{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T05:06:07Z","timestamp":1784264767959,"version":"3.55.0"},"reference-count":37,"publisher":"Wiley","license":[{"start":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T00:00:00Z","timestamp":1784160000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"},{"start":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T00:00:00Z","timestamp":1784160000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Journal of Sleep Research"],"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:p>\n                    Accurate peripheral blood oxygen saturation (SpO\n                    <jats:sub>2<\/jats:sub>\n                    ) measurements are critical for evaluating sleep patients, particularly those with frequent desaturations due to pathological breathing events. We compared synchronised SpO\n                    <jats:sub>2<\/jats:sub>\n                    measurements obtained from three anatomical sites (finger, forehead and toe) in patients undergoing routine Type 1 polysomnography (PSG) to assess site\u2010related variability. Continuous and simultaneous pulse oximetry recordings from 41 sleep patients were synchronised with PSG data and scored for SpO\n                    <jats:sub>2<\/jats:sub>\n                    desaturations (\u2265\u20093% and \u2265\u200910\u2009s), signal dropouts and artefact occurrences. Forehead and toe SpO\n                    <jats:sub>2<\/jats:sub>\n                    measurements were compared against finger oximetry, the standard PSG oximetry site. Significant differences were observed between anatomical sites for mean SpO\n                    <jats:sub>2<\/jats:sub>\n                    (\n                    <jats:italic>p\u2009&lt;<\/jats:italic>\n                    \u20090.01), mean SpO\n                    <jats:sub>2<\/jats:sub>\n                    desaturations per hour (\n                    <jats:italic>p\u2009&lt;<\/jats:italic>\n                    \u20090.01) and time spent below an SpO\n                    <jats:sub>2<\/jats:sub>\n                    level of 95% during total sleep time (\n                    <jats:italic>p<\/jats:italic>\n                    \u2009&lt;\u20090.01). Forehead pulse oximetry demonstrated the highest mean SpO\n                    <jats:sub>2<\/jats:sub>\n                    , the fewest SpO\n                    <jats:sub>2<\/jats:sub>\n                    desaturations per hour and the least artefact occurrences (\n                    <jats:italic>p<\/jats:italic>\n                    \u2009=\u20090.024), while finger oximetry exhibited the most signal dropouts (\n                    <jats:italic>p\u2009&lt;<\/jats:italic>\n                    \u20090.01). Finger and toe pulse oximetry showed the strongest concordance for SpO\n                    <jats:sub>2<\/jats:sub>\n                    desaturations per hour (\n                    <jats:italic>r<\/jats:italic>\n                    \u2009=\u20090.948). Observed differences in SpO\n                    <jats:sub>2<\/jats:sub>\n                    measurements are likely due to perfusion variability between peripheral and core circulation during sudden blood pressure oscillations associated with sleep disordered breathing. Our findings highlight that anatomical site choice for measuring SpO\n                    <jats:sub>2<\/jats:sub>\n                    during PSG may have significant implications in the severity classification, diagnosis and treatment of sleep disorders; especially for limited channel sleep studies that rely primarily on oximetry. Further research is required to determine which anatomical site reflects true arterial oxygenation in sleep patients.