{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,13]],"date-time":"2026-07-13T06:05:47Z","timestamp":1783922747999,"version":"3.55.0"},"reference-count":20,"publisher":"Wiley","license":[{"start":{"date-parts":[[2026,7,12]],"date-time":"2026-07-12T00:00:00Z","timestamp":1783814400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,7,12]],"date-time":"2026-07-12T00:00:00Z","timestamp":1783814400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J of Small Animal Practice"],"abstract":"<jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>The objective of the study was to evaluate agreement between tongue\u2010based oscillometric and invasive arterial blood pressure in anaesthetised dogs, assess performance against American College of Veterinary Internal Medicine and Association for the Advancement of Medical Instrumentation\/European Society of Hypertension\/International Organization for Standardization validation criteria and examine proportional bias overall and by body size and phenotype.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods<\/jats:title>\n                    <jats:p>\n                      Prospective observational study of 89 client\u2010owned dogs undergoing general anaesthesia. Simultaneous tongue\u2010based oscillometric and invasive arterial systolic, mean and diastolic pressures were recorded at 5\u2010minute intervals (1780 paired observations). Agreement was assessed using Bland\u2013Altman analysis and performance judged against American College of\u00a0Veterinary Internal Medicine and Association for the Advancement of Medical Instrumentation\/European Society of Hypertension\/International Organization for Standardization criteria. Proportional bias (difference vs. mean pressure) was evaluated with linear mixed\u2010effects models with dogs as a random effect, with body size (\u226410\u2009kg\n                      <jats:italic>vs.<\/jats:italic>\n                      &gt;10\u2009kg) and phenotype (chondrodystrophic\n                      <jats:italic>vs.<\/jats:italic>\n                      non\u2010chondrodystrophic) as interaction terms.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>American College of Veterinary Internal Medicine criteria were met for mean and diastolic but not systolic pressure; no measure met Association for the Advancement of Medical Instrumentation\/European Society of Hypertension\/International Organization for Standardization thresholds. Limits of agreement for mean and diastolic pressures were wide. Systolic pressure showed magnitude\u2010dependent underestimation, whereas mean and diastolic pressures did not. Underestimation increased with systolic pressure in dogs &gt;10\u2009kg and in non\u2010chondrodystrophic dogs, whereas no clear pressure\u2010dependent trend was seen in dogs \u226410\u2009kg or in chondrodystrophic dogs. Transient tongue swelling occurred in one\u00a0dog; no other tongue\u2010related adverse events were recorded.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical Significance<\/jats:title>\n                    <jats:p>Tongue\u2010based oscillometry achieved acceptable agreement for mean and diastolic arterial pressures according to American College of Veterinary Internal Medicine criteria but did not meet Association for the Advancement of Medical Instrumentation\/European Society of Hypertension\/International Organization for Standardization validation standards. However, limits of agreement remained wide, and tongue\u2010based oscillometric blood pressure should be interpreted cautiously and in conjunction with clinical context, rather than as a direct substitute for invasive blood pressure measurements. When invasive monitoring is unavailable, it remains useful for following trends in mean and diastolic pressure. Systolic values should be interpreted cautiously, particularly at higher pressures in dogs &gt;10\u2009kg or non\u2010chondrodystrophic dogs.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/jsap.70163","type":"journal-article","created":{"date-parts":[[2026,7,13]],"date-time":"2026-07-13T05:14:12Z","timestamp":1783919652000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of lingual oscillometric and invasive blood pressure measurement in dogs under general anaesthesia"],"prefix":"10.1111","author":[{"ORCID":"https:\/\/orcid.org\/0009-0006-4370-9396","authenticated-orcid":false,"given":"C.","family":"Kyle","sequence":"first","affiliation":[{"name":"Langford Vets University of Bristol  Langford Bristol BS40 5DU UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Deutsch","sequence":"additional","affiliation":[{"name":"Langford Vets University of Bristol  Langford Bristol BS40 5DU UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,7,12]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"crossref","first-page":"582","DOI":"10.1016\/j.rvsc.2014.10.004","article-title":"Comparison between invasive blood pressure and a non\u2010invasive blood pressure monitor in anesthetized sheep","volume":"97","author":"Almeida D.","year":"2014","journal-title":"Research in Veterinary Science"},{"key":"e_1_2_7_3_1","doi-asserted-by":"crossref","first-page":"542","DOI":"10.1111\/j.1939-1676.2007.tb03005.x","article-title":"Guidelines for the identification, evaluation, and management of systemic hypertension in dogs and cats","volume":"21","author":"Brown S.","year":"2007","journal-title":"Journal of Veterinary Internal Medicine"},{"key":"e_1_2_7_4_1","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1111\/j.1467-2995.2012.00711.x","article-title":"Agreement between direct, oscillometric and Doppler ultrasound blood pressures using three different cuff positions in anesthetized dogs","volume":"39","author":"Garofalo N.A.","year":"2012","journal-title":"Veterinary Anaesthesia and Analgesia"},{"key":"e_1_2_7_5_1","doi-asserted-by":"crossref","first-page":"59","DOI":"10.5326\/JAAHA-MS-7055","article-title":"2020 AAHA anesthesia and monitoring guidelines for dogs and cats","volume":"56","author":"Grubb T.","year":"2020","journal-title":"Journal of the American Animal Hospital Association"},{"key":"e_1_2_7_6_1","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1016\/j.vaa.2021.11.003","article-title":"Evaluation of the tongue for oscillometric measurement of arterial pressure in