{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T10:52:39Z","timestamp":1791456759367,"version":"4.3.4"},"reference-count":26,"publisher":"Wiley","license":[{"start":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T00:00:00Z","timestamp":1791417600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T00:00:00Z","timestamp":1791417600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Journal of Prosthodontics"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Complications in fixed implant prostheses are frequently encountered and can negatively impact patients' quality of life. This technique outlines a complete digital workflow for the remake of full\u2010mouth, implant\u2010supported, cement\u2010retained restorations necessitated by esthetic and functional impairments. For the digital recording of reused abutments, a contemporary technique was employed in which extraorally scanned abutment data were digitally superimposed onto their corresponding counterparts in the intraoral scans. The jaw relation record procedures were completed in stages. Initially, centric relation was recorded using a graphic recording technique with a gothic arch tracer. This was followed by capturing mandibular movements under anterior guidance as real movement data using the Jaw Motion Analyzer (Zebris). Based on these digital records, the definitive prostheses were designed and delivered. Follow\u2010up was conducted at six months to evaluate clinical outcomes.<\/jats:p>","DOI":"10.1111\/jopr.70255","type":"journal-article","created":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T10:13:03Z","timestamp":1791454383000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["An innovative approach for retreatment of prosthetically failing implant\u2010supported fixed prostheses with a complete digital workflow: A technique report"],"prefix":"10.1111","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7015-7324","authenticated-orcid":false,"given":"Sinem Kahya","family":"Karaca","sequence":"first","affiliation":[{"name":"Department of Prosthodontics Faculty of Dentistry, Hacettepe University  Ankara Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3817-0729","authenticated-orcid":false,"given":"Fatmanur Demir","family":"Boz","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics Faculty of Dentistry, Hacettepe University  Ankara Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3013-2533","authenticated-orcid":false,"given":"K\u0131van\u00e7","family":"Ak\u00e7a","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics Faculty of Dentistry, Hacettepe University  Ankara Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,10,8]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"crossref","first-page":"256","DOI":"10.11607\/jomi.2014suppl.g4.3","article-title":"Implant loading protocols for edentulous patients with fixed prostheses: a systematic review and meta\u2010analysis","volume":"29","author":"Papaspyridakos P","year":"2014","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_7_3_1","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1016\/j.joms.2009.07.007","article-title":"Fixed rehabilitation of the edentulous maxilla: possibilities and clinical outcome","volume":"67","author":"Att W","year":"2009","journal-title":"J Oral Maxillofac Surg"},{"key":"e_1_2_7_4_1","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1111\/j.1708-8208.2007.00081.x","article-title":"Implant treatment of patients with edentulous jaws: a 20\u2010year follow\u2010up","volume":"10","author":"\u00c5strand P","year":"2008","journal-title":"Clin Implant Dent Relat Res"},{"key":"e_1_2_7_5_1","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1111\/j.1600-0501.2008.01699.x","article-title":"Five\u2010year results of fixed implant\u2010supported rehabilitations with distal cantilevers for the edentulous mandible","volume":"20","author":"Gallucci GO","year":"2009","journal-title":"Clin Oral Implants Res"},{"key":"e_1_2_7_6_1","first-page":"102","article-title":"A systematic review of biologic and technical complications with fixed implant rehabilitations for edentulous patients","volume":"27","author":"Papaspyridakos P","year":"2012","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_7_7_1","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/S0022-3913(03)00212-9","article-title":"Clinical complications with implants and implant prostheses","volume":"90","author":"Goodacre CJ","year":"2003","journal-title":"J Prosthet Dent"},{"key":"e_1_2_7_8_1","volume-title":"Biological and hardware complications in implant dentistry","author":"Wismeijer D","year":"2015"},{"key":"e_1_2_7_9_1","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1111\/jopr.13119","article-title":"Technical complications and prosthesis survival rates with implant\u2010supported fixed complete dental prostheses: a retrospective study with 1\u2010 to 12\u2010year follow\u2010up","volume":"29","author":"Papaspyridakos P","year":"2020","journal-title":"J Prosthodont"},{"key":"e_1_2_7_10_1","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2022.104365","article-title":"Occlusal adjustment of 3\u2010unit tooth\u2010supported fixed dental prostheses fabricated with complete\u2010digital and\u2010analog workflows: a crossover clinical trial","volume":"128","author":"Karasan D","year":"2023","journal-title":"J Dent"},{"key":"e_1_2_7_11_1","doi-asserted-by":"crossref","first-page":"1208","DOI":"10.1016\/j.prosdent.2022.03.008","article-title":"Effect of custom abutment data superimposition on the accuracy of implant abutment level scanning: an in vitro study","volume":"131","author":"Baek YW","year":"2024","journal-title":"J Prosthet Dent"},{"key":"e_1_2_7_12_1","doi-asserted-by":"crossref","first-page":"390","DOI":"10.11607\/ijp.7357","article-title":"Accuracy