\n                  <\/jats:p>","DOI":"10.1111\/jsr.70400","type":"journal-article","created":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T04:21:29Z","timestamp":1784262089000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Does Measurement Site Matter? A Comparison Between Finger, Forehead, and Toe Pulse Oximetry Measurements in Polysomnography"],"prefix":"10.1111","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8397-6003","authenticated-orcid":false,"given":"Kellie R.","family":"Strickland","sequence":"first","affiliation":[{"name":"School of Science, Technology and Engineering University of the Sunshine Coast  Sippy Downs Queensland Australia"},{"name":"Sunshine Coast Health Institute  Birtinya Queensland Australia"},{"name":"Sunshine Coast Hospital and Health Service  Birtinya Queensland Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chris J.","family":"Brown","sequence":"additional","affiliation":[{"name":"Sunshine Coast Hospital and Health Service  Birtinya Queensland Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leigh","family":"Wilks","sequence":"additional","affiliation":[{"name":"Sunshine Coast Health Institute  Birtinya Queensland Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0299-7169","authenticated-orcid":false,"given":"Peter K.","family":"Dunn","sequence":"additional","affiliation":[{"name":"School of Science, Technology and Engineering University of the Sunshine Coast  Sippy Downs Queensland Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark A.","family":"Holmes","sequence":"additional","affiliation":[{"name":"School of Health University of the Sunshine Coast  Sippy Downs Queensland Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,7,16]]},"reference":[{"key":"e_1_2_12_2_1","doi-asserted-by":"crossref","first-page":"423","DOI":"10.4187\/respcare.04435","article-title":"Pulse Oximetry Overestimates Oxygen Saturation in COPD","volume":"61","author":"Amalakanti S.","year":"2016","journal-title":"Respiratory Care"},{"key":"e_1_2_12_3_1","doi-asserted-by":"crossref","first-page":"2359","DOI":"10.1152\/jappl.2001.91.5.2359","article-title":"Peripheral Vascular Resistance Increases After Termination of Obstructive Apnoeas","volume":"91","author":"Anand A.","year":"2001","journal-title":"Journal of Applied Physiology"},{"key":"e_1_2_12_4_1","volume-title":"ASTA\/ASA Commentary on AASM Manual for the Scoring of Sleep and Associated Events","author":"Australasian Sleep Technologists Association\/Australasian Sleep Association","year":"2010"},{"key":"e_1_2_12_5_1","first-page":"22","article-title":"Effect of Recording Site on Pulse Oximetry Readings","volume":"108","author":"Bedab R.","year":"2012","journal-title":"Nursing Times"},{"key":"e_1_2_12_6_1","volume-title":"The AASM Manual for the Scoring of Sleep and Associated Events: Rules, Terminology and Technical Specifications","author":"Berry R.","year":"2018"},{"key":"e_1_2_12_7_1","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical Methods for Assessing Agreement Between Two Methods of Clinical Measurement","volume":"8","author":"Bland J. M.","year":"1986","journal-title":"Lancet"},{"key":"e_1_2_12_8_1","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1016\/j.jopan.2008.07.009","article-title":"Comparison of Finger and Forehead Oximetry Sensors in Postanesthesia Care Patients","volume":"23","author":"Blaylock V.","year":"2008","journal-title":"Journal of Perianesthesia Nursing"},{"key":"e_1_2_12_9_1","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1183\/09031936.97.10020446","article-title":"Comparison of Invasive and Noninvasive Saturation Monitoring in Prescribing Oxygen During Exercise in COPD Patients","volume":"10","author":"Carone M.","year":"1997","journal-title":"European Respiratory Journal"},{"key":"e_1_2_12_10_1","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1016\/j.rmed.2013.02.004","article-title":"Pulse Oximetry: Understanding Its Basic Principles Facilitates Appreciation of Its Limitations","volume":"107","author":"Chan E.","year":"2013","journal-title":"Respiratory Medicine"},{"key":"e_1_2_12_11_1","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1152\/physrev.00043.2008","article-title":"Pathophysiology of Sleep Apnoea","volume":"90","author":"Dempsey J.","year":"2010","journal-title":"Physiological Reviews"},{"key":"e_1_2_12_12_1","doi-asserted-by":"crossref","first-page":"141","DOI":"10.11613\/BM.2015.015","article-title":"Understanding Bland Altman Analysis","volume":"25","author":"Giavarina D.","year":"2015","journal-title":"Biochemia