{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T02:05:40Z","timestamp":1790820340140,"version":"4.1.0"},"reference-count":40,"publisher":"Wiley","license":[{"start":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T00:00:00Z","timestamp":1790726400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T00:00:00Z","timestamp":1790726400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Journal of Prosthodontics"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To evaluate the accuracy of wet and dry milled denture bases combined with printed or milled denture teeth.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods<\/jats:title>\n                    <jats:p>\n                      In this in vitro study, denture bases were manufactured using wet milled denture bases (Group I) dry milled denture bases (Group II). Teeth were milled by the same technique in Subgroup A in both groups, and they were printed in Subgroup B in both groups. All the dentures were scanned, and the data were imported to surface\u2010matching software to evaluate the accuracy of the teeth positions, the intaglio surfaces, as well as the overall accuracy of the denture. Statistical analysis was done using two\u2010way ANOVA for the accuracy of teeth positions and overall accuracy of the dentures, and unpaired\n                      <jats:italic>t<\/jats:italic>\n                      \u2010test for the accuracy of the intaglio surfaces. The significance level was set at\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0\u2264\u00a00.05.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Regarding the accuracy of teeth positions, the highest deviation (0.225\u00a0\u00b1\u00a00.0142\u00a0mm) was found in Group IIA (dry milled denture bases with dry milled teeth), whereas the least deviation (0.1332\u00a0\u00b1\u00a00.0236\u00a0mm) was found in Group IB (wet milled denture bases with printed teeth). On the other hand, regarding the accuracy of the intaglio surfaces, Group II (dry milled denture bases) showed more deviation (0.057175\u00a0\u00b1\u00a00.0111\u00a0mm) compared to Group I (wet milled denture bases) (0.043975\u00a0\u00b1\u00a00.009\u00a0mm). For the overall accuracy of the dentures, the highest deviation (0.1297\u00a0\u00b1\u00a00.0062\u00a0mm) was found in Group IIA (dry milled denture bases with dry milled teeth), whereas the least deviation (0.0937\u00a0\u00b1\u00a00.0132\u00a0mm) was found in Group IB (wet milled denture bases with printed teeth).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The most accurate teeth positions were obtained using printed teeth combined with wet milled denture bases. The most accurate intaglio surfaces were achieved using the wet milling technique. Overall accuracy was highest in dentures manufactured via wet milling of denture bases and 3D printing of denture teeth.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/jopr.70251","type":"journal-article","created":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T01:35:46Z","timestamp":1790818546000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Comparing the accuracy of wet and dry milled denture bases combined with printed and milled teeth"],"prefix":"10.1111","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-2667-7166","authenticated-orcid":false,"given":"Muhammad Amr","family":"Nabil","sequence":"first","affiliation":[{"name":"Oral and Maxillofacial Prosthodontics Department Faculty of Dentistry Ain Shams University  Cairo Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3244-0313","authenticated-orcid":false,"given":"Yasmine Galaleldin","family":"Thabet","sequence":"additional","affiliation":[{"name":"Oral and Maxillofacial Prosthodontics Department Faculty of Dentistry Ain Shams University  Cairo Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8407-5557","authenticated-orcid":false,"given":"Marwa Ezzat","family":"Sabet","sequence":"additional","affiliation":[{"name":"Oral and Maxillofacial Prosthodontics Department Faculty of Dentistry Ain Shams University  Cairo Egypt"},{"name":"Oral and Maxillofacial Prosthodontics Department Faculty of Dentistry British University  Cairo Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6237-0053","authenticated-orcid":false,"given":"Tarek Mohamed","family":"AL Sayed El Saaedi","sequence":"additional","affiliation":[{"name":"Oral and Maxillofacial Prosthodontics Department Faculty of Dentistry Ain Shams University  Cairo Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,9,30]]},"reference":[{"issue":"2","key":"e_1_2_8_2_1","doi-asserted-by":"crossref","first-page":"286","DOI":"10.4103\/1305-7456.178304","article-title":"A