{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,24]],"date-time":"2026-04-24T07:01:51Z","timestamp":1777014111966,"version":"3.51.4"},"reference-count":44,"publisher":"Wiley","license":[{"start":{"date-parts":[[2024,11,12]],"date-time":"2024-11-12T00:00:00Z","timestamp":1731369600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Journal of Prosthodontics"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Purpose<\/jats:title><jats:p>This study investigated the effect of three digital bite registration techniques on the accuracy of intraoral scanning in maxillary edentulous and mandibular dentate arches.<\/jats:p><\/jats:sec><jats:sec><jats:title>Materials and Methods<\/jats:title><jats:p>Maxillary edentulous and mandible fully dentate models were created. Four dental implants were placed in the maxilla, fitted with scan bodies, and reference scans were obtained using a Nikon Altera 10.7.6 scanner. Digital impressions were acquired 10 times for each model using a Trios 4 intraoral scanner. Three different digital bite records were collected for each pair of mandible and maxilla scans. The first one was a bite record without additional material (WSB), the second utilized a silicone index between the models (WSB silicone), and the third followed a pre\u2010preparation scanning protocol (Pre\u2010PREP). The data was exported in standard tessellation language (STL) format, which was assessed for trueness and precision using statistical analysis.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>According to mean trueness values, WSB exhibited the lowest value, 173 \u00b5m, followed by WSB silicone 242 \u00b5m and Pre\u2010PREP 620 \u00b5m. The differences were significant only when comparing Pre\u2010PREP to WSB and Pre\u2010PREP to WSB silicone (<jats:italic>p<\/jats:italic> &lt;\u00a00.05). Regarding precision, WSB demonstrated a mean value of 171.5 \u00b5m, followed by WSB silicone with 213.8 \u00b5m, and Pre\u2010PREP with 222.2 \u00b5m with no significant difference between the groups.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The presence of interarch bite registration material adversely affected interocclusal record accuracy, while WSB silicone presented a suitable substitute for WSB.<\/jats:p><\/jats:sec>","DOI":"10.1111\/jopr.13976","type":"journal-article","created":{"date-parts":[[2024,11,12]],"date-time":"2024-11-12T16:09:03Z","timestamp":1731427743000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Accuracy of different maxillomandibular relationship recording techniques in the edentulous maxillary arch"],"prefix":"10.1111","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3132-2646","authenticated-orcid":false,"given":"Justinas","family":"Pletkus","sequence":"first","affiliation":[{"name":"Department of Prosthodontics, Institute of Odontology, Faculty of Medicine, Digitorum Research Center Vilnius University  Vilnius Lithuania"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Liudas","family":"Au\u0161kalnis","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Institute of Odontology, Faculty of Medicine, Digitorum Research Center Vilnius University  Vilnius Lithuania"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ieva","family":"Gendvilien\u0117","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Institute of Odontology, Faculty of Medicine, Digitorum Research Center Vilnius University  Vilnius Lithuania"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rolandas","family":"Pletkus","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Institute of Odontology, Faculty of Medicine, Digitorum Research Center Vilnius University  Vilnius Lithuania"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0308-9579","authenticated-orcid":false,"given":"Tan F\u0131rat","family":"Ey\u00fcbo\u011flu","sequence":"additional","affiliation":[{"name":"Department of Endodontics, Faculty of Dentistry Istanbul Medipol University  Baltimore Istanbul Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mutlu","family":"\u00d6zcan","sequence":"additional","affiliation":[{"name":"Division of Dental Biomaterials, Clinic for Reconstructive Dentistry University of Zurich  Zurich Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mykolas","family":"Akulauskas","sequence":"additional","affiliation":[{"name":"Department of Electronics Engineering Biomedical Engineering Institute Kaunas University of Technology  Kaunas Lithuania"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vygandas","family":"Rutk\u016bnas","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Institute of Odontology, Faculty of Medicine, Digitorum Research Center Vilnius University  Vilnius Lithuania"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2024,11,12]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2021.09.017"},{"issue":"9","key":"e_1_2_8_3_1","first-page":"727","article-title":"Evaluation of vertical accuracy of interocclusal recording materials","volume":"39","author":"Ghazal M","year":"2008","journal-title":"Quintessence Int"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/s0022\u20103913(97)70227\u20100"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijom.2010.02.002"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2018.08.016"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpor.2019.12.003"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.13597"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.4047\/jap.2019"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2020.07.017"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00784\u2010020\u201003343\u2010z"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.13749"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2017.07.007"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2017.06.019"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.12786"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpor.2019.04.009"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2007.08.008"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.3390\/jcm11102882"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajodo.2015.04.025"},{"key":"e_1_2_8_20_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.13359"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.11607\/jomi.4854"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.13844"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2024.105050"},{"key":"e_1_2_8_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2016.09.016"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.3290\/j.qi.a35524"},{"key":"e_1_2_8_26_1","doi-asserted-by":"publisher","DOI":"10.1155\/2017\/8427595"},{"key":"e_1_2_8_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2019.06.003"},{"key":"e_1_2_8_28_1","doi-asserted-by":"publisher","DOI":"10.11607\/jomi.5087"},{"key":"e_1_2_8_29_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00170\u2010008\u20101794\u20109"},{"key":"e_1_2_8_30_1","doi-asserted-by":"publisher","DOI":"10.1922\/EJPRD_01752Abduo21"},{"key":"e_1_2_8_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2019.12.011"},{"key":"e_1_2_8_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2017.05.002"},{"key":"e_1_2_8_33_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00784\u2010020\u201003486\u2010z"},{"key":"e_1_2_8_34_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.13264"},{"key":"e_1_2_8_35_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2020.12.037"},{"key":"e_1_2_8_36_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2018.06.022"},{"key":"e_1_2_8_37_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2021.10.017"},{"key":"e_1_2_8_38_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2023.07.028"},{"key":"e_1_2_8_39_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12903\u2010022\u201002612\u20105"},{"issue":"1","key":"e_1_2_8_40_1","first-page":"101","article-title":"Accuracy of digital implant impressions with intraoral scanners. A systematic review","volume":"10","author":"Rutk\u016bnas V","year":"2017","journal-title":"Eur J Oral Implantol"},{"key":"e_1_2_8_41_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12903\u2010021\u201001398\u20102"},{"key":"e_1_2_8_42_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708\u20108208.2008.00110.x"},{"key":"e_1_2_8_43_1","doi-asserted-by":"publisher","DOI":"10.3390\/dj11100241"},{"key":"e_1_2_8_44_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpor.2019.05.005"},{"key":"e_1_2_8_45_1","doi-asserted-by":"publisher","DOI":"10.11607\/ijp.5624"}],"container-title":["Journal of Prosthodontics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jopr.13976","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,15]],"date-time":"2024-11-15T10:54:40Z","timestamp":1731668080000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jopr.13976"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,12]]},"references-count":44,"alternative-id":["10.1111\/jopr.13976"],"URL":"https:\/\/doi.org\/10.1111\/jopr.13976","archive":["Portico"],"relation":{},"ISSN":["1059-941X","1532-849X"],"issn-type":[{"value":"1059-941X","type":"print"},{"value":"1532-849X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,11,12]]},"assertion":[{"value":"2023-12-29","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-10-12","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-11-12","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"jopr.13976"}}