{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,10]],"date-time":"2026-05-10T03:48:48Z","timestamp":1778384928588,"version":"3.51.4"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2013,1,9]],"date-time":"2013-01-09T00:00:00Z","timestamp":1357689600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Ophthalmic Physiologic Optic"],"published-print":{"date-parts":[[2013,3]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To determine the association between stereoacuity and severity of glaucoma.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Stereoacuity was measured using the\n                      <jats:styled-content style=\"fixed-case\">T<\/jats:styled-content>\n                      itmus stereo test for 97 glaucoma subjects with visual acuity better than 0.3 log\n                      <jats:styled-content style=\"fixed-case\">MAR<\/jats:styled-content>\n                      (6\/12, 20\/40\n                      <jats:styled-content style=\"fixed-case\">S<\/jats:styled-content>\n                      nellen) and reliable\n                      <jats:styled-content style=\"fixed-case\">H<\/jats:styled-content>\n                      umphrey visual fields (24\u20102\n                      <jats:styled-content style=\"fixed-case\">SITA<\/jats:styled-content>\n                      standard). The severity of visual fields was graded with the\n                      <jats:styled-content style=\"fixed-case\">H<\/jats:styled-content>\n                      odapp\u2010\n                      <jats:styled-content style=\"fixed-case\">A<\/jats:styled-content>\n                      nderson\u2010\n                      <jats:styled-content style=\"fixed-case\">P<\/jats:styled-content>\n                      arrish (\n                      <jats:styled-content style=\"fixed-case\">HAP<\/jats:styled-content>\n                      ) classification and visual fields index (\n                      <jats:styled-content style=\"fixed-case\">VFI<\/jats:styled-content>\n                      ) score and the stereoacuities for different grades were compared. Presence of a significant field defect (\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0&lt;\u00a01%) in any one of the paracentral points in 10\u20132\n                      <jats:styled-content style=\"fixed-case\">SITA<\/jats:styled-content>\n                      standard\/Macular threshold was considered as a threat to fixation.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Mean\u00a0\u00b1\u00a0\n                      <jats:styled-content style=\"fixed-case\">SD<\/jats:styled-content>\n                      age of the subjects was 57.28\u00a0\u00b1\u00a014.0\u00a0years. The median [inter\u2010quartile range, (\n                      <jats:styled-content style=\"fixed-case\">IQR<\/jats:styled-content>\n                      )] stereoacuity of the 97 subjects was 50 (40\u2013100)\u00a0arc sec with 13 subjects having stereoacuity of &gt;3000\u00a0arc sec. Median (\n                      <jats:styled-content style=\"fixed-case\">IQR<\/jats:styled-content>\n                      ) stereoacuity of 97 subjects classified with\n                      <jats:styled-content style=\"fixed-case\">HAP<\/jats:styled-content>\n                      as mild, moderate and severe were 40 (40\u201340), 50 (40\u201360) and 60 (40\u2013400)\u00a0arc sec; similarly median (\n                      <jats:styled-content style=\"fixed-case\">IQR<\/jats:styled-content>\n                      ) stereoacuity of the subjects classified using\n                      <jats:styled-content style=\"fixed-case\">VFI<\/jats:styled-content>\n                      as mild, moderate and severe were 40 (40\u201355), 60 (40\u2013100) and 120 (50\u20133000)\u00a0s of arc and the difference between groups were significant (\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0&lt;\u00a00.001). Median (\n                      <jats:styled-content style=\"fixed-case\">IQR<\/jats:styled-content>\n                      ) stereoacuity in subjects with no threat to fixation (45) and threat to fixation in at least one eye (52) were 40 (40\u201360) and 70 (40\u2013800)\u00a0arc sec (\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0&lt;\u00a00.001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Decreased stereoacuity was associated with greater glaucomatous visual field loss, although it was normal with early visual field defects. Relatively moderate defects can be associated with decreased stereoacuity and it is more pronounced in the severe stages of the disease when there is a threat to fixation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/opo.12021","type":"journal-article","created":{"date-parts":[[2013,1,9]],"date-time":"2013-01-09T14:29:03Z","timestamp":1357741743000},"page":"172-178","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":21,"title":["Stereoacuity in mild, moderate and severe glaucoma"],"prefix":"10.1007","volume":"33","author":[{"given":"Yamunadevi","family":"Lakshmanan","sequence":"first","affiliation":[{"name":"Sankara