anesthetized beagle dogs","volume":"49","author":"Kim D.","year":"2022","journal-title":"Veterinary Anaesthesia and Analgesia"},{"key":"e_1_2_7_7_1","doi-asserted-by":"crossref","first-page":"136","DOI":"10.5326\/JAAHA-MS-7325","article-title":"Agreement between tongue\u2010based oscillometric and invasive blood pressure in anesthetized dogs of various weights","volume":"59","author":"Kim D.","year":"2023","journal-title":"Journal of the American Animal Hospital Association"},{"key":"e_1_2_7_8_1","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1007\/s11259-010-9346-9","article-title":"Comparison of invasive and non\u2010invasive blood pressure monitoring during clinical anaesthesia in dogs","volume":"34","author":"MacFarlane P.","year":"2010","journal-title":"Veterinary Research Communications"},{"key":"e_1_2_7_9_1","doi-asserted-by":"crossref","first-page":"482","DOI":"10.1016\/j.vaa.2024.06.013","article-title":"Evaluation of lingual oscillometric blood pressure measurement in anaesthetized pigs","volume":"51","author":"Makepeace C.","year":"2024","journal-title":"Veterinary Anaesthesia and Analgesia"},{"key":"e_1_2_7_10_1","doi-asserted-by":"crossref","first-page":"1541","DOI":"10.2460\/ajvr.67.9.1541","article-title":"Accuracy of an oscillometric blood pressure monitor during phenylephrine\u2010induced hypertension in dogs","volume":"67","author":"McMurphy R.","year":"2006","journal-title":"American Journal of Veterinary Research"},{"key":"e_1_2_7_11_1","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1007\/s10877-024-01152-3","article-title":"Towards the automatic detection and correction of abnormal arterial pressure waveforms","volume":"38","author":"Michard F.","year":"2024","journal-title":"Journal of Clinical Monitoring and Computing"},{"key":"e_1_2_7_12_1","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.vaa.2023.08.007","article-title":"Evaluation of the agreement between lingual and thoracic limb noninvasive blood pressure with invasive blood pressure measurements in anaesthetized horses","volume":"51","author":"Parra Martinez C.","year":"2024","journal-title":"Veterinary Anaesthesia and Analgesia"},{"key":"e_1_2_7_13_1","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1111\/vaa.12169","article-title":"What is the definition of intraoperative hypotension in dogs? Results from a survey of diplomates of the ACVAA and ECVAA","volume":"42","author":"Ruffato M.","year":"2015","journal-title":"Veterinary Anaesthesia and Analgesia"},{"key":"e_1_2_7_14_1","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1111\/vaa.12035","article-title":"A clinical comparison between a non\u2010invasive blood pressure monitor using high definition oscillometry (memodiagnostic MD 15\/90 pro) and invasive arterial blood pressure measurement in anaesthetized dogs","volume":"40","author":"Rysnik M.K.","year":"2013","journal-title":"Veterinary Anaesthesia and Analgesia"},{"key":"e_1_2_7_15_1","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1111\/j.1467-2995.2004.00141.x","article-title":"Evaluation of a new oscillometric blood pressure monitor in isoflurane\u2010anesthetized dogs","volume":"31","author":"Sawyer D.","year":"2004","journal-title":"Veterinary Anaesthesia and Analgesia"},{"key":"e_1_2_7_16_1","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1186\/cc1489","article-title":"Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine","volume":"6","author":"Scheer B.","year":"2002","journal-title":"Critical Care"},{"key":"e_1_2_7_17_1","first-page":"368","article-title":"Non\u2010invasive blood pressure measurement in animals: part 1 \u2013 techniques for measurement and validation of non\u2010invasive devices","volume":"61","author":"Skelding A.","year":"2020","journal-title":"Canadian Veterinary Journal"},{"key":"e_1_2_7_18_1","doi-asserted-by":"crossref","first-page":"472","DOI":"10.1097\/HJH.0000000000001634","article-title":"A universal standard for the validation of blood pressure measuring devices: Association for the Advancement of Medical Instrumentation\/European Society of Hypertension\/International Organization for Standardization (AAMI\/ESH\/ISO) collaboration statement","volume":"36","author":"Stergiou G.","year":"2018","journal-title":"Journal of Hypertension"},{"key":"e_1_2_7_19_1","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1016\/j.rvsc.2014.05.003","article-title":"Evaluation of oscillometric and Doppler ultrasonic devices for blood pressure measurements in anesthetized and conscious dogs","volume":"97","author":"Vachon C.","year":"2014","journal-title":"Research in Veterinary Science"},{"key":"e_1_2_7_20_1","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1016\/S0034-5288(18)34303-0","article-title":"The effect of cuff width on accuracy of indirect measurement of blood pressure in dogs","volume":"11","author":"Valtonen M.G.","year":"1970","journal-title":"Research in Veterinary Science"},{"key":"e_1_2_7_21_1","doi-asserted-by":"crossref","DOI":"10.3390\/vetsci12040349","article-title":"Evaluation of two veterinary oscillometric noninvasive blood pressure (NIBP) measurement devices (petMAP graphic II and high\u2010definition oscillometry) in dogs","volume":"12","author":"Walter H.","year":"2025","journal-title":"Veterinary Sciences"}],"container-title":["Journal of Small Animal Practice"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jsap.70163","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/jsap.70163","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jsap.70163","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,13]],"date-time":"2026-07-13T05:14:14Z","timestamp":1783919654000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jsap.70163"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,12]]},"references-count":20,"alternative-id":["10.1111\/jsap.70163"],"URL":"https:\/\/doi.org\/10.1111\/jsap.70163","archive":["Portico"],"relation":{},"ISSN":["0022-4510","1748-5827"],"issn-type":[{"value":"0022-4510","type":"print"},{"value":"1748-5827","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,12]]},"assertion":[{"value":"2026-01-19","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-06-24","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-07-12","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"jsap.70163"}}