review of computer\u2010aided design\/computer\u2010aided manufacture techniques for removable denture fabrication","volume":"10","author":"Bilgin MS","year":"2016","journal-title":"Eur J Dent"},{"key":"e_1_2_8_3_1","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2024.105505","article-title":"Digital vs. conventional removable complete dentures: a retrospective study on clinical effectiveness and cost\u2010efficiency in edentulous patients","volume":"153","author":"Casucci A","year":"2025","journal-title":"J Dent"},{"issue":"1","key":"e_1_2_8_4_1","first-page":"45","article-title":"Preliminary investigation on the effect of cutting parameters on surface roughness and flatness in dry milling of PMMA","volume":"14","author":"Susac F","year":"2022","journal-title":"Int J Mod Manuf Technol"},{"issue":"1","key":"e_1_2_8_5_1","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1016\/j.prosdent.2017.02.009","article-title":"Comparison of denture tooth movement between CAD\u2013CAM and conventional fabrication techniques","volume":"119","author":"Goodacre BJ","year":"2018","journal-title":"J Prosthet Dent"},{"issue":"1","key":"e_1_2_8_6_1","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/j.prosdent.2021.04.028","article-title":"Assessment of tooth displacement during the cast\u2010free digital processing of milled dentures","volume":"129","author":"Lo Russo L","year":"2023","journal-title":"J Prosthet Dent"},{"issue":"3","key":"e_1_2_8_7_1","doi-asserted-by":"crossref","first-page":"889","DOI":"10.1055\/s-0042-1757211","article-title":"Fit accuracy of complete denture base fabricated by CAD\/CAM milling and 3D\u2010printing methods","volume":"17","author":"Charoenphol K","year":"2023","journal-title":"Eur J Dent"},{"issue":"2","key":"e_1_2_8_8_1","doi-asserted-by":"crossref","first-page":"422","DOI":"10.3390\/pr13020422","article-title":"Evolution and latest trends in cooling and lubrication techniques for sustainable machining: a systematic review","volume":"13","author":"Polo S","year":"2025","journal-title":"Processes"},{"key":"e_1_2_8_9_1","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/j.procir.2012.07.016","article-title":"Reduction of burr formation in drilling using cryogenic process cooling","volume":"3","author":"Biermann D","year":"2012","journal-title":"Procedia CIRP"},{"issue":"9","key":"e_1_2_8_10_1","doi-asserted-by":"crossref","first-page":"1466","DOI":"10.3390\/met12091466","article-title":"Green metalworking fluids for sustainable machining operations and other sustainable systems: a review","volume":"12","author":"Khan MAA","year":"2022","journal-title":"Metals"},{"key":"e_1_2_8_11_1","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/j.proeng.2017.04.075","article-title":"Technical, economic and environmental review of the lubrication\/cooling systems used in machining processes","volume":"184","author":"Benedicto E","year":"2017","journal-title":"Procedia Eng"},{"issue":"23","key":"e_1_2_8_12_1","doi-asserted-by":"crossref","first-page":"3985","DOI":"10.3390\/ma12233852","article-title":"Sustainable lubrication methods for the machining of titanium alloys: an overview","volume":"12","author":"Garc\u00eda\u2010Mart\u00ednez E","year":"2019","journal-title":"Materials"},{"issue":"2","key":"e_1_2_8_13_1","doi-asserted-by":"crossref","first-page":"417","DOI":"10.3390\/pr12020417","article-title":"Dry machining techniques for sustainability in metal cutting: a review","volume":"12","author":"Pawanr S","year":"2024","journal-title":"Processes"},{"key":"e_1_2_8_14_1","doi-asserted-by":"crossref","first-page":"1054","DOI":"10.1016\/j.promfg.2019.06.056","article-title":"A review of recent application of machining techniques, based on the phenomena of CNC machining operations","volume":"35","author":"Okokpujie IP","year":"2019","journal-title":"Procedia Manuf"},{"issue":"13","key":"e_1_2_8_15_1","doi-asserted-by":"crossref","first-page":"4693","DOI":"10.3390\/s22134693","article-title":"A comparative review of thermocouple and infrared radiation temperature measurement methods during the machining of metals","volume":"22","author":"Leonidas E","year":"2022","journal-title":"Sensors"},{"issue":"6","key":"e_1_2_8_16_1","doi-asserted-by":"crossref","first-page":"919","DOI":"10.1016\/j.prosdent.2018.01.027","article-title":"Evaluation of the trueness and tissue surface adaptation of CAD\u2013CAM mandibular denture bases manufactured using digital light