{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,22]],"date-time":"2025-10-22T21:04:50Z","timestamp":1761167090927,"version":"build-2065373602"},"reference-count":53,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2020,6,1]],"date-time":"2020-06-01T00:00:00Z","timestamp":1590969600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,6,1]],"date-time":"2020-06-01T00:00:00Z","timestamp":1590969600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["neuromodulationjournal.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Neuromodulation: Technology at the Neural Interface"],"published-print":{"date-parts":[[2020,6]]},"DOI":"10.1111\/ner.13022","type":"journal-article","created":{"date-parts":[[2019,7,19]],"date-time":"2019-07-19T12:54:50Z","timestamp":1563540890000},"page":"530-536","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Clinical Efficacy of Bilateral Deep Brain Stimulation Does Not Change After Implantable Pulse Generator Replacement but the Impedances Do: A Prospective Study"],"prefix":"10.1016","volume":"23","author":[{"given":"Marcel","family":"Niemann","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gerd-Helge","family":"Schneider","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrea","family":"K\u00fchn","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter","family":"Vajkoczy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9969-0141","authenticated-orcid":false,"given":"Katharina","family":"Faust","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1111\/ner.13022_bib1","doi-asserted-by":"crossref","first-page":"25285","DOI":"10.1038\/srep25285","article-title":"Effects of neurostimulation for advanced Parkinson\u2019s disease patients on motor symptoms: a multiple-treatments meta-analysas of randomized controlled trials","volume":"6","author":"Xie","year":"2016","journal-title":"Sci Rep"},{"key":"10.1111\/ner.13022_bib2","doi-asserted-by":"crossref","first-page":"714","DOI":"10.1007\/s00415-012-6628-x","article-title":"Treatment of essential tremor: a systematic review of evidence and recommendations from the Italian movement disorders association","volume":"260","author":"Zappia","year":"2013","journal-title":"J Neurol"},{"key":"10.1111\/ner.13022_bib3","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1111\/ene.13255","article-title":"Efficacy of pallidal stimulation in isolated dystonia: a systematic review and meta-analysis","volume":"24","author":"Moro","year":"2017","journal-title":"Eur J Neurol"},{"key":"10.1111\/ner.13022_bib4","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1111\/ner.12604","article-title":"State of the art: novel applications for deep brain stimulation","volume":"21","author":"Roy","year":"2018","journal-title":"Neuromodulation"},{"key":"10.1111\/ner.13022_bib5","doi-asserted-by":"crossref","first-page":"1489","DOI":"10.1111\/ene.13103","article-title":"EAN guidelines on central neurostimulation therapy in chronic pain conditions","volume":"23","author":"Cruccu","year":"2016","journal-title":"Eur J Neurol"},{"key":"10.1111\/ner.13022_bib6","first-page":"CD008497","article-title":"Deep brain and cortical stimulation for epilepsy","volume":"7","author":"Sprengers","year":"2017","journal-title":"Cochrane Database Syst Rev"},{"key":"10.1111\/ner.13022_bib7","doi-asserted-by":"crossref","first-page":"3533","DOI":"10.1017\/S0033291714000981","article-title":"Deep brain stimulation for obsessive-compulsive disorder: a systematic review and meta-analysis","volume":"44","author":"Kisely","year":"2014","journal-title":"Psychol Med"},{"key":"10.1111\/ner.13022_bib8","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1016\/j.brs.2015.11.005","article-title":"Deep brain stimulation for Tourette-syndrome: a systematic review and meta-analysis","volume":"9","author":"Baldermann","year":"2016","journal-title":"Brain Stimul"},{"key":"10.1111\/ner.13022_bib9","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1001\/2013.jamaneurol.45","article-title":"History, applications, and mechanisms of deep brain stimulation","volume":"70","author":"Miocinovic","year":"2013","journal-title":"JAMA Neurol"},{"key":"10.1111\/ner.13022_bib10","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1111\/j.1525-1403.2011.00406.x","article-title":"Rechargeable internal neural stimulators--is there a problem with efficacy?","volume":"15","author":"Harries","year":"2012","journal-title":"Neuromodulation"},{"key":"10.1111\/ner.13022_bib11","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1159\/000337768","article-title":"Rechargeable deep brain stimulators in the management of paediatric dystonia: well tolerated with a low complication rate","volume":"90","author":"Kaminska","year":"2012","journal-title":"Stereotact Funct Neurosurg"},{"key":"10.1111\/ner.13022_bib12","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1159\/000342236","article-title":"A