Nethralaya Medical Research Foundation Chennai India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ronnie J","family":"George","sequence":"additional","affiliation":[{"name":"Sankara Nethralaya Medical Research Foundation Chennai India"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2013,1,9]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.4103\/0301-4738.53049"},{"key":"e_1_2_7_3_1","first-page":"142","article-title":"New technologies in the diagnosis and monitoring of glaucoma","volume":"2","author":"Harasymowycz PJ","year":"2004","journal-title":"Tech Ophthalmol"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(91)32119-5"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1097\/00061198-199612000-00007"},{"key":"e_1_2_7_6_1","first-page":"36","article-title":"Stereopsis in early\u2010stage primary open angle glaucoma cases","volume":"14","author":"Elgin U","year":"2005","journal-title":"Ophthalmology"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2006.091025"},{"key":"e_1_2_7_8_1","first-page":"85","article-title":"Stereopsis and contrast sensitivity binocular summation in early glaucoma","volume":"4","author":"El\u2010Gohary AA","year":"2009","journal-title":"Res J Med Med Sci"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1038\/eye.1996.51"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.08-3229"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.08-2496"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.09-4434"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.1994.tb00553.x"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1155\/2012\/271481"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1038\/sj.eye.6700036"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1097\/00061198-200304000-00009"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2007.08.037"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1097\/IJG.0b013e3181752c83"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.3109\/09286581003734878"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.2010.00811.x"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e31822f4d6a"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.survophthal.2006.12.008"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1475-1313.1996.95000348.x"},{"key":"e_1_2_7_24_1","first-page":"185","article-title":"Major review. Intermittent exotropia; basic and divergence excess type","volume":"8","author":"Cooper J","year":"1993","journal-title":"Binocul Vis Strabismus Q"},{"key":"e_1_2_7_25_1","first-page":"675","article-title":"Pupillary dilation and its effects on automated perimetry results","volume":"66","author":"Kudrna GR","year":"1995","journal-title":"J Am Optom Assoc"},{"key":"e_1_2_7_26_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1989.01070020053028"},{"key":"e_1_2_7_27_1","first-page":"125","article-title":"Interpreting automated perimetry","volume":"49","author":"Thomas R","year":"2001","journal-title":"Indian J Ophthalmol"},{"key":"e_1_2_7_28_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1444-0938.2000.tb04907.x"},{"key":"e_1_2_7_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(97)30007-4"},{"key":"e_1_2_7_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2007.09.038"},{"key":"e_1_2_7_31_1","first-page":"2212","article-title":"Predicting binocular visual field sensitivity from monocular visual field results","volume":"41","author":"Nelson\u2010Quigg JM","year":"2000","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_7_32_1","doi-asserted-by":"publisher","DOI":"10.3341\/kjo.2005.19.2.136"},{"key":"e_1_2_7_33_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2005.077719"},{"key":"e_1_2_7_34_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.06-1073"},{"key":"e_1_2_7_35_1","doi-asserted-by":"publisher","DOI":"10.1038\/sj.eye.6702305"},{"key":"e_1_2_7_36_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2004.042093"},{"key":"e_1_2_7_37_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1091-8531(03)00170-8"}],"container-title":["Ophthalmic and Physiological Optics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fopo.12021","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/opo.12021","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T11:26:47Z","timestamp":1767785207000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/opo.12021"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,1,9]]},"references-count":36,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2013,3]]}},"alternative-id":["10.1111\/opo.12021"],"URL":"https:\/\/doi.org\/10.1111\/opo.12021","archive":["Portico"],"relation":{},"ISSN":["0275-5408","1475-1313"],"issn-type":[{"value":"0275-5408","type":"print"},{"value":"1475-1313","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,1,9]]},"assertion":[{"value":"2012-06-30","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2012-12-04","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2013-01-09","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}