":"1059-941X","type":"print"},{"value":"1532-849X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,11,30]]}}}