new rechargeable device for deep brain stimulation: a prospective patient satisfaction survey","volume":"69","author":"Timmermann","year":"2013","journal-title":"Eur Neurol"},{"key":"10.1111\/ner.13022_bib13","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1111\/ner.12026","article-title":"Rechargeable vs. nonrechargeable internal pulse generators in the management of dystonia","volume":"16","author":"Gillies","year":"2013","journal-title":"Neuromodulation"},{"key":"10.1111\/ner.13022_bib14","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1111\/ner.12115","article-title":"Rechargeable deep brain stimulation implantable pulse generators in movement disorders: patient satisfaction and conversion parameters","volume":"17","author":"Waln","year":"2014","journal-title":"Neuromodulation"},{"key":"10.1111\/ner.13022_bib15","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1016\/S1474-4422(15)00087-3","article-title":"Multiple-source current steering in subthalamic nucleus deep brain stimulation for Parkinson\u2019s disease (the VANTAGE study): a non-randomised, prospective, multicentre, open-label study","volume":"14","author":"Timmermann","year":"2015","journal-title":"Lancet Neurol"},{"key":"10.1111\/ner.13022_bib16","doi-asserted-by":"crossref","first-page":"996","DOI":"10.3109\/00207454.2015.1092145","article-title":"Patient perspectives on the efficacy of a new kind of rechargeable deep brain stimulators","volume":"126","author":"Jia","year":"2016","journal-title":"Int J Neurosci"},{"key":"10.1111\/ner.13022_bib17","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1111\/ner.12577","article-title":"Rechargeable stimulators in deep brain stimulation for obsessive-compulsive disorder: a prospective interventional cohort study","volume":"21","author":"De Vloo","year":"2018","journal-title":"Neuromodulation"},{"key":"10.1111\/ner.13022_bib18","doi-asserted-by":"crossref","first-page":"604","DOI":"10.1111\/ner.12748","article-title":"Rechargeable internal pulse generators as initial Neurostimulators for deep brain stimulation in patients with movement disorders","volume":"21","author":"Jakobs","year":"2018","journal-title":"Neuromodulation"},{"key":"10.1111\/ner.13022_bib19","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1111\/ner.12810","article-title":"Fixed-life or rechargeable battery for deep brain stimulation: which do patients prefer?","volume":"22","author":"Khaleeq","year":"2018","journal-title":"Neuromodulation"},{"key":"10.1111\/ner.13022_bib20","doi-asserted-by":"crossref","first-page":"1020","DOI":"10.1016\/j.wneu.2015.05.028","article-title":"Internal pulse generators in deep brain stimulation: rechargeable or not?","volume":"84","author":"Rizzi","year":"2015","journal-title":"World Neurosurg"},{"key":"10.1111\/ner.13022_bib21","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1111\/ner.12550","article-title":"Rechargeable or nonrechargeable deep brain stimulation in dystonia: a cost analysis","volume":"20","author":"Perez","year":"2017","journal-title":"Neuromodulation"},{"key":"10.1111\/ner.13022_bib22","doi-asserted-by":"crossref","first-page":"836","DOI":"10.1016\/j.brs.2017.04.120","article-title":"Cost-effectiveness of deep brain stimulation versus treatment as usual for obsessive-compulsive disorder","volume":"10","author":"Ooms","year":"2017","journal-title":"Brain Stimul"},{"key":"10.1111\/ner.13022_bib23","first-page":"1","article-title":"Reduced long-term cost and increased patient satisfaction with rechargeable implantable pulse generators for deep brain stimulation","volume":"28","author":"Hitti","year":"2018","journal-title":"J Neurosurg"},{"key":"10.1111\/ner.13022_bib24","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1111\/ner.12782","article-title":"Cost-minimization analysis of deep-brain stimulation using National Database of Japanese health insurance claims","volume":"21","author":"Akazawa","year":"2018","journal-title":"Neuromodulation"},{"key":"10.1111\/ner.13022_bib25","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1159\/000343202","article-title":"The risk of hardware infection in deep brain stimulation surgery is greater at impulse generator replacement than at the primary procedure","volume":"91","author":"Pepper","year":"2013","journal-title":"Stereotact Funct Neurosurg"},{"key":"10.1111\/ner.13022_bib26","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1159\/000365576","article-title":"Increasing infection rate in multiple implanted pulse generator changes in movement disorder patients treated with deep brain stimulation","volume":"92","author":"Thrane","year":"2014","journal-title":"Stereotact Funct Neurosurg"},{"key":"10.1111\/ner.13022_bib27","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1159\/000447521","article-title":"Surgical