processing","volume":"120","author":"Yoon HI","year":"2018","journal-title":"J Prosthet Dent"},{"issue":"4","key":"e_1_2_8_17_1","doi-asserted-by":"crossref","first-page":"469","DOI":"10.11607\/ijp.7193","article-title":"A comparison of denture base retention and adaptation between CAD\/CAM and conventional fabrication techniques","volume":"36","author":"Faty MA","year":"2023","journal-title":"Int J Prosthodont"},{"issue":"6","key":"e_1_2_8_18_1","doi-asserted-by":"crossref","first-page":"781","DOI":"10.11607\/ijp.7984","article-title":"Evaluation of accuracy and position of milled and 3D\u2010printed teeth in digital complete dentures","volume":"36","author":"Saaedi T","year":"2023","journal-title":"Int J Prosthodont"},{"issue":"1","key":"e_1_2_8_19_1","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1111\/j.1365-2842.1993.tb01511.x","article-title":"Posterior palatal seal adaptation: influence of processing technique, palate shape and immersion","volume":"20","author":"Sykora O","year":"1993","journal-title":"J Oral Rehabil"},{"issue":"6","key":"e_1_2_8_20_1","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1016\/j.prosdent.2013.07.005","article-title":"Three\u2010dimensional processing deformation of three denture base materials","volume":"110","author":"Artopoulos A","year":"2013","journal-title":"J Prosthet Dent"},{"issue":"8","key":"e_1_2_8_21_1","doi-asserted-by":"crossref","first-page":"808","DOI":"10.1111\/jopr.13769","article-title":"Assessment of tooth positions of printed complete dentures with different designs and tooth positioning techniques","volume":"33","author":"Thabet YG","year":"2024","journal-title":"J Prosthodont"},{"issue":"2","key":"e_1_2_8_22_1","doi-asserted-by":"crossref","first-page":"464","DOI":"10.1016\/j.identj.2024.11.007","article-title":"Are there clinical differences between 3D\u2010printed and milled complete dentures? A systematic review and meta\u2010analysis","volume":"75","author":"Khorasani E","year":"2025","journal-title":"Int Dent J"},{"issue":"2","key":"e_1_2_8_23_1","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/j.prosdent.2016.02.017","article-title":"Comparison of denture base adaptation between CAD\u2013CAM and conventional fabrication techniques","volume":"116","author":"Goodacre BJ","year":"2016","journal-title":"J Prosthet Dent"},{"key":"e_1_2_8_24_1","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2021.103777","article-title":"CAD\u2013CAM removable complete dentures: a systematic review and meta\u2010analysis of trueness of fit, biocompatibility, mechanical properties, surface characteristics, color stability, time\u2010cost analysis, clinical and patient\u2010reported outcomes","volume":"113","author":"Srinivasan M","year":"2021","journal-title":"J Dent"},{"issue":"5","key":"e_1_2_8_25_1","doi-asserted-by":"crossref","DOI":"10.1016\/j.heliyon.2024.e26874","article-title":"Trueness of five different 3D printing systems including budget\u2010 and professional\u2010grade printers: an in vitro study","volume":"10","author":"Palaszk\u00f3 D","year":"2024","journal-title":"Heliyon"},{"key":"e_1_2_8_26_1","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2025.106110","article-title":"Occlusal accuracy of digitally manufactured removable dentures: a systematic review of in vitro studies","volume":"162","author":"Wang X","year":"2025","journal-title":"J Dent"},{"issue":"4","key":"e_1_2_8_27_1","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1111\/jopr.13033","article-title":"A comparison of the surface properties of CAD\/CAM and conventional polymethylmethacrylate (PMMA)","volume":"28","author":"Al\u2010Dwairi ZN","year":"2019","journal-title":"J Prosthodont"},{"issue":"1","key":"e_1_2_8_28_1","doi-asserted-by":"crossref","first-page":"126","DOI":"10.4103\/jispcd.JISPCD_293_21","article-title":"In\u2010vitro comparative evaluation for the surface properties and impact strength of CAD\/CAM milled, 3D printed, and polyamide denture base resins","volume":"12","author":"Helal MA","year":"2022","journal-title":"J Int Soc Prev Community Dent"},{"issue":"4","key":"e_1_2_8_29_1","doi-asserted-by":"crossref","first-page":"623","DOI":"10.2186\/jpr.JPR_D_21_00048","article-title":"Patient satisfaction with conventional dentures vs. digital dentures fabricated using 3D\u2010printing: a randomized crossover trial","volume":"66","author":"Ohara K","year":"2022","journal-title":"J Prosthodont Res"},{"issue":"2","key":"e_1_2_8_30_1","doi-asserted-by":"crossref","first-page":"532","DOI":"10.3390\/jcm9020324","article-title":"Eighteen