{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,21]],"date-time":"2025-09-21T18:13:04Z","timestamp":1758478384228},"reference-count":32,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2017,9,2]],"date-time":"2017-09-02T00:00:00Z","timestamp":1504310400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Prosthodontics"],"published-print":{"date-parts":[[2017,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Telescopic crown attachments have been successfully used in completely and partially edentulous patients. This type of attachment provides retention, support, and stability with optimal hygiene for the removable dental prosthesis (RDP). With the emergence of CAD\/CAM technology, telescopic crown attachments can be virtually designed and milled precisely to ensure a passive fit of the attachment parts and maximal functionality of the RDP. This article reviews both the clinical outcome and prosthodontic rehabilitation of telescopic crown attachments of an edentulous ectodermal dysplasia patient with solitary rigid conical telescopic crown attachments.<\/jats:p>","DOI":"10.1111\/jopr.12657","type":"journal-article","created":{"date-parts":[[2017,9,2]],"date-time":"2017-09-02T12:08:37Z","timestamp":1504354117000},"page":"622-627","source":"Crossref","is-referenced-by-count":7,"title":["Prosthodontic Rehabilitation of an Ectodermal Dysplasia Patient with Implant Telescopic Crown Attachments"],"prefix":"10.1111","volume":"26","author":[{"given":"Hussain D.","family":"Alsayed","sequence":"first","affiliation":[{"name":"Department of Prosthodontics Indiana University School of Dentistry  Indianapolis IN"},{"name":"Department of Prosthetic Dental Science King Saud University  Riyadh Saudi Arabia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nasser M.","family":"Alqahtani","sequence":"additional","affiliation":[{"name":"Department of Prosthetic Dental Science King Khalid University  Abha Saudi Arabia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John A.","family":"Levon","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics Indiana University School of Dentistry  Indianapolis IN"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dean","family":"Morton","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics Indiana University School of Dentistry  Indianapolis IN"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2017,9,2]]},"reference":[{"key":"e_1_2_5_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(80)90070-0"},{"key":"e_1_2_5_3_1","doi-asserted-by":"publisher","DOI":"10.1067\/mpr.2000.108026"},{"key":"e_1_2_5_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2005.03.013"},{"key":"e_1_2_5_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(69)90211-X"},{"key":"e_1_2_5_6_1","first-page":"109","article-title":"Survival rates of teeth, implants, and double crown\u2010retained removable dental prostheses: a systematic literature review","volume":"24","author":"Koller B","year":"2011","journal-title":"Int J Prosthodont"},{"key":"e_1_2_5_7_1","first-page":"677","article-title":"The comparison of initial retentive force in different double crown systems","volume":"44","author":"Kwon HB","year":"2006","journal-title":"J Korean Acad Prosthodont"},{"key":"e_1_2_5_8_1","first-page":"927","article-title":"Telescopic crown\u2010retained removable partial dentures: review and case report","volume":"22","author":"Beschnidt SM","year":"2001","journal-title":"Compend Contin Educ Dent"},{"key":"e_1_2_5_9_1","first-page":"619","article-title":"Cone crowns\u2013a physically defined telescopic system","volume":"23","author":"Korber KH","year":"1968","journal-title":"Dtsch Zahnarztl Z"},{"key":"e_1_2_5_10_1","doi-asserted-by":"publisher","DOI":"10.1067\/mpr.2000.108026"},{"key":"e_1_2_5_11_1","first-page":"66","article-title":"CAD\/CAM and telescopic technology: design options for implant\u2010supported overdentures","volume":"3","author":"Bergler M","year":"2008","journal-title":"Eur J Esthet Dent"},{"key":"e_1_2_5_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(78)90005-7"},{"key":"e_1_2_5_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2014.01.028"},{"key":"e_1_2_5_14_1","doi-asserted-by":"publisher","DOI":"10.1067\/mpr.2002.127099"},{"key":"e_1_2_5_15_1","doi-asserted-by":"publisher","DOI":"10.1563\/AAID-JOI-D-12-00072"},{"key":"e_1_2_5_16_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1754-4505.2011.00222.x"},{"key":"e_1_2_5_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijom.2016.03.011"},{"key":"e_1_2_5_18_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-849X.1999.tb00005.x"},{"key":"e_1_2_5_19_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-849X.2012.00905.x"},{"key":"e_1_2_5_20_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1741-2358.2011.00524.x"},{"key":"e_1_2_5_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(94)90073-6"},{"key":"e_1_2_5_22_1","first-page":"401","article-title":"Prosthetic aspects and patient satisfaction with two\u2010implant\u2010retained mandibular overdentures: a 10\u2010year randomized clinical study","volume":"17","author":"Naert I","year":"2004","journal-title":"Int J Prosthodont"},{"key":"e_1_2_5_23_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2004.01064.x"},{"key":"e_1_2_5_24_1","doi-asserted-by":"publisher","DOI":"10.1067\/mpr.2001.118365"},{"key":"e_1_2_5_25_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-849X.2005.00005.x"},{"key":"e_1_2_5_26_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.12595"},{"key":"e_1_2_5_27_1","first-page":"398","article-title":"Patient\u2010reported outcome and its association with attachment type and bone volume in mandibular implant overdenture","volume":"44","author":"Khalid T","year":"2017","journal-title":"Clin Oral Implants Res"},{"key":"e_1_2_5_28_1","first-page":"598","article-title":"Comparison of ball and telescopic crown attachments in implant\u2010retained mandibular overdentures: a 5\u2010year prospective study","volume":"26","author":"Krennmair G","year":"2011","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_5_29_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2011.02169.x"},{"key":"e_1_2_5_30_1","first-page":"52","article-title":"Restoration of the maxillary arch using implants, natural teeth and the Konus crown: a case study","volume":"21","author":"Sethi A","year":"1994","journal-title":"Dent Update"},{"key":"e_1_2_5_31_1","first-page":"5","article-title":"Immediate implant\u2010supported mandibular overdentures retained by conical crowns: a new treatment concept","volume":"33","author":"May D","year":"2002","journal-title":"Quintessence Int"},{"key":"e_1_2_5_32_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2011.02225.x"},{"key":"e_1_2_5_33_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2007.01500.x"}],"container-title":["Journal of Prosthodontics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fjopr.12657","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jopr.12657","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,29]],"date-time":"2023-09-29T10:46:48Z","timestamp":1695984408000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jopr.12657"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,9,2]]},"references-count":32,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2017,10]]}},"alternative-id":["10.1111\/jopr.12657"],"URL":"https:\/\/doi.org\/10.1111\/jopr.12657","archive":["Portico"],"relation":{},"ISSN":["1059-941X","1532-849X"],"issn-type":[{"value":"1059-941X","type":"print"},{"value":"1532-849X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,9,2]]}}}