{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T00:36:26Z","timestamp":1788827786091,"version":"build-2803163510"},"reference-count":28,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2024,9,24]],"date-time":"2024-09-24T00:00:00Z","timestamp":1727136000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["82270998"],"award-info":[{"award-number":["82270998"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100003399","name":"Science and Technology Commission of Shanghai Municipality","doi-asserted-by":"publisher","award":["21Y11903800"],"award-info":[{"award-number":["21Y11903800"]}],"id":[{"id":"10.13039\/501100003399","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Journal of Prosthodontics"],"published-print":{"date-parts":[[2025,3]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>The purpose of this study was to assess the precision and trueness of three jaw motion tracking systems, the KaVo ARCUSdigma system, SDiMatriX system, and Modjaw system, in recording mandibular movements based on optical and ultrasonic principles.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods<\/jats:title>\n                    <jats:p>\n                      Twenty\u2010five healthy subjects were selected for the present study to measure protrosive movement and left and right lateral movements using the three jaw motion tracking systems. Each subject's mandibular movement was recorded twice with a 1\u2010week interval. Five parameters\u2014sagittal condylar inclination (SCI) angle, incisal guide angle, Bennett angle, lateral condylar inclination angle, and Fischer's angle\u2014were acquired for further analysis. The precision of the jaw motion tracking systems was evaluated by comparing the results of two measurements of the same parameter. Simultaneously, cone beam computed tomography (CBCT) was utilized during the initial data acquisition and was aligned with intercuspal position (ICP) and edge\u2010to\u2010edge occlusion intraoral scan data. Bone landmarks were used to calculate bilateral SCI as a reference for comparison with the SCI values from each jaw motion tracking system. An independent\u2010sample\n                      <jats:italic>t<\/jats:italic>\n                      \u2010test was conducted to compare parameter differences, with statistical significance set at a\n                      <jats:italic>p<\/jats:italic>\n                      \u2010value below 0.05.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      There were no significant differences among the three jaw motion tracking systems regarding the corrected values of SCI, incisal guide angle, Bennett angle, lateral condylar inclination angle, and Fischer's angle during the 1\u2010week interval (\n                      <jats:italic>p\u00a0<\/jats:italic>\n                      &gt;\u00a00.05). The values of bilateral SCI obtained by CBCT were 48.57\u00a0\u00b1\u00a06.74 (L) and 48.35\u00a0\u00b1\u00a05.28 (R), respectively. No significant differences were found between the reference SCI and those parameters measured by the KaVo ARCUSdigma system and the Modjaw system (\n                      <jats:italic>p\u00a0<\/jats:italic>\n                      &gt;\u00a00.05), while the results obtained from the SDiMatriX system indicated a significant difference compared to the reference SCI (\n                      <jats:italic>p\u00a0<\/jats:italic>\n                      &lt;\u00a00.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The three jaw motion tracking systems exhibited favorable results in terms of precision. Regarding trueness, both the KaVo ARCUSdigma system and the Modjaw system demonstrated a satisfactory levels suitable for applications in digital prosthodontics within clinical settings. However, further refinement is needed to enhance the trueness of the SDiMatriX system.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/jopr.13953","type":"journal-article","created":{"date-parts":[[2024,9,25]],"date-time":"2024-09-25T09:57:02Z","timestamp":1727258222000},"page":"263-270","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Comparative analysis of three jaw motion tracking systems: A study on precision and trueness"],"prefix":"10.1111","volume":"34","author":[{"given":"Wei","family":"Zhao","sequence":"first","affiliation":[{"name":"Shanghai Engineering Research Center of Tooth Restoration and Regeneration &amp; Tongji Research Institute of Stomatology &amp; Department of Prosthodontics Stomatological Hospital and Dental School Tongji University  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4862-693X","authenticated-orcid":false,"given":"Yue","family":"Feng","sequence":"additional","affiliation":[{"name":"Shanghai Engineering Research Center of Tooth Restoration and Regeneration &amp; Tongji Research Institute of Stomatology &amp; Department of Prosthodontics Stomatological Hospital and Dental School Tongji University  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rongkai","family":"Cao","sequence":"additional","affiliation":[{"name":"Shanghai Engineering Research Center of Tooth Restoration and Regeneration &amp; Tongji Research Institute of Stomatology &amp; Department of Prosthodontics Stomatological Hospital and Dental School Tongji