{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,4]],"date-time":"2026-07-04T07:10:48Z","timestamp":1783149048730,"version":"3.54.6"},"reference-count":24,"publisher":"Wiley","issue":"8","license":[{"start":{"date-parts":[[2024,7,25]],"date-time":"2024-07-25T00:00:00Z","timestamp":1721865600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Journal of Prosthodontics"],"published-print":{"date-parts":[[2025,10]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To determine the number of torque\/reverse torque cycles attachment screws can withstand before fracture, and to record the magnitude of reverse torque values for each of the 10 cycles of screw tightening and loosening.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods<\/jats:title>\n                    <jats:p>\n                      The testing assemblies consisted of 30 temporary cylinder\/multiunit abutment\/internal connection implants (10 each from Dentsply Sirona Astra, Biohorizons, and Zimmer Biomet Dental). The assemblies were inserted into resin blocks, and temporary cylinders were connected to the multiunit abutments with new attachment screws and torqued to the recommended preload (15 Ncm Dentsply Sirona Astra; 15 Ncm Biohorizons; 10 Ncm Zimmer Biomet Dental) using a digital\u00a0torque\u00a0gauge\u00a0instrument (Model 3, MARK\u201010 Corporation, New York, USA) at room temperature without lubrication. After 24 h, the attachment screws were reverse torqued with the same instrument and the values were recorded. The torque\/reverse torque cycles were repeated every 24 h for 10 days. Data were analyzed using mixed model analysis. A second test included torquing the used screws (30) until fracture or stripping occurred. The reverse torque values were recorded and compared with new screws that were torqued until fracture or stripping. A sample of used and new attachment screws from each assembly were viewed under both laser microscope (LEXT OLS4000, 3D Measuring Laser Microscope, Olympus) and scanning electron microscope (JEOL\u2010JSM6510, Tokyo, Japan). Data were analyzed using\n                      <jats:italic>t<\/jats:italic>\n                      \u2010test.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Following 10 cycles of torquing and reverse torquing, the reverse torque values measured on day 10 were lesser compared with the reverse torque value measured on day 1 for 29\/30 attachment screws (96.6%). According to the\n                      <jats:italic>t<\/jats:italic>\n                      \u2010test used for the second test, the\n                      <jats:italic>p<\/jats:italic>\n                      \u2010values among all three groups were \u22650.9 which were not statistically significant.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The results of this study indicated that after 10 cycles of torquing and reverse torquing attachment screws, the reverse torque values decreased. There were no statistical differences between the magnitude of torque necessary to fracture new and used attachment screws.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/jopr.13916","type":"journal-article","created":{"date-parts":[[2024,7,25]],"date-time":"2024-07-25T23:25:39Z","timestamp":1721949939000},"page":"867-872","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["In vitro study to analyze reverse torque values of attachment screws with multiple loosening\/tightening preload cycles"],"prefix":"10.1111","volume":"34","author":[{"given":"Amira","family":"Alhameed","sequence":"first","affiliation":[{"name":"Associate Consultant of Prosthodontics King Abdullah Medical City Specialist Hospital  Makkah Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3046-575X","authenticated-orcid":false,"given":"Nikita","family":"Sinha","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics Creighton University School of Dentistry  Omaha Nebraska USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-5893-4869","authenticated-orcid":false,"given":"Geoffrey A.","family":"Thompson","sequence":"additional","affiliation":[{"name":"Graduate Prosthodontics Marquette University School of Dentistry  Milwaukee Wisconsin USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8128-9162","authenticated-orcid":false,"given":"Carl","family":"Drago","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics Marquette University School of Dentistry  Milwaukee Wisconsin USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0658-2924","authenticated-orcid":false,"given":"Hongseok","family":"An","sequence":"additional","affiliation":[{"name":"Department of Oral Rehabilitation and Biosciences Oregon Health &amp; Science University  Portland Oregon USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2024,7,25]]},"reference":[{"issue":"4","key":"e_1_2_7_2_1","first-page":"425","article-title":"Long\u2010term treatment outcomes in edentulous patients with implant overdentures: the Toronto study","volume":"17","author":"Attard NJ","year":"2004","journal-title":"Int J Prosthodont"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2008.01699.x"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2016.12.001"},{"issue":"5","key":"e_1_2_7_5_1","first-page":"529","article-title":"Elongation and preload stress in dental implant abutment screws","volume":"10","author":"Haack JE","year":"1995","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2014.11.017"},{"issue":"4","key":"e_1_2_7_7_1","first-page":"347","article-title":"Long\u2010term follow\u2010up study of osseointegrated implants in the treatment of totally edentulous jaws","volume":"5","author":"Adell R","year":"1990","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"1","key":"e_1_2_7_8_1","first-page":"S27","article-title":"Prosthetic complications with implant prostheses (2001\u20102017)","volume":"11","author":"Goodacre BJ","year":"2018","journal-title":"Eur J Oral Implantol"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(94)90443-X"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(05)80229-X"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2004.01117.x"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2007.01439.x"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.13119"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(90)90153-4"},{"issue":"3","key":"e_1_2_7_15_1","first-page":"241","article-title":"Forces and moments on Branemark implants","volume":"4","author":"Rangert B","year":"1989","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"1","key":"e_1_2_7_16_1","first-page":"76","article-title":"Implants and components: entering the new millennium","volume":"15","author":"Binon PP","year":"2000","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1201\/9780429243943"},{"key":"e_1_2_7_18_1","unstructured":"PiermattiJ BarndtP ThaljiG. Position Statemen\u00a0Maintenance of full\u2010arch implant restorations. Position statement of theAmerican College of Prosthodontists.2016.https:\/\/www.prosthodontics.org\/about\u2010acp\/position\u2010statement\u2010maintenance\u2010of\u2010full\u2010arch\u2010implant\u2010restorations\/"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1067\/mpr.2000.108069"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2008.01690.x"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2011.02165.x"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1067\/mpr.2002.127604"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1111\/ffe.13399"},{"key":"e_1_2_7_24_1","doi-asserted-by":"publisher","DOI":"10.1067\/mpr.2001.114266"},{"issue":"1","key":"e_1_2_7_25_1","first-page":"38","article-title":"Changes in prosthetic screw stability because of misfit of implant\u2010supported prostheses","volume":"15","author":"Al\u2010Turki LE","year":"2002","journal-title":"Int J Prosthodont"}],"container-title":["Journal of Prosthodontics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jopr.13916","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,22]],"date-time":"2025-10-22T07:08:10Z","timestamp":1761116890000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jopr.13916"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,25]]},"references-count":24,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2025,10]]}},"alternative-id":["10.1111\/jopr.13916"],"URL":"https:\/\/doi.org\/10.1111\/jopr.13916","archive":["Portico"],"relation":{},"ISSN":["1059-941X","1532-849X"],"issn-type":[{"value":"1059-941X","type":"print"},{"value":"1532-849X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,25]]},"assertion":[{"value":"2023-04-10","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-07-11","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-07-25","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}