{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T17:01:38Z","timestamp":1791219698797,"version":"4.1.0"},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2012,12,1]],"date-time":"2012-12-01T00:00:00Z","timestamp":1354320000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Ophthalmic Physiologic Optic"],"published-print":{"date-parts":[[2013,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>\n                      To evaluate the effects of the wearer's pupil size and spherical aberration on visual performance with centre\u2010near, aspheric multifocal contact lenses (\n                      <jats:styled-content style=\"fixed-case\">MFCL<\/jats:styled-content>\n                      s). The advantage of binocular over monocular vision was also investigated.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Twelve young volunteers, with an average age of 27\u00a0\u00b1\u00a05\u00a0years, participated in the study. Log\n                      <jats:styled-content style=\"fixed-case\">MAR V<\/jats:styled-content>\n                      isual\n                      <jats:styled-content style=\"fixed-case\">A<\/jats:styled-content>\n                      cuity (\n                      <jats:styled-content style=\"fixed-case\">VA<\/jats:styled-content>\n                      ) was measured under cycloplegia for a range of defocus levels (from +3.0 to \u22123.0\u00a0D, in 0.5\u00a0D steps) with no correction and with three aspheric\n                      <jats:styled-content style=\"fixed-case\">MFCL<\/jats:styled-content>\n                      s (\n                      <jats:styled-content style=\"fixed-case\">A<\/jats:styled-content>\n                      ir\n                      <jats:styled-content style=\"fixed-case\">O<\/jats:styled-content>\n                      ptix\n                      <jats:styled-content style=\"fixed-case\">A<\/jats:styled-content>\n                      qua\n                      <jats:styled-content style=\"fixed-case\">M<\/jats:styled-content>\n                      ultifocal) with a centre\u2010near design, providing correction for \u2018Low\u2019, \u2018Med\u2019 and \u2018High\u2019 near demands. Measurements were performed for all combinations of the following conditions: (1) artificial pupils of 6 and 3\u00a0mm diameter, (2) binocular and monocular (dominant eye) vision. Depth\u2010of\u2010focus (\n                      <jats:styled-content style=\"fixed-case\">DOF<\/jats:styled-content>\n                      ) was calculated from the\n                      <jats:styled-content style=\"fixed-case\">VA<\/jats:styled-content>\n                      vs defocus curves. Ocular aberrations under cycloplegia were measured using iTrace.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      <jats:styled-content style=\"fixed-case\">VA<\/jats:styled-content>\n                      at \u22123.0\u00a0D defocus (simulating near performance) was statistically higher for the 3\u00a0mm than for the 6\u00a0mm pupil (\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0=\u00a00.006), and for binocular rather than for monocular vision (\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0&lt;\u00a00.001). Similarly,\n                      <jats:styled-content style=\"fixed-case\">DOF<\/jats:styled-content>\n                      was better for the 3\u00a0mm pupil (\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0=\u00a00.002) and for binocular viewing conditions (\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0&lt;\u00a00.001). Both\n                      <jats:styled-content style=\"fixed-case\">VA<\/jats:styled-content>\n                      at \u22123.0\u00a0D defocus and\n                      <jats:styled-content style=\"fixed-case\">DOF<\/jats:styled-content>\n                      increased as the \u2018addition\u2019 of the\n                      <jats:styled-content style=\"fixed-case\">MFCL<\/jats:styled-content>\n                      correction increased. Finally, with the centre\u2010near\n                      <jats:styled-content style=\"fixed-case\">MFCL<\/jats:styled-content>\n                      s a linear correlation was found between\n                      <jats:styled-content style=\"fixed-case\">VA<\/jats:styled-content>\n                      at \u22123.0\u00a0D defocus and the wearer's ocular spherical aberration (\n                      <jats:italic>R<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      \u00a0=\u00a00.20\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0&lt;\u00a00.001 for 6\u00a0mm data), with the eyes exhibiting the higher positive spherical aberration experiencing worse\n                      <jats:styled-content style=\"fixed-case\">VA<\/jats:styled-content>\n                      s. By contrast, no correlation was found between\n                      <jats:styled-content style=\"fixed-case\">VA<\/jats:styled-content>\n                      and spherical aberration at 0.00\u00a0D defocus (distance vision).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>\n                      Both near\n                      <jats:styled-content style=\"fixed-case\">VA<\/jats:styled-content>\n                      and depth\u2010of\u2010focus improve with these\n                      <jats:styled-content style=\"fixed-case\">MFCL<\/jats:styled-content>\n                      s, with the effects being more pronounced for small pupils and for binocular rather than monocular vision. Coupling of the wearer's ocular spherical aberration with the aberration profiles provided by\n                      <jats:styled-content style=\"fixed-case\">MFCL<\/jats:styled-content>\n                      s affects their functionality.