University  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiyu","family":"Sun","sequence":"additional","affiliation":[{"name":"Shanghai Engineering Research Center of Tooth Restoration and Regeneration &amp; Tongji Research Institute of Stomatology &amp; Department of Prosthodontics Stomatological Hospital and Dental School Tongji University  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiayao","family":"Zhang","sequence":"additional","affiliation":[{"name":"Shanghai Engineering Research Center of Tooth Restoration and Regeneration &amp; Tongji Research Institute of Stomatology &amp; Department of Prosthodontics Stomatological Hospital and Dental School Tongji University  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xinhuan","family":"Zhao","sequence":"additional","affiliation":[{"name":"Shanghai Engineering Research Center of Tooth Restoration and Regeneration &amp; Tongji Research Institute of Stomatology &amp; Department of Prosthodontics Stomatological Hospital and Dental School Tongji University  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weicai","family":"Liu","sequence":"additional","affiliation":[{"name":"Shanghai Engineering Research Center of Tooth Restoration and Regeneration &amp; Tongji Research Institute of Stomatology &amp; Department of Prosthodontics Stomatological Hospital and Dental School Tongji University  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2024,9,24]]},"reference":[{"issue":"5","key":"e_1_2_9_2_1","first-page":"428","article-title":"Comparative study on measurement of mandibular movement by electronic facebow and digital caliper","volume":"18","author":"Bo P","year":"2022","journal-title":"J Tissue Eng\u00a0Reconstr Surg"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2015.04.003"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1159\/000397870"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1093\/ejo\/cjaa033"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0722.2006.00402.x"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajodo.2009.12.015"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2020.109994"},{"issue":"7","key":"e_1_2_9_9_1","first-page":"1254","article-title":"Methods of recording mandibular movements\u2010a review","volume":"10","author":"Madhavan S","year":"2018","journal-title":"Drug Invent\u00a0Today"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.4317\/medoral.17147"},{"issue":"6","key":"e_1_2_9_11_1","first-page":"445","article-title":"[Results of incorrectly positioned hinge axis on axiographic tracings of mandibular movement]","volume":"99","author":"Lotzmann U","year":"1990","journal-title":"ZWR"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.15644\/asc53\/3\/3"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(80)90464-3"},{"key":"e_1_2_9_14_1","first-page":"1","article-title":"Modjaw\u00ae device: analysis of mandibular kinematics recorded for a group of asymptomatic subjects","author":"Bapelle M","year":"2021","journal-title":"Cranio"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.3934\/mbe.2020307"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2021.06.007"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2021.05.019"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.4047\/jap.2023.15.1.11"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajodo.2008.02.017"},{"key":"e_1_2_9_20_1","doi-asserted-by":"publisher","DOI":"10.1051\/odfen\/2010105"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.13143"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2022.12.007"},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(77)90268-2"},{"key":"e_1_2_9_24_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.13517"},{"key":"e_1_2_9_25_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.13035"},{"key":"e_1_2_9_26_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.13023"},{"issue":"1","key":"e_1_2_9_27_1","first-page":"24","article-title":"The effect of complete denture occlusion on function and patient quality of life: systematic review","volume":"26","author":"Patel J","year":"2018","journal-title":"Eur J Prosthodont Restor Dent"},{"key":"e_1_2_9_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(91)90168-V"},{"key":"e_1_2_9_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(91)90228-O"}],"container-title":["Journal of Prosthodontics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jopr.13953","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,11]],"date-time":"2025-03-11T17:52:03Z","timestamp":1741715523000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jopr.13953"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,24]]},"references-count":28,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025,3]]}},"alternative-id":["10.1111\/jopr.13953"],"URL":"https:\/\/doi.org\/10.1111\/jopr.13953","archive":["Portico"],"relation":{},"ISSN":["1059-941X","1532-849X"],"issn-type":[{"value":"1059-941X","type":"print"},{"value":"1532-849X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,9,24]]},"assertion":[{"value":"2024-05-16","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-08-28","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-09-24","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}