{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T18:27:12Z","timestamp":1754159232456,"version":"3.41.2"},"reference-count":30,"publisher":"Wiley","license":[{"start":{"date-parts":[[2025,7,24]],"date-time":"2025-07-24T00:00:00Z","timestamp":1753315200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Journal of Prosthodontics"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Purpose<\/jats:title><jats:p>The aim of this study was to investigate the impact of an increasing level of monomer contamination of isopropanol (isopropyl alcohol [IPA]) during post\u2010rinsing on the dimensional stability of test samples produced by vat photopolymerization. The effect of resin deposits due to insufficient post\u2010rinsing on the accuracy (volume, mean, and maximum deviation) of additive manufacturing workflows was investigated, which has received limited attention in studies on accuracy.<\/jats:p><\/jats:sec><jats:sec><jats:title>Materials and Methods<\/jats:title><jats:p>Forty test specimens (four groups, <jats:italic>n<\/jats:italic> = 10) were produced from a commonly used resin for dental model fabrication and underwent post\u2010rinsing in IPA with different levels of monomer contamination (0, 10, 20, and 30\u00a0wt%). The dimensional stability was assessed by comparing the optical scan of the produced test specimens with the original digital design. Both the volume of the deposited resin and the effect of different model shapes (inner edges, smooth surfaces, and outer edges) on deposition were investigated. Statistical evaluation was performed using the Kruskal\u2013Wallis test and Dunn's test for pairwise comparisons with Holm correction. To simulate clinical conditions, 20 dental models (four groups, <jats:italic>n<\/jats:italic> = 5) were produced, post\u2010processed, and examined using a scanning method.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>No significant deviations in specimen dimensions occurred when the monomer contamination was 0%\u201310%. In the range of 10%\u201320% contamination, a few significant deviations occurred in the area of sharp inner edges, \u201cinside structures\u201d and small structures (diameter &lt;1000\u00a0\u00b5m). At contamination levels of 30%, significant deviations were observed eventually in all measured areas.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>This study showed that, contrary to the manufacturer's specifications, the IPA should only be replaced during post\u2010rinsing if the monomer contamination of the rinsing solution is &gt;20%. At contamination levels of 10%\u201320%, post\u2010rinsing of components with large smooth surfaces without sharp edges (e.g., custom trays) is possible without significant deformation. Only for components with very small, sharp\u2010edged, or inverted structures is it advisable to replace the IPA from a contamination level of 10%.<\/jats:p><\/jats:sec>","DOI":"10.1111\/jopr.70011","type":"journal-article","created":{"date-parts":[[2025,7,25]],"date-time":"2025-07-25T03:35:02Z","timestamp":1753414502000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Impact of monomer contamination of isopropanol during post\u2010rinsing on the accuracy of dental models fabricated by vat photopolymerization"],"prefix":"10.1111","author":[{"given":"Florian","family":"Flierl","sequence":"first","affiliation":[{"name":"Center for Dental Medicine Department of Prosthetic Dentistry Faculty of Medicine University of Freiburg  Freiburg Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1702-1679","authenticated-orcid":false,"given":"Benedikt C.","family":"Spies","sequence":"additional","affiliation":[{"name":"Center for Dental Medicine Department of Prosthetic Dentistry Faculty of Medicine University of Freiburg  Freiburg Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Severin","family":"Rothlauf","sequence":"additional","affiliation":[{"name":"Center for Dental Medicine Department of Prosthetic Dentistry Faculty of Medicine University of Freiburg  Freiburg Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9278-2203","authenticated-orcid":false,"given":"Kirstin","family":"Vach","sequence":"additional","affiliation":[{"name":"Institute of Medical Biometry and Statistics Faculty of Medicine University of Freiburg  Freiburg Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7095-4190","authenticated-orcid":false,"given":"Ralf J.","family":"Kohal","sequence":"additional","affiliation":[{"name":"Center for Dental Medicine Department of Prosthetic Dentistry Faculty of Medicine University of Freiburg  Freiburg Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3744-2107","authenticated-orcid":false,"given":"J\u00f6rg","family":"L\u00fcchtenborg","sequence":"additional","affiliation":[{"name":"Center for Dental Medicine Department of Prosthetic Dentistry Faculty of Medicine University of Freiburg  Freiburg Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2025,7,24]]},"reference":[{"issue":"2","key":"e_1_2_9_2_1","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1111\/jopr.12801","article-title":"Additive