{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,12]],"date-time":"2026-04-12T01:09:23Z","timestamp":1775956163526,"version":"3.50.1"},"reference-count":26,"publisher":"Oxford University Press (OUP)","issue":"2","license":[{"start":{"date-parts":[[2014,3,1]],"date-time":"2014-03-01T00:00:00Z","timestamp":1393632000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2014,3,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Transjugular liver biopsy (TJLB) is used in humans at risk of bleeding. There are no reports of its use in veterinary medicine.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To assess the efficacy and potential complications of TJLB in canine cadavers, and compare with samples obtained via needle liver biopsy (NLB) and surgical liver biopsy (SLB).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Animals<\/jats:title>\n                    <jats:p>Twenty-five medium and large breed canine cadavers.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Prospective study. TJLBs were procured through the right jugular vein. After biopsy, intravenous contrast and gross inspection were used to assess the biopsy site. Minor and major complications were recorded. NLBs and SLBs were then obtained. Histopathology was performed, and TJLB and NLB were compared for number of complete portal tracts (CPTs), length, and fragmentation. Pathologic process and autolysis were assessed in all samples.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>All TJLBs yielded liver tissue. The proportion of minor complications was 12\/25 (48%), and major complications 16\/25 (64%); 13\/16 (81%) of the major complications were liver capsule perforation. In 21\/25 (84%), the histopathology in the SLB was reflected in the TJLBs. For cases with minimal autolysis, median number of CPTs in TJLBs was 7.5, compared with 4 in NLBs (P = .018). Median length of TJLB specimen was 28 mm compared to 22 mm in NLBs (P = .007). Fragmentation rate was median of 1.25 for TJLB compared to 1.50 in NLBs (P = .11).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions and Clinical Importance<\/jats:title>\n                    <jats:p>TJLB is technically feasible and achieves comparable results to NLB and SLB. The number of complications, in particular liver capsule perforation, was greater than expected. Further studies are indicated before clinical use is recommended.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/jvim.12305","type":"journal-article","created":{"date-parts":[[2014,2,4]],"date-time":"2014-02-04T13:19:21Z","timestamp":1391519961000},"page":"338-345","source":"Crossref","is-referenced-by-count":7,"title":["Assessment of the Efficacy and Potential Complications of Transjugular Liver Biopsy in Canine Cadavers"],"prefix":"10.1093","volume":"28","author":[{"given":"A.S.","family":"Levien","sequence":"first","affiliation":[{"name":"The Animal Medical Center Department of Surgery, , New York, NY"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.","family":"Weisse","sequence":"additional","affiliation":[{"name":"The Animal Medical Center Department of Interventional Radiology and Interventional Endoscopy, , New York, NY"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T.A.","family":"Donovan","sequence":"additional","affiliation":[{"name":"The Animal Medical Center Department of Pathology, , New York, NY"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.C.","family":"Berent","sequence":"additional","affiliation":[{"name":"The Animal Medical Center Department of Interventional Radiology and Interventional Endoscopy, , New York, NY"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2014,3,1]]},"reference":[{"key":"2026020304371799500_jvim12305-bib-0001","doi-asserted-by":"crossref","first-page":"1789","DOI":"10.1136\/gut.2005.090415","article-title":"Transjugular liver biopsy: How good is it for accurate histological interpretation?","volume":"55","author":"Cholongitas","year":"2006","journal-title":"Gut"},{"key":"2026020304371799500_jvim12305-bib-0002","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1016\/j.jhep.2007.05.001","article-title":"Transjugular liver