{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T19:44:16Z","timestamp":1785527056639,"version":"3.56.0"},"reference-count":16,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2025,10,23]],"date-time":"2025-10-23T00:00:00Z","timestamp":1761177600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"},{"start":{"date-parts":[[2025,10,23]],"date-time":"2025-10-23T00:00:00Z","timestamp":1761177600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Nursing in Critical Care"],"published-print":{"date-parts":[[2025,11]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:label\/>\n                    <jats:p>Intracranial pressure (ICP) monitoring during magnetic resonance (MR) imaging is often discontinued due to safety concerns, as commonly used devices are not MR\u2010conditional for in\u00a0situ operation. Parenchymal probes must be disconnected, and external ventricular drainage (EVD) systems are typically closed or cannot be connected to MR\u2010conditional transducers, thereby limiting diagnostic opportunities in unstable neurocritical care patients. MR examinations in neurocritical care are often deferred\u2014or performed with ICP monitoring paused\u2014because commonly used devices are not MR\u2010conditional for in\u00a0situ operation: parenchymal probes must be disconnected and EVD systems are typically closed or cannot be connected to MR\u2010conditional transducers. This technical note describes the development of a custom\u2010made, MR\u2010safe support frame that enables continuous ICP monitoring and cerebrospinal fluid (CSF) drainage during scanning. The device complies with MR\u2010conditional requirements and allows for hydrostatic levelling to ensure accurate pressure readings.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Relevance to Clinical Practice<\/jats:title>\n                    <jats:p>This innovation may improve MR access for unstable patients by enabling earlier and repeated imaging, potentially allowing for earlier detection of secondary brain injury.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/nicc.70225","type":"journal-article","created":{"date-parts":[[2025,10,24]],"date-time":"2025-10-24T06:31:57Z","timestamp":1761287517000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Enabling Continuous Intracranial Pressure Monitoring During\n                    <scp>MRI<\/scp>\n                    : A Technical Note on the Development of an\n                    <scp>MR<\/scp>\n                    \u2010Safe Support Frame"],"prefix":"10.1111","volume":"30","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9928-4207","authenticated-orcid":false,"given":"Marcelo P.","family":"Martins","sequence":"first","affiliation":[{"name":"Department of Health, Medicine, and Caring Sciences Link\u00f6ping University  Link\u00f6ping Sweden"},{"name":"Clinical Department of Radiology in Link\u00f6ping, Region \u00d6sterg\u00f6tland  Link\u00f6ping Sweden"},{"name":"Center for Medical Image Science and Visualization (CMIV) Link\u00f6ping University  Link\u00f6ping Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Malin","family":"Ringholm","sequence":"additional","affiliation":[{"name":"Clinical Department of Neurosurgery in Link\u00f6ping, Region \u00d6sterg\u00f6tland  Link\u00f6ping Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jacob","family":"Engstr\u00f6m","sequence":"additional","affiliation":[{"name":"Clinical Department of Neurosurgery in Link\u00f6ping, Region \u00d6sterg\u00f6tland  Link\u00f6ping Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anders","family":"Tisell","sequence":"additional","affiliation":[{"name":"Center for Medical Image Science and Visualization (CMIV) Link\u00f6ping University  Link\u00f6ping Sweden"},{"name":"Clinical Department of Medical Radiation Physics, Region \u00d6sterg\u00f6tland  Link\u00f6ping Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,10,23]]},"reference":[{"key":"e_1_2_13_2_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00134\u2010022\u201006786\u2010y"},{"key":"e_1_2_13_3_1","doi-asserted-by":"publisher","DOI":"10.1146\/annurev\u2010bioeng\u2010060418\u2010052257"},{"key":"e_1_2_13_4_1","doi-asserted-by":"publisher","DOI":"10.1093\/neuros\/nyaa278"},{"key":"e_1_2_13_5_1","doi-asserted-by":"publisher","DOI":"10.3171\/2020.8.JNS202280"},{"key":"e_1_2_13_6_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12028\u2010016\u20100274\u20106"},{"key":"e_1_2_13_7_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12028\u2010016\u20100291\u20105"},{"key":"e_1_2_13_8_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12028\u2010012\u20109802\u20101"},{"key":"e_1_2_13_9_1","doi-asserted-by":"publisher","DOI":"10.1097\/CNQ.0000000000000557"},{"key":"e_1_2_13_10_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41467\u2010021\u201025441\u20106"},{"key":"e_1_2_13_11_1","doi-asserted-by":"publisher","DOI":"10.1001\/jamaneurol.2020.3263"},{"key":"e_1_2_13_12_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12028\u2010016\u20100308\u20100"},{"key":"e_1_2_13_13_1","doi-asserted-by":"publisher","DOI":"10.3390\/nursrep12040090"},{"key":"e_1_2_13_14_1","unstructured":"Invivo \u201cExpression Model MR400 MRI Patient Monitoring System Instructions for Use Revision E [Internet] \u201d(2018) https:\/\/www.documents.philips.com\/assets\/Instruction%20for%20Use\/20210714\/80d8544b18344c1da98fad6500f4166e.pdf."},{"key":"e_1_2_13_15_1","unstructured":"CODAN \u201cIBPM DPT\u20106000\/DPT\u20109000\/Xtrans Instructions for Use [Internet] \u201d(2021) https:\/\/www.codancompanies.com\/downloadcenter\/20_1034_00_language_package_vk_ii.pdf."},{"key":"e_1_2_13_16_1","doi-asserted-by":"publisher","DOI":"10.3390\/app8122634"},{"key":"e_1_2_13_17_1","doi-asserted-by":"publisher","DOI":"10.2463\/mrms.rev.2021-0047"}],"container-title":["Nursing in Critical Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/nicc.70225","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/nicc.70225","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/nicc.70225","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T18:08:20Z","timestamp":1785521300000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/nicc.70225"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,23]]},"references-count":16,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2025,11]]}},"alternative-id":["10.1111\/nicc.70225"],"URL":"https:\/\/doi.org\/10.1111\/nicc.70225","archive":["Portico"],"relation":{},"ISSN":["1362-1017","1478-5153"],"issn-type":[{"value":"1362-1017","type":"print"},{"value":"1478-5153","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,23]]},"assertion":[{"value":"2025-06-25","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-10-06","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-10-23","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70225"}}