replacement of implantable pulse generators in deep brain stimulation: adverse events and risk factors in a Multicenter cohort","volume":"94","author":"Fytagoridis","year":"2016","journal-title":"Stereotact Funct Neurosurg"},{"key":"10.1111\/ner.13022_bib28","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1159\/000321710","article-title":"Longevity analysis of currently available deep brain stimulation devices","volume":"89","author":"Halpern","year":"2011","journal-title":"Stereotact Funct Neurosurg"},{"key":"10.1111\/ner.13022_bib29","doi-asserted-by":"crossref","first-page":"1091","DOI":"10.1007\/s00381-012-1728-6","article-title":"Battery life following pallidal deep brain stimulation (DBS) in children and young people with severe primary and secondary dystonia","volume":"28","author":"Lumsden","year":"2012","journal-title":"Childs Nerv Syst"},{"key":"10.1111\/ner.13022_bib30","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1007\/s00702-016-1562-1","article-title":"Disease-specific longevity of impulse generators in deep brain stimulation and review of the literature","volume":"123","author":"van Riesen","year":"2016","journal-title":"J Neural Transm (Vienna)"},{"key":"10.1111\/ner.13022_bib31","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1111\/ner.12743","article-title":"Longevity of implantable pulse generators in bilateral deep brain stimulation for movement disorders","volume":"21","author":"Niemann","year":"2018","journal-title":"Neuromodulation"},{"key":"10.1111\/ner.13022_bib32","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1159\/000488684","article-title":"Battery longevity comparison of two commonly available dual channel implantable pulse generators used for subthalamic nucleus stimulation in Parkinson\u2019s disease","volume":"96","author":"Fisher","year":"2018","journal-title":"Stereotact Funct Neurosurg"},{"key":"10.1111\/ner.13022_bib33","doi-asserted-by":"crossref","first-page":"1274","DOI":"10.3171\/2009.1.JNS081352","article-title":"Stability of symptom control after replacement of impulse generators for deep brain stimulation","volume":"110","author":"Allert","year":"2009","journal-title":"J Neurosurg"},{"key":"10.1111\/ner.13022_bib34","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1159\/000319958","article-title":"Less is more: adaptation of voltage after battery replacement in deep brain stimulation for dystonia","volume":"88","author":"Blahak","year":"2010","journal-title":"Stereotact Funct Neurosurg"},{"key":"10.1111\/ner.13022_bib35","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1159\/000336342","article-title":"Shielded battery syndrome: a new hardware complication of deep brain stimulation","volume":"90","author":"Chelvarajah","year":"2012","journal-title":"Stereotact Funct Neurosurg"},{"key":"10.1111\/ner.13022_bib36","unstructured":"Goetz CG, Poewe W, Dubois B, Schrag A, Stern MB, Lang AE, et al. Official Working Document\u2013\u2013MDS-UPDRS. 2008. http:\/\/www.movementdisorders.org\/MDS-Files1\/PDFs\/MDS-UPDRS-Rating-Scales\/MDS_UPDRS_German_Offical_Working_Document.pdf"},{"key":"10.1111\/ner.13022_bib37","doi-asserted-by":"crossref","first-page":"2129","DOI":"10.1002\/mds.22340","article-title":"Movement Disorder Society-sponsored revision of the unified Parkinson\u2019s disease rating scale (MDS-UPDRS): scale presentation and clinimetric testing results","volume":"23","author":"Goetz","year":"2008","journal-title":"Mov Disord"},{"key":"10.1111\/ner.13022_bib38","series-title":"Parkinson\u2019s disease and movement disorders","first-page":"271","article-title":"Clinical rating scale for tremor","author":"Fahn","year":"1993"},{"key":"10.1111\/ner.13022_bib39","series-title":"Bewegungsst\u00f6rungen","first-page":"413","article-title":"Anhang - Beurteilungsskalen","author":"Ceballos-Baumann","year":"2005"},{"key":"10.1111\/ner.13022_bib40","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1002\/mds.10377","article-title":"Rating scales for dystonia: a multicenter assessment","volume":"18","author":"Comella","year":"2003","journal-title":"Mov Disord"},{"key":"10.1111\/ner.13022_bib41","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1002\/ana.20525","article-title":"Calculating total electrical energy delivered by deep brain stimulation systems","volume":"58","author":"Koss","year":"2005","journal-title":"Ann Neurol"},{"key":"10.1111\/ner.13022_bib42","doi-asserted-by":"crossref","first-page":"706","DOI":"10.1212\/WNL.59.5.706","article-title":"The impact on Parkinson\u2019s disease of electrical parameter settings in STN stimulation","volume":"59","author":"Moro","year":"2002","journal-title":"Neurology"},{"key":"10.1111\/ner.13022_bib43","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1159\/000075161","article-title":"Longevity of batteries in internal pulse