Medica"},{"key":"e_1_2_12_13_1","doi-asserted-by":"crossref","first-page":"26","DOI":"10.4037\/ajcc2005.14.1.26","article-title":"New\u2010Generation Pulse Oximetry in the Care of Critically Ill Patients","volume":"14","author":"Giuliano K.","year":"2005","journal-title":"American Journal of Critical Care"},{"key":"e_1_2_12_14_1","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1016\/S0952-8180(99)00010-0","article-title":"Delays in the Detection of Hypoxemia due to Site of Pulse Oximetry Probe Placement","volume":"11","author":"Hamber E.","year":"1999","journal-title":"Journal of Clinical Anesthesia"},{"key":"e_1_2_12_15_1","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1164\/ajrccm.165.1.2009062","article-title":"Obstructive Apnoea During Sleep Is Associated With Peripheral Vasoconstriction","volume":"165","author":"Imadojemu V.","year":"2002","journal-title":"American Journal of Respiratory and Critical Care Medicine"},{"key":"e_1_2_12_16_1","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1186\/s13054-015-0984-8","article-title":"Pulse Oximetry","volume":"19","author":"Jubran A.","year":"2015","journal-title":"Critical Care"},{"key":"e_1_2_12_17_1","doi-asserted-by":"crossref","first-page":"787","DOI":"10.1097\/00000542-198911000-00028","article-title":"The Penumbra Effect: Vasomotion Dependent Pulse Oximeter Artefact due to Probe Malposition","volume":"71","author":"Kelleher J.","year":"1989","journal-title":"Anesthesiology"},{"key":"e_1_2_12_18_1","doi-asserted-by":"crossref","first-page":"336","DOI":"10.1053\/rmed.2001.1046","article-title":"How Accurate Are Pulse Oximeters in Patients With Acute Exacerbations of Chronic Obstructive Airways Disease?","volume":"95","author":"Kelly A. M.","year":"2001","journal-title":"Respiratory Medicine"},{"key":"e_1_2_12_19_1","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1016\/j.bspc.2015.12.006","article-title":"Analysing the Effects of Cold, Normal, and Warm Digits on Transmittance Pulse Oximetry","volume":"26","author":"Khan M.","year":"2016","journal-title":"Biomedical Signal Processing and Control"},{"key":"e_1_2_12_20_1","doi-asserted-by":"crossref","first-page":"71","DOI":"10.5664\/jcsm.5398","article-title":"Agreement in the Scoring of Respiratory Events Among International Sleep Centers for Home Sleep Testing","volume":"12","author":"Magalang U. J.","year":"2016","journal-title":"Journal of Clinical Sleep Medicine"},{"key":"e_1_2_12_21_1","volume-title":"Radical 7 Signal Extraction, Pulse Co\u2010Oximeter: Operator's Manual","author":"Masimo Corporation","year":"2017"},{"key":"e_1_2_12_22_1","doi-asserted-by":"crossref","first-page":"1027","DOI":"10.2147\/NSS.S463026","article-title":"Performance Investigation of Somfit Sleep Staging Algorithm","volume":"16","author":"McMahon M.","year":"2024","journal-title":"Nature and Science of Sleep"},{"key":"e_1_2_12_23_1","doi-asserted-by":"crossref","first-page":"108092","DOI":"10.1016\/j.rmed.2025.108092","article-title":"A Wearable Ring Oximeter for Detection of Sleep Disordered Breathing","volume":"242","author":"Meira E Cruz M.","year":"2025","journal-title":"Respiratory Medicine"},{"key":"e_1_2_12_24_1","first-page":"149","article-title":"Obstructive Sleep Apnoea: A Growing Problem","volume":"9","author":"Motamedi K.","year":"2009","journal-title":"Ochsner Journal"},{"key":"e_1_2_12_25_1","doi-asserted-by":"crossref","first-page":"1718","DOI":"10.1007\/s00134-012-2659-0","article-title":"Pulse Oximetry and High\u2010Dose Vasopressors: A Comparison Between Forehead Reflectance and Finger Transmission Sensors","volume":"38","author":"Nesseler N.","year":"2012","journal-title":"Intensive Care Medicine"},{"key":"e_1_2_12_26_1","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1111\/j.1365-2044.2004.03673.x","article-title":"Forehead SpO2 Monitoring Compared to Finger SpO2 Recording in Emergency Transport","volume":"59","author":"Nuhr M.","year":"2004","journal-title":"Anaesthesia"},{"key":"e_1_2_12_27_1","first-page":"349","article-title":"Comparison of Fingertip and Earlobe Pulse Oximetry With Arterial Blood Gas Results","volume":"48","author":"Olive S.","year":"2016","journal-title":"European Respiratory