{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,8]],"date-time":"2026-06-08T23:06:57Z","timestamp":1780960017682,"version":"3.54.1"},"reference-count":22,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2025,1,23]],"date-time":"2025-01-23T00:00:00Z","timestamp":1737590400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2025,1,23]],"date-time":"2025-01-23T00:00:00Z","timestamp":1737590400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Journal of Prosthodontics"],"published-print":{"date-parts":[[2026,3]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>The primary objective of this retrospective study was to evaluate the survival outcomes of immediately loaded acrylic resin complete arch fixed implant\u2010supported prosthesis (CAFIP) fabricated from the denture conversion protocol. The secondary objective was to evaluate the early implant survival outcomes associated with these prostheses.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Material and Methods<\/jats:title>\n                    <jats:p>\n                      A retrospective chart review was conducted to study the clinical outcomes data of immediately loaded conversion prostheses and immediately loaded implants. All patients who had been treated with immediately loaded acrylic resin CAFIP using the denture conversion protocol over a 9\u2010year period were included in the study. All dentures were fabricated by conventional processing using compression molded or injection molded techniques. These patients were treated by numerous clinicians but adhering to the same protocol, over the entire 9\u2010year follow\u2010up period. Clinical outcome data related to the number of early fractures during the initial implant healing period of 4 months, early implant failures, late fractures (after 4 months), late implant failures (after 4 months), technical complications, number and type of implants placed, the arch in which the implants and prosthesis were placed and the type of opposing dentition were recorded and analyzed. A\n                      <jats:italic>p<\/jats:italic>\n                      \u2010value\u00a0&lt;\u00a00.05 was determined to be statistically significant.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      A total of 153 prostheses (97 in maxilla, 56 in mandible) in 117 patients (60 males, 57 females) and 768 implants (298 in maxilla, 470 in mandible) were evaluated. All conversion prostheses were followed up for a minimum of 4 months (range of 4\u201320 months). There were a total of 15 implant failures yielding a survival rate of 98% survival rate during the observation period with the conversion prostheses. Only 3 of the failed implants were associated with a failure (crack or fracture) of the conversion prosthesis (maxilla) during the 4\u2010month healing period. There were a total of 9 conversion prostheses with cracks or fractures during the 4\u2010month healing period (early critical complication), yielding a complication\u2010free survival rate of 94.1%. There were 6 additional early noncritical prosthetic complications such as tooth debonding or chipping during the 4\u2010month period. Only the early critical prosthetic complication rates comparing maxilla and mandible were statistically significant (\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0=\u00a00.037).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The findings from this retrospective study revealed a high early survival rate for dental implants (98%) and for the immediately loaded acrylic resin CAFIP fabricated from the denture conversion protocol (94%). There were minimal additional implant failures and noncritical complications related to the conversion prosthesis. The denture conversion protocol is a simple evidence\u2010based technique and serves as an excellent and predictable method for the immediate loading of dental implants.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/jopr.14019","type":"journal-article","created":{"date-parts":[[2025,1,23]],"date-time":"2025-01-23T23:23:11Z","timestamp":1737674591000},"page":"316-322","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Clinical outcomes of conversion prosthesis in immediately loaded implants: A retrospective study"],"prefix":"10.1111","volume":"35","author":[{"given":"Karolina M.","family":"Migus","sequence":"first","affiliation":[{"name":"Department of Prosthodontics University of Connecticut Health Center  Farmington Connecticut USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8831-8096","authenticated-orcid":false,"given":"Avinash S.","family":"Bidra","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics University of Connecticut Health Center  Farmington Connecticut USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chia\u2010Ling","family":"Kuo","sequence":"additional","affiliation":[{"name":"Department of Community Medicine and Health Care University of Connecticut Health Center  Farmington Connecticut USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,1,23]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1097\/00008505-200110000-00004"},{"key":"e_1_2_7_3_1","first-page":"495","article-title":"Ten\u2010year results for Br\u00e5nemark implants immediately loaded with fixed prostheses at implant placement","volume":"12","author":"Schnitman PA","year":"1997","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.13116"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/cid.12769"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1111\/cid.12771"},{"key":"e_1_2_7_7_1","first-page":"249","article-title":"Systematic review of survival rates for immediately loaded dental implants","volume":"26","author":"Del Fabbro M","year":"2006","journal-title":"Int J Periodontics Restorative Dent"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2006.01348.x"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2019.05.013"},{"key":"e_1_2_7_10_1","first-page":"667","article-title":"The Biotes conversion prosthesis: a provisional fixed prosthesis supported by osseointegrated titanium fixtures for restoration of the edentulous jaw","volume":"16","author":"Balshi TJ","year":"1985","journal-title":"Quintessence Int"},{"key":"e_1_2_7_11_1","first-page":"106","article-title":"Conversion prosthesis: a transitional fixed implant\u2010supported prosthesis for an edentulous arch\u2013a technical note","volume":"11","author":"Balshi TJ","year":"1996","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_7_12_1","first-page":"37","article-title":"Immediate loading of dental implants in the edentulous maxilla: case study of a unique protocol","volume":"23","author":"Balshi TJ","year":"2003","journal-title":"Int J Periodontics Restorative Dent"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.12228"},{"key":"e_1_2_7_14_1","first-page":"894","article-title":"Biomechanical implant treatment complications: a systematic review of clinical studies of implants with at least 1 year of functional loading","volume":"27","author":"Hsu YT","year":"2012","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2004.08.003"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.13105"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2003.tb00010.x"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.13323"},{"key":"e_1_2_7_19_1","article-title":"Comparison of strength of milled and conventionally processed PMMA complete\u2010arch implant\u2010supported immediate interim fixed dental prostheses","author":"Angelara K","year":"2021","journal-title":"J Prosthet Dent"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2015.08.016"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.12364"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2018.10.009"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.12343"}],"container-title":["Journal of Prosthodontics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jopr.14019","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/jopr.14019","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jopr.14019","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,16]],"date-time":"2026-03-16T09:29:48Z","timestamp":1773653388000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jopr.14019"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,23]]},"references-count":22,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,3]]}},"alternative-id":["10.1111\/jopr.14019"],"URL":"https:\/\/doi.org\/10.1111\/jopr.14019","archive":["Portico"],"relation":{},"ISSN":["1059-941X","1532-849X"],"issn-type":[{"value":"1059-941X","type":"print"},{"value":"1532-849X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,23]]},"assertion":[{"value":"2024-09-13","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-12-20","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-01-23","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}