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/opo.12004","type":"journal-article","created":{"date-parts":[[2012,12,1]],"date-time":"2012-12-01T02:43:11Z","timestamp":1354329791000},"page":"42-50","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":57,"title":["Through\u2010focus performance with multifocal contact lenses: effect of binocularity, pupil diameter and inherent ocular aberrations"],"prefix":"10.1007","volume":"33","author":[{"given":"Sotiris","family":"Plainis","sequence":"first","affiliation":[{"name":"Institute of Vision &amp; Optics University of Crete Heraklion Crete Greece"},{"name":"Faculty of Life Sciences University of Manchester Manchester UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"George","family":"Ntzilepis","sequence":"additional","affiliation":[{"name":"Institute of Vision &amp; Optics University of Crete Heraklion Crete Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David A","family":"Atchison","sequence":"additional","affiliation":[{"name":"Institute of Health &amp; Biomedical Innovation and School of Optometry &amp; Vision Science Queensland University of Technology Brisbane Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"W Neil","family":"Charman","sequence":"additional","affiliation":[{"name":"Faculty of Life Sciences University of Manchester Manchester UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2012,12]]},"reference":[{"key":"e_1_2_7_2_1","first-page":"9","article-title":"Theoretical aspects of monovision contact lens correction","volume":"179","author":"Charman WN","year":"1980","journal-title":"Optician"},{"key":"e_1_2_7_3_1","first-page":"820","article-title":"Monovision","volume":"61","author":"Josephson JE","year":"1990","journal-title":"J Am Optom Assoc"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.2007.00488.x"},{"key":"e_1_2_7_5_1","first-page":"143","volume-title":"Presbyopia: Origins, Effects, and Treatment","author":"Nayeb\u2010Hashemi N","year":"2012"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1444-0938.2007.00242.x"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/0141-7037(90)80012-Q"},{"key":"e_1_2_7_8_1","first-page":"127","volume-title":"Presbyopia: Origins, Effects, and Treatment","author":"Kallinikos P","year":"2012"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1444-0938.2010.00524.x"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/0892-8967(93)90007-E"},{"key":"e_1_2_7_11_1","first-page":"87","article-title":"Retinal images with centred aspheric varifocal contact lenses","volume":"15","author":"Charman WN","year":"1988","journal-title":"Int Cont Lens Clinic"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e318264f3e9"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e3181fbad60"},{"key":"e_1_2_7_14_1","doi-asserted-by":"crossref","first-page":"S603","DOI":"10.3928\/1081-597X-20020901-21","article-title":"Aberration generation by contact lenses with aspheric and asymmetric surfaces","volume":"18","author":"L\u00f3pez\u2010Gil N","year":"2002","journal-title":"J Refract Surg"},{"key":"e_1_2_7_15_1","first-page":"15","article-title":"Commenting on \u201cUsing Power Profiles to Evaluate Aspheric Lenses\u201d","author":"Plainis S","year":"2011","journal-title":"Cont Lens Spectrum"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.visres.2010.04.001"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e31821c0ed8"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.opx.0000232185.00091.45"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.opx.0000216098.62165.34"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199306000-00005"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1080\/09500340701469831"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.18.001793"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1097\/ICL.0b013e3182654994"},{"key":"e_1_2_7_24_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.10-6545"},{"key":"e_1_2_7_25_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.09-5013"},{"key":"e_1_2_7_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.biopsycho.2011.01.005"},{"key":"e_1_2_7_27_1","article-title":"Using Power Profiles to Evaluate Aspheric Lenses","author":"Vogt A","year":"2011","journal-title":"Cont Lens Spectrum"},{"key":"e_1_2_7_28_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e3180dc9a60"},{"key":"e_1_2_7_29_1","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20000901-34"},{"key":"e_1_2_7_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0141-7037(86)80018-0"},{"key":"e_1_2_7_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0141-7037(95)80023-9"},{"key":"e_1_2_7_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1367-0484(97)80005-7"},{"key":"e_1_2_7_33_1","doi-asserted-by":"publisher","DOI":"10.1098\/rspb.1998.0266"},{"key":"e_1_2_7_34_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.06-0836"},{"key":"e_1_2_7_35_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-200407000-00016"},{"key":"e_1_2_7_36_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.2004.00250.x"},{"key":"e_1_2_7_37_1","doi-asserted-by":"publisher","DOI":"10.1167\/10.5.7"},{"key":"e_1_2_7_38_1","doi-asserted-by":"publisher","DOI":"10.1167\/7.6.8"}],"container-title":["Ophthalmic and Physiological Optics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fopo.12004","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/opo.12004","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T11:23:33Z","timestamp":1767785013000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/opo.12004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,12]]},"references-count":37,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2013,1]]}},"alternative-id":["10.1111\/opo.12004"],"URL":"https:\/\/doi.org\/10.1111\/opo.12004","archive":["Portico"],"relation":{},"ISSN":["0275-5408","1475-1313"],"issn-type":[{"value":"0275-5408","type":"print"},{"value":"1475-1313","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,12]]},"assertion":[{"value":"2012-08-14","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2012-10-11","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2012-12-01","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}