Journal"},{"key":"e_1_2_12_28_1","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1007\/BF01618081","article-title":"Reflection and Transmission Pulse Oximetry During Compromised Peripheral Perfusion","volume":"8","author":"Palve H.","year":"1992","journal-title":"Journal of Clinical Monitoring and Computing"},{"key":"e_1_2_12_29_1","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1213\/01.ane.0000278134.47777.a5","article-title":"The Effect of Motion on Pulse Oximetry and Its Clinical Significance","volume":"105","author":"Petterson M.","year":"2007","journal-title":"Anesthesia & Analgesia"},{"key":"e_1_2_12_30_1","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1186\/s12912-018-0283-1","article-title":"Accuracy of Pulse Oximetry in Detection of Oxygen Saturation in Patients Admitted to the Intensive Care Unit of Heart Surgery: Comparison of Finger, Toe, Forehead and Earlobe Probes","volume":"17","author":"Sohila S.","year":"2018","journal-title":"BMC Nursing"},{"key":"e_1_2_12_31_1","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1378\/chest.124.4_MeetingAbstracts.178S-c","article-title":"Reliability of Forehead Pulse Oximetry in Critically Ill Patients","volume":"124","author":"Sun S. W.","year":"2003","journal-title":"Chest"},{"key":"e_1_2_12_32_1","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1007\/s10877-006-9022-3","article-title":"Effect of Peripheral Vasoconstriction on Pulse Oximetry","volume":"20","author":"Talke P.","year":"2006","journal-title":"Journal of Clinical Monitoring and Computing"},{"key":"e_1_2_12_33_1","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1053\/j.tcam.2013.06.006","article-title":"Pulse Oximetry and Capnometry","volume":"28","author":"Thawley V.","year":"2013","journal-title":"Topics in Companion Animal Medicine"},{"key":"e_1_2_12_34_1","volume-title":"Radiometer: The tcpCO2 Handbook","author":"Thomsen A.","year":"2012"},{"key":"e_1_2_12_35_1","doi-asserted-by":"crossref","first-page":"1847","DOI":"10.1213\/ANE.0b013e3181bbc446","article-title":"A Comparison of Transmittance and Reflectance Pulse Oximetry During Vascular Surgery","volume":"109","author":"Wax B.","year":"2009","journal-title":"Anesthesia and Analgesia"},{"key":"e_1_2_12_36_1","doi-asserted-by":"crossref","first-page":"1143","DOI":"10.1111\/resp.12129","article-title":"Comparing Finger and Forehead Sensors to Measure Oxygen Saturation in People With Chronic Obstructive Pulmonary Disease","volume":"18","author":"Wilson S.","year":"2013","journal-title":"Respirology"},{"key":"e_1_2_12_37_1","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1007\/BF03356574","article-title":"Effect of Local Limb Temperature on Pulse Oximetry and the Plethysmographic Pulse Wave","volume":"14","author":"Wolfgang M.","year":"1997","journal-title":"Journal of Clinical Monitoring and Computing"},{"key":"e_1_2_12_38_1","doi-asserted-by":"crossref","first-page":"e39","DOI":"10.1016\/j.apnr.2010.03.002","article-title":"Comparison of Oxygen Saturation Values and Measurement Times by Pulse Oximetry in Various Parts of the Body","volume":"24","author":"Y\u00f6nt G. H.","year":"2011","journal-title":"Applied Nursing Research"}],"container-title":["Journal of Sleep Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jsr.70400","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/jsr.70400","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/jsr.70400","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T04:21:35Z","timestamp":1784262095000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jsr.70400"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,16]]},"references-count":37,"alternative-id":["10.1111\/jsr.70400"],"URL":"https:\/\/doi.org\/10.1111\/jsr.70400","archive":["Portico"],"relation":{},"ISSN":["0962-1105","1365-2869"],"issn-type":[{"value":"0962-1105","type":"print"},{"value":"1365-2869","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,16]]},"assertion":[{"value":"2026-02-06","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-06-17","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-07-16","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70400"}}