of customized abutment data superimposition according to the extent of scanning area","volume":"34","author":"Park TM","year":"2021","journal-title":"Int J Prosthodont"},{"key":"e_1_2_7_13_1","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1016\/j.prosdent.2019.11.003","article-title":"Cordless digital workflow for scanning implant\u2010supported prostheses at the abutment level: a dental technique","volume":"124","author":"Cho WT","year":"2020","journal-title":"J Prosthet Dent"},{"key":"e_1_2_7_14_1","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1016\/j.prosdent.2016.10.025","article-title":"Simplified digital workflow for dental implant restoration on a stock abutment using an intraoral scanner: a dental technique","volume":"118","author":"Kim JE","year":"2017","journal-title":"J Prosthet Dent"},{"key":"e_1_2_7_15_1","doi-asserted-by":"crossref","first-page":"752","DOI":"10.11607\/ijp.6959","article-title":"Evaluation of the clinical accuracy of implant abutment\u2010level impression technique using digital superimposition of customized abutment","volume":"34","author":"Kim JW","year":"2021","journal-title":"Int J Prosthodont"},{"key":"e_1_2_7_16_1","doi-asserted-by":"crossref","first-page":"1454","DOI":"10.1186\/s12903-024-05271-w","article-title":"Replacement of a single\u2010tooth implant restoration with the abutment dual\u2010scanning technique: a case report","volume":"24","author":"Boz FD","year":"2024","journal-title":"BMC Oral Health"},{"key":"e_1_2_7_17_1","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1111\/jcpe.12956","article-title":"Peri\u2010implant health, peri\u2010implant mucositis, and peri\u2010implantitis: case definitions and diagnostic considerations","volume":"45","author":"Renvert S","year":"2018","journal-title":"J Clin Periodontol"},{"key":"e_1_2_7_18_1","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1111\/jcpe.12957","article-title":"Peri\u2010implant diseases and conditions: consensus report of workgroup 4 of the 2017 World Workshop on the Classification of Periodontal and Peri\u2010Implant Diseases and Conditions","volume":"45","author":"Berglundh T","year":"2018","journal-title":"J Clin Periodontol"},{"key":"e_1_2_7_19_1","volume-title":"Functional occlusion: from TMJ to smile design","author":"Dawson PE","year":"2006"},{"key":"e_1_2_7_20_1","doi-asserted-by":"crossref","first-page":"771","DOI":"10.1111\/cid.12170","article-title":"Clinical factors influencing removal of the cement excess in implant\u2010supported restorations","volume":"17","author":"Vindasuite E","year":"2015","journal-title":"Clin. Implant Dent Relat Res"},{"key":"e_1_2_7_21_1","doi-asserted-by":"crossref","first-page":"562","DOI":"10.2186\/jpr.JPR_D_24_00303","article-title":"Digital occlusal analysis of bite registration with anteroposterior inclined head positions","volume":"69","author":"Kahya S","year":"2025","journal-title":"J Prosthodont Res"},{"key":"e_1_2_7_22_1","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1016\/j.prosdent.2013.06.026","article-title":"A technique to eliminate subgingival cement adhesion to implant abutments by using polytetrafluoroethylene tape","volume":"112","author":"Hess TA","year":"2014","journal-title":"J Prosthet Dent"},{"key":"e_1_2_7_23_1","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/S0022-3913(97)70086-6","article-title":"Cement removal from restorations luted to titanium abutments with simulated subgingival margins","volume":"78","author":"Agar JR","year":"1997","journal-title":"J Prosthet Dent"},{"key":"e_1_2_7_24_1","unstructured":"ChenJ YangD ZhouH BuckleyS. Avoiding spurious reflections from shiny surfaces on a 3D real\u2010time machine vision inspection system. In:IMTC\/98 conference proceedings. IEEE instrumentation and measurement technology conference. Where instrumentation is going (Cat.No.98CH36222). St. Paul MN: IEEE; 1998. p.364\u20138."},{"key":"e_1_2_7_25_1","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1117\/1.601014","article-title":"Reflection properties of machined metal surfaces","volume":"35","author":"Kierkegaard P","year":"1996","journal-title":"Opt Eng"},{"key":"e_1_2_7_26_1","doi-asserted-by":"crossref","first-page":"3","DOI":"10.4103\/0975-5950.168233","article-title":"Technical complications of implant\u2010causes and management: a comprehensive review","volume":"6","author":"Gupta S","year":"2015","journal-title":"Natl J Maxillofac Surg"},{"key":"e_1_2_7_27_1","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1111\/clr.13277","article-title":"A systematic review of the survival and complication rates of zirconia\u2010ceramic and metal\u2010ceramic multiple\u2010unit fixed dental prostheses","volume":"29","author":"Sailer I","year":"2018","journal-title":"Clin Oral Implants Res"}],"container-title":["Journal of Prosthodontics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jopr.70255","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/jopr.70255","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jopr.70255","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T10:13:08Z","timestamp":1791454388000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jopr.70255"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,8]]},"references-count":26,"alternative-id":["10.1111\/jopr.70255"],"URL":"https:\/\/doi.org\/10.1111\/jopr.70255","archive":["Portico"],"relation":{},"ISSN":["1059-941X","1532-849X"],"issn-type":[{"value":"1059-941X","type":"print"},{"value":"1532-849X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,8]]},"assertion":[{"value":"2026-04-16","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-09-21","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-10-08","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"jopr.70255"}}