manufacturing technologies used for processing polymers: current status and potential application in prosthetic dentistry","volume":"28","author":"Revilla\u2010Le\u00f3n M","year":"2019","journal-title":"J Prosthodont"},{"key":"e_1_2_9_3_1","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2021.103630","article-title":"3D printing parameters, supporting structures, slicing, and post\u2010processing procedures of vat\u2010polymerization additive manufacturing technologies: a narrative review","volume":"109","author":"Piedra\u2010Casc\u00f3n W","year":"2021","journal-title":"J Dent"},{"issue":"2","key":"e_1_2_9_4_1","doi-asserted-by":"crossref","first-page":"336","DOI":"10.1016\/j.dental.2020.11.030","article-title":"3D printing restorative materials using a stereolithographic technique: a systematic review","volume":"37","author":"Della Bona A","year":"2021","journal-title":"Dent Mater"},{"issue":"4","key":"e_1_2_9_5_1","doi-asserted-by":"crossref","first-page":"321","DOI":"10.4047\/jap.2018.10.4.321","article-title":"A study on the machining accuracy of dental digital method focusing on dental inlay","volume":"10","author":"Bae EJ","year":"2018","journal-title":"J Adv Prosthodont"},{"issue":"1","key":"e_1_2_9_6_1","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1111\/jopr.13227","article-title":"Effects of two postprocessing methods onto surface dimension of in\u2010office fabricated stereolithographic implant surgical guides","volume":"30","author":"Ammoun R","year":"2021","journal-title":"J Prosthodont"},{"issue":"1","key":"e_1_2_9_7_1","first-page":"1","article-title":"The influence of the post\u2010processing method on knoop hardness of photosensitive resins for 3D SLA printer used in Dentistry","volume":"2019","author":"Torres Vasques M","year":"2019","journal-title":"Clin Lab Res Dent"},{"issue":"1","key":"e_1_2_9_8_1","doi-asserted-by":"crossref","first-page":"45","DOI":"10.4047\/jap.2022.14.1.45","article-title":"Effect of post\u2010rinsing time and method on accuracy of denture base manufactured with stereolithography","volume":"14","author":"Katheng A","year":"2022","journal-title":"J Adv Prosthodont"},{"issue":"2","key":"e_1_2_9_9_1","doi-asserted-by":"crossref","first-page":"11","DOI":"10.24867\/JGED-2020-2-011","article-title":"Environmental impact of printing inks and printing process","volume":"11","author":"Aydemir C","year":"2020","journal-title":"J Graph Eng Des"},{"key":"e_1_2_9_10_1","doi-asserted-by":"crossref","DOI":"10.1016\/j.apmt.2020.100689","article-title":"On the environmental impacts of 3D printing technology","volume":"20","author":"Khosravani MR","year":"2020","journal-title":"Appl Mater Today"},{"issue":"5","key":"e_1_2_9_11_1","doi-asserted-by":"crossref","first-page":"470","DOI":"10.3109\/15563650.2014.914527","article-title":"Isopropanol poisoning","volume":"52","author":"Slaughter RJ","year":"2014","journal-title":"Clin Toxicol (Phila)"},{"issue":"3","key":"e_1_2_9_12_1","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1067\/mpr.2002.128122","article-title":"Secondary caries in crowned teeth: correlation of clinical and radiographic findings","volume":"88","author":"Zoellner A","year":"2002","journal-title":"J Prosthet Dent"},{"issue":"1","key":"e_1_2_9_13_1","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1016\/0022-3913(71)90150-8","article-title":"Clinical and research advancements in cast\u2010gold restorations","volume":"25","author":"Christensen GJ","year":"1971","journal-title":"J Prosthet Dent"},{"issue":"5","key":"e_1_2_9_14_1","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/S0109-5641(85)80019-1","article-title":"The fit of metal\u2010ceramic crowns, a clinical study","volume":"1","author":"Fransson B","year":"1985","journal-title":"Dent Mater"},{"issue":"4","key":"e_1_2_9_15_1","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1067\/mpr.2000.109125","article-title":"Clinical fit of Procera AllCeram crowns","volume":"84","author":"Boening KW","year":"2000","journal-title":"J Prosthet Dent"},{"issue":"1","key":"e_1_2_9_16_1","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/j.jpor.2018.08.007","article-title":"Accuracy and retention of denture base fabricated by heat curing and additive manufacturing","volume":"63","author":"Tasaka A","year":"2019","journal-title":"J Prosthodont Res"},{"issue":"15","key":"e_1_2_9_17_1","doi-asserted-by":"crossref","first-page":"10212","DOI":"10.1021\/acs.chemrev.7b00074","article-title":"Polymers for 3D printing and customized additive manufacturing","volume":"117","author":"Ligon SC","year":"2017","journal-title":"Chem Rev"},{"key":"e_1_2_9_18_1","doi-asserted-by":"crossref","first-page":"429","DOI":"10.6028\/jres.119.017","article-title":"An additive manufacturing test artifact","volume":"119","author":"Moylan S","year":"2014","journal-title":"J Res Natl Inst Stan"},{"issue":"10","key":"e_1_2_9_19_1","doi-asserted-by":"crossref","first-page":"5987","DOI":"10.1007\/s00784-021-03905-9","article-title":"Influence