biopsy\u2013indications, adequacy, quality of specimens, and complications \u2013 A systematic review","volume":"47","author":"Kalambokis","year":"2007","journal-title":"J Hepatol"},{"key":"2026020304371799500_jvim12305-bib-0003","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1056\/NEJM200102153440706","article-title":"Liver biopsy","volume":"344","author":"Bravo","year":"2001","journal-title":"N Engl J Med"},{"key":"2026020304371799500_jvim12305-bib-0004","doi-asserted-by":"crossref","first-page":"e269","DOI":"10.1016\/j.ejrad.2010.12.016","article-title":"Transjugular liver biopsy in liver transplant patients using an 18-gauge automated core biopsy needle","volume":"80","author":"Miraglia","year":"2011","journal-title":"Eur J Radiol"},{"key":"2026020304371799500_jvim12305-bib-0005","doi-asserted-by":"crossref","first-page":"1036","DOI":"10.1002\/hep.1840150611","article-title":"Transjugular liver biopsy in children","volume":"15","author":"Furuya","year":"1992","journal-title":"Hepatology"},{"key":"2026020304371799500_jvim12305-bib-0006","doi-asserted-by":"crossref","first-page":"711","DOI":"10.1007\/s00261-002-0020-8","article-title":"Transjugular liver biopsy: Assessment of safety and efficacy of the Quick-Core biopsy needle","volume":"27","author":"Bruzzi","year":"2002","journal-title":"Abdom Imaging"},{"key":"2026020304371799500_jvim12305-bib-0007","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1111\/j.1399-3046.2011.01605.x","article-title":"Transjugular liver biopsy in pediatric patients with left split liver transplantation and severe coagulation impairment","volume":"16","author":"Miraglia","year":"2012","journal-title":"Pediatr Transplant"},{"key":"2026020304371799500_jvim12305-bib-0008","doi-asserted-by":"crossref","first-page":"167","DOI":"10.2214\/ajr.180.1.1800167","article-title":"Transjugular biopsy of the liver in pediatric and adult patients using an 18-gauge automated core biopsy needle: A retrospective review of 410 consecutive procedures","volume":"180","author":"Smith","year":"2003","journal-title":"Am J Roentgenol"},{"key":"2026020304371799500_jvim12305-bib-0009","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1007\/s00270-009-9743-z","article-title":"A comparison of transjugular and plugged-percutaneous liver biopsy in patients with contraindications to ordinary percutaneous liver biopsy and an \u201cin-house\u201d protocol for selecting the procedure of choice","volume":"33","author":"Atar","year":"2010","journal-title":"Cardiovasc Intervent Radiol"},{"key":"2026020304371799500_jvim12305-bib-0010","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1007\/s00270-008-9412-7","article-title":"A comparison of four- versus three-pass transjugular biopsy using a 19-G Tru-Cut needle and a randomized study using a cassette to prevent biopsy fragmentation","volume":"32","author":"Vibhakorn","year":"2009","journal-title":"Cardiovasc Intervent Radiol"},{"key":"2026020304371799500_jvim12305-bib-0011","doi-asserted-by":"crossref","first-page":"964","DOI":"10.1136\/pgmj.68.806.964","article-title":"Complications associated with percutaneous needle biopsy of the liver when one, two or three specimens are taken","volume":"68","author":"Maharaj","year":"1992","journal-title":"Postgrad Med J"},{"key":"2026020304371799500_jvim12305-bib-0012","doi-asserted-by":"crossref","first-page":"1017","DOI":"10.1002\/hep.22742","article-title":"Liver biopsy","volume":"49","author":"Rockey","year":"2009","journal-title":"Hepatology"},{"key":"2026020304371799500_jvim12305-bib-0013","first-page":"1","article-title":"Guidelines on the Use of Liver Biopsy in Clinical Practice","volume-title":"British Society of Gastroenterology","author":"Neuberger","year":"2004"},{"key":"2026020304371799500_jvim12305-bib-0014","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1016\/B978-0-7020-2791-8.50006-X","volume-title":"WSAVA Standards for Clinical and Histological Diagnoses of Canine and Feline Liver Diseases","author":"Rothuizen","year":"2006"},{"key":"2026020304371799500_jvim12305-bib-0015","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1148\/82.2.312","article-title":"Catheter biopsy. Experimental