generators used for deep brain stimulation","volume":"80","author":"Bin-Mahfoodh","year":"2003","journal-title":"Stereotact Funct Neurosurg"},{"key":"10.1111\/ner.13022_bib44","doi-asserted-by":"crossref","first-page":"2436","DOI":"10.1002\/mds.21726","article-title":"Lifetime of Itrel II pulse generators for subthalamic nucleus stimulation in Parkinson\u2019s disease","volume":"22","author":"Anheim","year":"2007","journal-title":"Mov Disord"},{"key":"10.1111\/ner.13022_bib45","doi-asserted-by":"crossref","first-page":"872","DOI":"10.1111\/j.1468-1331.2010.03290.x","article-title":"Battery lifetime in pallidal deep brain stimulation for dystonia","volume":"18","author":"Blahak","year":"2011","journal-title":"Eur J Neurol"},{"key":"10.1111\/ner.13022_bib46","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1001\/archneurol.2009.20","article-title":"Deep brain stimulation for primary generalized dystonia: long-term outcomes","volume":"66","author":"Isaias","year":"2009","journal-title":"Arch Neurol"},{"key":"10.1111\/ner.13022_bib47","doi-asserted-by":"crossref","first-page":"2128","DOI":"10.1016\/j.clinph.2010.04.026","article-title":"Current-controlled deep brain stimulation reduces in vivo voltage fluctuations observed during voltage-controlled stimulation","volume":"121","author":"Lempka","year":"2010","journal-title":"Clin Neurophysiol"},{"key":"10.1111\/ner.13022_bib48","doi-asserted-by":"crossref","first-page":"804","DOI":"10.1227\/NEU.0b013e3182676b91","article-title":"Long-term recordings of local field potentials from implanted deep brain stimulation electrodes","volume":"71","author":"Abosch","year":"2012","journal-title":"Neurosurgery"},{"key":"10.1111\/ner.13022_bib49","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1159\/000358014","article-title":"Variation in deep brain stimulation electrode impedance over years following electrode implantation","volume":"92","author":"Satzer","year":"2014","journal-title":"Stereotact Funct Neurosurg"},{"key":"10.1111\/ner.13022_bib50","doi-asserted-by":"crossref","first-page":"1247","DOI":"10.1016\/j.parkreldis.2015.07.019","article-title":"Long-term evaluation of impedance levels and clinical development in subthalamic deep brain stimulation for Parkinson\u2019s disease","volume":"21","author":"Hartmann","year":"2015","journal-title":"Parkinsonism Relat Disord"},{"key":"10.1111\/ner.13022_bib51","doi-asserted-by":"crossref","first-page":"718","DOI":"10.1016\/j.brs.2013.02.001","article-title":"Long-term measurement of impedance in chronically implanted depth and subdural electrodes during responsive neurostimulation in humans","volume":"6","author":"Sillay","year":"2013","journal-title":"Brain Stimul"},{"key":"10.1111\/ner.13022_bib52","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1002\/1531-8249(200009)48:3<372::AID-ANA12>3.0.CO;2-0","article-title":"No tissue damage by chronic deep brain stimulation in Parkinson\u2019s disease","volume":"48","author":"Haberler","year":"2000","journal-title":"Ann Neurol"},{"key":"10.1111\/ner.13022_bib53","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1016\/j.clinph.2005.10.007","article-title":"Sources and effects of electrode impedance during deep brain stimulation","volume":"117","author":"Butson","year":"2006","journal-title":"Clin Neurophysiol"}],"container-title":["Neuromodulation: Technology at the Neural Interface"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fner.13022","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/ner.13022","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/ner.13022","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1094715921021450?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1094715921021450?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/ner.13022","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T21:59:10Z","timestamp":1761083950000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1094715921021450"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6]]},"references-count":53,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2020,6]]}},"alternative-id":["S1094715921021450"],"URL":"https:\/\/doi.org\/10.1111\/ner.13022","relation":{},"ISSN":["1094-7159"],"issn-type":[{"type":"print","value":"1094-7159"}],"subject":[],"published":{"date-parts":[[2020,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Clinical Efficacy of Bilateral Deep Brain Stimulation Does Not Change After Implantable Pulse Generator Replacement but the Impedances Do: A Prospective Study","name":"articletitle","label":"Article Title"},{"value":"Neuromodulation: Technology at the Neural Interface","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1111\/ner.13022","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2020 International Neuromodulation Society. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}