of cleaning methods after 3D printing on two\u2010body wear and fracture load of resin\u2010based temporary crown and bridge material","volume":"25","author":"Mayer J","year":"2021","journal-title":"Clin Oral Investig"},{"issue":"5","key":"e_1_2_9_20_1","doi-asserted-by":"crossref","first-page":"e314","DOI":"10.1016\/j.dental.2021.01.016","article-title":"Effect of post\u2010rinsing time on the mechanical strength and cytotoxicity of a 3D printed orthodontic splint material","volume":"37","author":"Xu Y","year":"2021","journal-title":"Dent Mater"},{"issue":"7","key":"e_1_2_9_21_1","doi-asserted-by":"crossref","first-page":"610","DOI":"10.1111\/jopr.13288","article-title":"Influence of the rinsing postprocessing procedures on the manufacturing accuracy of vat\u2010polymerized dental model material","volume":"30","author":"Mostafavi D","year":"2021","journal-title":"J Prosthodont"},{"issue":"16","key":"e_1_2_9_22_1","doi-asserted-by":"crossref","first-page":"5329","DOI":"10.1016\/j.jeurceramsoc.2017.05.046","article-title":"Lithography\u2010based ceramic manufacturing (LCM)\u2014viscosity and cleaning as two quality influencing steps in the process chain of printing green parts","volume":"37","author":"Schwarzer E","year":"2017","journal-title":"J Eur Ceram Soc"},{"issue":"3","key":"e_1_2_9_23_1","doi-asserted-by":"crossref","first-page":"514","DOI":"10.1016\/j.prosdent.2019.02.024","article-title":"Assessment of the internal fit and marginal integrity of interim crowns made by different manufacturing methods","volume":"123","author":"Peng CC","year":"2020","journal-title":"J Prosthet Dent"},{"issue":"1","key":"e_1_2_9_24_1","doi-asserted-by":"crossref","first-page":"24","DOI":"10.4047\/jap.2021.13.1.24","article-title":"Effect of rinsing time on the accuracy of interim crowns fabricated by digital light processing: an in vitro study","volume":"13","author":"Lee BI","year":"2021","journal-title":"J Adv Prosthodont"},{"issue":"5","key":"e_1_2_9_25_1","doi-asserted-by":"crossref","first-page":"503","DOI":"10.11607\/ijp.4835","article-title":"Factors influencing the dimensional accuracy of 3D\u2010printed full\u2010coverage dental restorations using stereolithography technology","volume":"29","author":"Alharbi N","year":"2016","journal-title":"Int J Prosthodont"},{"issue":"2","key":"e_1_2_9_26_1","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1016\/j.jpor.2017.09.002","article-title":"Three\u2010dimensional evaluation of marginal and internal fit of 3D\u2010printed interim restorations fabricated on different finish line designs","volume":"62","author":"Alharbi N","year":"2018","journal-title":"J Prosthodont Res"},{"issue":"1","key":"e_1_2_9_27_1","doi-asserted-by":"crossref","first-page":"55","DOI":"10.4047\/jap.2019.11.1.55","article-title":"Comparing accuracy of denture bases fabricated by injection molding, CAD\/CAM milling, and rapid prototyping method","volume":"11","author":"Lee S","year":"2019","journal-title":"J Adv Prosthodont"},{"key":"e_1_2_9_28_1","doi-asserted-by":"crossref","DOI":"10.1016\/j.jmbbm.2020.103975","article-title":"Do hydrothermal aging and microwave sterilization affect the trueness of milled, additive manufactured and injection molded denture bases?","volume":"111","author":"Wemken G","year":"2020","journal-title":"J Mech Behav Biomed Mater"},{"key":"e_1_2_9_29_1","volume-title":"International solid freeform fabrication symposium","author":"Jacobs PF","year":"1991"},{"issue":"3","key":"e_1_2_9_30_1","doi-asserted-by":"crossref","first-page":"1576","DOI":"10.3390\/app12031576","article-title":"Accuracy of 3D\u2010printed occlusal devices of different volumes using a digital light processing printer","volume":"12","author":"Reich S","year":"2022","journal-title":"Appl Sci"},{"issue":"1","key":"e_1_2_9_31_1","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1111\/jopr.13122","article-title":"Assessment of the adaptation of interim crowns using different measurement techniques","volume":"29","author":"Peng CC","year":"2020","journal-title":"J Prosthodont"}],"container-title":["Journal of Prosthodontics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jopr.70011","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,25]],"date-time":"2025-07-25T03:35:07Z","timestamp":1753414507000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jopr.70011"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,24]]},"references-count":30,"alternative-id":["10.1111\/jopr.70011"],"URL":"https:\/\/doi.org\/10.1111\/jopr.70011","archive":["Portico"],"relation":{},"ISSN":["1059-941X","1532-849X"],"issn-type":[{"value":"1059-941X","type":"print"},{"value":"1532-849X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,24]]},"assertion":[{"value":"2025-03-20","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-07-07","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-07-24","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"jopr.70011"}}