technique for transvenous liver biopsy","volume":"82","author":"Dotter","year":"1964","journal-title":"Radiology"},{"issue":"2","key":"2026020304371799500_jvim12305-bib-0016","doi-asserted-by":"crossref","first-page":"IV1","DOI":"10.1136\/gut.45.2008.iv1","article-title":"Guidelines on the use of liver biopsy in clinical practice. British Society of Gastroenterology","volume":"45","author":"Grant","year":"1999","journal-title":"Gut"},{"key":"2026020304371799500_jvim12305-bib-0017","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1111\/j.1748-5827.1995.tb02843.x","article-title":"Percutaneous biopsy of abdominal organs under ultrasound guidance","volume":"36","author":"Barr","year":"1995","journal-title":"J Small Anim Pract"},{"key":"2026020304371799500_jvim12305-bib-0018","doi-asserted-by":"crossref","first-page":"1327","DOI":"10.1111\/j.1939-1676.2006.tb00746.x","article-title":"High complication rate of an automatic Tru-Cut biopsy gun device for liver biopsy in cats","volume":"20","author":"Proot","year":"2006","journal-title":"J Vet Intern Med"},{"key":"2026020304371799500_jvim12305-bib-0019","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1002\/hep.510280206","article-title":"The normal adult human liver biopsy: A quantitative reference standard","volume":"28","author":"Crawford","year":"1998","journal-title":"Hepatology"},{"key":"2026020304371799500_jvim12305-bib-0020","doi-asserted-by":"crossref","first-page":"413","DOI":"10.2460\/javma.1993.203.03.413","article-title":"Complications after ultrasound-guided biopsy of abdominal structures in dogs and cats: 246 cases (1984-1991)","volume":"203","author":"Leveille","year":"1993","journal-title":"J Am Vet Med Assoc"},{"key":"2026020304371799500_jvim12305-bib-0021","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1111\/j.1532-950X.2008.00467.x","article-title":"Hilar liver resection in dogs","volume":"38","author":"Covey","year":"2009","journal-title":"Vet Surg"},{"key":"2026020304371799500_jvim12305-bib-0022","first-page":"385","volume-title":"Miller's Anatomy of the Dog","author":"Evans","year":"1993","edition":"3rd ed"},{"key":"2026020304371799500_jvim12305-bib-0023","first-page":"1601","volume-title":"Veterinary Surgery Small Animal","author":"Mayhew","year":"2012"},{"key":"2026020304371799500_jvim12305-bib-0024","doi-asserted-by":"crossref","first-page":"228","DOI":"10.5326\/15473317-37-3-228","article-title":"Correlation between coagulation profile findings and bleeding complications after ultrasound-guided biopsies: 434 cases (1993-1996)","volume":"37","author":"Bigge","year":"2001","journal-title":"J Am Anim Hosp Assoc"},{"key":"2026020304371799500_jvim12305-bib-0025","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/j.dld.2006.06.038","article-title":"The transjugular route: The key hole to the liver world","volume":"39","author":"Senzolo","year":"2007","journal-title":"Dig Liver Dis"},{"key":"2026020304371799500_jvim12305-bib-0026","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1016\/S0009-9260(02)00576-7","article-title":"Transvenous liver biopsy via the femoral vein","volume":"58","author":"Khosa","year":"2003","journal-title":"Clin Radiol"}],"container-title":["Journal of Veterinary Internal Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fjvim.12305","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fjvim.12305","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/academic.oup.com\/jvim\/article-pdf\/28\/2\/338\/66686605\/jvim12305.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jvim\/article-pdf\/28\/2\/338\/66686605\/jvim12305.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,3]],"date-time":"2026-02-03T09:37:55Z","timestamp":1770111475000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jvim\/article\/28\/2\/338\/8452243"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,3,1]]},"references-count":26,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2014,3,1]]}},"URL":"https:\/\/doi.org\/10.1111\/jvim.12305","relation":{},"ISSN":["1939-1676"],"issn-type":[{"value":"1939-1676","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2014,3]]},"published":{"date-parts":[[2014,3,1]]}}}