months follow\u2010up with patient\u2010centered outcomes assessment of complete dentures manufactured using a hybrid nanocomposite and additive CAD\/CAM protocol","volume":"9","author":"Cristache CM","year":"2020","journal-title":"J Clin Med"},{"issue":"1","key":"e_1_2_8_31_1","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1186\/s12903-024-03851-4","article-title":"Build angle effect on 3D\u2010printed dental crowns marginal fit using digital light\u2010processing and stereo\u2010lithography technology: an in vitro study","volume":"24","author":"Farag E","year":"2024","journal-title":"BMC Oral Health"},{"key":"e_1_2_8_32_1","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2021.103842","article-title":"CAD\u2013CAM complete removable dental prostheses: a double\u2010blind, randomized, crossover clinical trial evaluating milled and 3D\u2010printed dentures","volume":"115","author":"Srinivasan M","year":"2021","journal-title":"J Dent"},{"issue":"9","key":"e_1_2_8_33_1","first-page":"733","article-title":"Current challenges for 3D printing complete dentures: experiences from a multi\u2010centre clinical trial","volume":"235","author":"Osnes C","year":"2023","journal-title":"Br Dent J"},{"issue":"7","key":"e_1_2_8_34_1","first-page":"205","article-title":"Impact of printing orientation on the accuracy of additively fabricated denture base materials: a systematic review","volume":"12","author":"AlGhamdi MA","year":"2024","journal-title":"Dent J (Basel)"},{"issue":"4","key":"e_1_2_8_35_1","doi-asserted-by":"crossref","first-page":"641","DOI":"10.2186\/jpr.JPR_D_22_00245","article-title":"Effects of build orientation and bar addition on accuracy of complete denture base fabricated with digital light projection: an in vitro study","volume":"67","author":"Chaiamornsup P","year":"2023","journal-title":"J Prosthodont Res"},{"issue":"4","key":"e_1_2_8_36_1","doi-asserted-by":"crossref","first-page":"559","DOI":"10.2186\/jpr.JPR_D_20_00240","article-title":"Trueness and fitting accuracy of maxillary 3D printed complete dentures","volume":"65","author":"Yoshidome K","year":"2021","journal-title":"J Prosthodont Res"},{"key":"e_1_2_8_37_1","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2021.103924","article-title":"The occlusal precision of milled versus printed provisional crowns","volume":"117","author":"Giannetti L","year":"2022","journal-title":"J Dent"},{"issue":"1","key":"e_1_2_8_38_1","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/j.prosdent.2021.04.028","article-title":"Assessment of tooth displacement during the cast\u2010free digital processing of milled dentures","volume":"129","author":"Park JM","year":"2023","journal-title":"J Prosthet Dent"},{"issue":"2","key":"e_1_2_8_39_1","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1111\/adj.12817","article-title":"Comparison of artificial tooth position in dentures fabricated by heat curing and additive manufacturing","volume":"66","author":"Tasaka A","year":"2021","journal-title":"Aust Dent J"},{"issue":"2","key":"e_1_2_8_40_1","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1111\/jopr.13245","article-title":"Effect of milling protocols on trueness and precision of ceramic crowns","volume":"30","author":"Al Hamad KQ","year":"2021","journal-title":"J Prosthodont"},{"issue":"8","key":"e_1_2_8_41_1","doi-asserted-by":"crossref","first-page":"2829","DOI":"10.1007\/s00784-018-2369-2","article-title":"CAD\/CAM produces dentures with improved fit","volume":"22","author":"Steinmassl O","year":"2018","journal-title":"Clin Oral Investig"}],"container-title":["Journal of Prosthodontics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jopr.70251","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/jopr.70251","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jopr.70251","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T01:35:50Z","timestamp":1790818550000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jopr.70251"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,30]]},"references-count":40,"alternative-id":["10.1111\/jopr.70251"],"URL":"https:\/\/doi.org\/10.1111\/jopr.70251","archive":["Portico"],"relation":{},"ISSN":["1059-941X","1532-849X"],"issn-type":[{"value":"1059-941X","type":"print"},{"value":"1532-849X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,30]]},"assertion":[{"value":"2025-12-23","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-09-16","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-09-30","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"jopr.70251"}}