{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,16]],"date-time":"2026-03-16T10:08:09Z","timestamp":1773655689899,"version":"3.50.1"},"reference-count":28,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T00:00:00Z","timestamp":1740096000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T00:00:00Z","timestamp":1740096000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Journal of Prosthodontics"],"published-print":{"date-parts":[[2026,3]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To assess the precision of implant placement when comparing tilted orientations to axial orientations, utilizing a fully guided surgical protocol in an edentulous mandibular model.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods<\/jats:title>\n                    <jats:p>Fourteen rubber\u2010coated mandibular models were scanned with fiducial markers using a commercial benchtop surface scanner, followed by cone beam computed tomography for implant planning through a dual\u2010scan protocol. The models were randomly divided into control and experimental groups. In the control group, each model was planned for four axially oriented implants. Conversely, the experimental models were planned for two axially oriented implants near the lateral incisors and two posteriorly tilted implants at a 30\u2010degree angle. A mucosal\u2010supported, pin\u2010retained surgical guide was designed and 3D\u2010printed, facilitating the fully guided implant placement. All implants received scan bodies and were rescanned for evaluation of the trueness between the planned and the actual implant location using the implant planning software. Mixed model ANOVA was used to detect differences between groups with regards to angular deviation, offset at base, and offset at tip.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      A total of 56 implants were placed across all models. Fourteen posterior implants in each group served as control and experimental conditions, while the remaining 28 anterior implants acted as secondary control. No significant differences were observed between the experimental and control groups in terms of angular deviation (\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0=\u00a00.7001), offset at base (\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0=\u00a00.6409), or offset at tip (\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0=\u00a00.6931). Analysis comparing anterior implant deviations between groups and anterior to posterior implant deviations within the control arches also was not significant. However, secondary analysis revealed a significant difference between anterior and posterior implants within the experimental group for offset at base (\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0=\u00a00.0087) and offset at tip (\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0=\u00a00.0288).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Despite the limitations inherent to a benchtop study, the findings suggest that there are no statistically significant 3D deviations at the base or apex, nor in angular deviations, when comparing tilted and axial implant placements using a digital workflow and fully guided protocols in an edentulous model.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/jopr.14037","type":"journal-article","created":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T04:50:51Z","timestamp":1740113451000},"page":"367-374","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["An in vitro assessment of the accuracy of guided tilted and axial implant placement in the edentulous mandible"],"prefix":"10.1111","volume":"35","author":[{"given":"Brett C.","family":"Freeman","sequence":"first","affiliation":[{"name":"Department of Periodontology Indiana University School of Dentistry  Indianapolis Indiana USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hawra","family":"Alqallaf","sequence":"additional","affiliation":[{"name":"Department of Periodontology Indiana University School of Dentistry  Indianapolis Indiana USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6008-0650","authenticated-orcid":false,"given":"Chao\u2010Chieh","family":"Yang","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Advanced Education Program in Prosthodontics Indiana University School of Dentistry  Indianapolis Indiana USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4881-0569","authenticated-orcid":false,"given":"Wei\u2010Shao","family":"Lin","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics Indiana University School of Dentistry  Indianapolis Indiana USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0534-3067","authenticated-orcid":false,"given":"Vinicius","family":"Dutra","sequence":"additional","affiliation":[{"name":"Department of Oral Pathology, Medicine, and Radiology Indiana University School of Dentistry  Indianapolis Indiana USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8544-8418","authenticated-orcid":false,"given":"Yusuke","family":"Hamada","sequence":"additional","affiliation":[{"name":"Section of Periodontics UCLA School of Dentistry  Los Angeles California USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2025,2,21]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1177\/0022034518792567"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.12514"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/prd.12292"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/prd.12185"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2003.tb00010.x"},{"key":"e_1_2_7_7_1","first-page":"405","article-title":"Tilting of posterior mandibular and maxillary implants for improved prosthesis support","volume":"15","author":"Krekmanov L","year":"2000","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_7_8_1","first-page":"241","article-title":"Forces and moments on Branemark implants","volume":"4","author":"Rangert B","year":"1989","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_7_9_1","first-page":"2","article-title":"Critical A\u2010P spread","volume":"1","author":"English CE","year":"1990","journal-title":"Implant Soc"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2001.tb00127.x"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2010.00288.x"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1177\/0022034512455802"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2010.00304.x"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00784-005-0031-2"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1111\/prd.12056"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.aanat.2019.04.005"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.13346"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.11607\/jomi.5556"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2012.02552.x"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.11607\/jomi.7942"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.13294"},{"issue":"5","key":"e_1_2_7_22_1","first-page":"663","article-title":"A custom template and definitive prosthesis allowing immediate implant loading in the maxilla: a clinical report","volume":"17","author":"Steenberghe D","year":"2002","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2019.07.010"},{"key":"e_1_2_7_24_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2010.01957.x"},{"key":"e_1_2_7_25_1","doi-asserted-by":"publisher","DOI":"10.5037\/jomr.2018.9101"},{"key":"e_1_2_7_26_1","doi-asserted-by":"publisher","DOI":"10.4103\/ejd.ejd_249_17"},{"key":"e_1_2_7_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2013.07.029"},{"key":"e_1_2_7_28_1","doi-asserted-by":"publisher","DOI":"10.11607\/jomi.3329"},{"key":"e_1_2_7_29_1","doi-asserted-by":"publisher","DOI":"10.3390\/jcm13175178"}],"container-title":["Journal of Prosthodontics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jopr.14037","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/jopr.14037","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jopr.14037","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,16]],"date-time":"2026-03-16T09:29:38Z","timestamp":1773653378000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jopr.14037"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,21]]},"references-count":28,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,3]]}},"alternative-id":["10.1111\/jopr.14037"],"URL":"https:\/\/doi.org\/10.1111\/jopr.14037","archive":["Portico"],"relation":{},"ISSN":["1059-941X","1532-849X"],"issn-type":[{"value":"1059-941X","type":"print"},{"value":"1532-849X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,21]]},"assertion":[{"value":"2024-05-05","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-01-26","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-02-21","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}