{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,22]],"date-time":"2026-04-22T18:42:41Z","timestamp":1776883361648,"version":"3.51.2"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2015,10,21]],"date-time":"2015-10-21T00:00:00Z","timestamp":1445385600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"name":"North Netherlands Provinces"},{"name":"European Union, European Fund for Regional Development"},{"name":"Ministry of Economic Affairs, Peaks in the Delta"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Ophthalmic Physiologic Optic"],"published-print":{"date-parts":[[2016,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>\n                      To determine if it is possible to predict the ocular wavefront aberrations of eyes with an aspheric\n                      <jats:styled-content style=\"fixed-case\">IOL<\/jats:styled-content>\n                      from the corneal shape and other readily available eye characteristics. A reliable prediction is a prerequisite for future\n                      <jats:styled-content style=\"fixed-case\">IOL<\/jats:styled-content>\n                      customisation.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Sixty pseudophakic eyes with aspheric\n                      <jats:styled-content style=\"fixed-case\">IOL<\/jats:styled-content>\n                      s of 60 patients were included. The corneal shape and the ocular wavefront aberrations were measured postoperatively with a Scheimpflug camera and an aberrometer, respectively. The elevation data of the anterior corneal surface were fitted by Zernike polynomials. Linear regression models for the Zernike coefficients describing the ocular wavefront aberrations up till the fourth order were determined, with as independent variables the Zernike coefficients describing the corneal shape, the eye (right\/left),\n                      <jats:styled-content style=\"fixed-case\">IOL<\/jats:styled-content>\n                      power, and axial length.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Linear regression equations with an explained variance (adjusted\n                      <jats:italic>R<\/jats:italic>\n                      \u2010square) above 0.50 were found for five Zernike aberration terms: defocus (\n                      <jats:italic>z<\/jats:italic>\n                      (2,0); adjusted\n                      <jats:italic>R<\/jats:italic>\n                      \u2010square 0.90), the astigmatism terms (0.81 for oblique astigmatism [\n                      <jats:italic>z<\/jats:italic>\n                      (2,\u22122)] and 0.88 for regular astigmatism [\n                      <jats:italic>z<\/jats:italic>\n                      (2,2)]), vertical coma (\n                      <jats:italic>z<\/jats:italic>\n                      (3,\u22121); 0.52), and spherical aberration (\n                      <jats:italic>z<\/jats:italic>\n                      (4,0); 0.71).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The defocus, astigmatism, vertical coma, and spherical aberration terms of the ocular wavefront are strongly associated with the corneal shape in pseudophakic eyes and may thus be predicted from the corneal shape and other eye characteristics.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/opo.12258","type":"journal-article","created":{"date-parts":[[2015,10,23]],"date-time":"2015-10-23T03:36:01Z","timestamp":1445571361000},"page":"43-50","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["From corneal shape to ocular wavefront in eyes with aspheric\n                    <scp>IOL<\/scp>\n                    s: the feasibility of\n                    <scp>IOL<\/scp>\n                    customisation"],"prefix":"10.1007","volume":"36","author":[{"given":"Tim","family":"de Jong","sequence":"first","affiliation":[{"name":"Department of Ophthalmology University of Groningen, University Medical Center Groningen Groningen the Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carmen","family":"Canovas","sequence":"additional","affiliation":[{"name":"AMO Groningen B.V. Groningen the Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Henk","family":"Weeber","sequence":"additional","affiliation":[{"name":"AMO Groningen B.V. Groningen the Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nomdo M.","family":"Jansonius","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology University of Groningen, University Medical Center Groningen Groningen the Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2015,10,21]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2006.03.061"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1038\/sj.eye.6702921"},{"key":"e_1_2_7_4_1","doi-asserted-by":"crossref","first-page":"652","DOI":"10.3928\/1081-597X-20020901-30","article-title":"Standards for reporting the optical aberrations of eyes","volume":"18","author":"Thibos LN","year":"2002","journal-title":"J Refract Surg"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.18.001793"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.17.001697"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0042-6989(01)00057-8"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.20.001841"},{"key":"e_1_2_7_9_1","doi-asserted-by":"crossref","first-page":"683","DOI":"10.3928\/1081-597X-20021101-04","article-title":"A new intraocular lens design to reduce spherical aberration of pseudophakic eyes","volume":"18","author":"Holladay JT","year":"2002","journal-title":"J Refract Surg"},{"key":"e_1_2_7_10_1","doi-asserted-by":"crossref","first-page":"12","DOI":"10.3928\/1081597X-20090101-03","article-title":"Aspheric intraocular lens selection based on corneal wavefront","volume":"25","author":"Packer M","year":"2009","journal-title":"J Refract Surg"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2009.167775"},{"key":"e_1_2_7_12_1","doi-asserted-by":"crossref","first-page":"374","DOI":"10.3928\/1081-597X-20070401-10","article-title":"Theoretical comparison of aberration\u2010correcting customised and aspheric intraocular lenses","volume":"23","author":"Piers PA","year":"2007","journal-title":"J Refract Surg"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.12.002105"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.06-0444"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.04.032"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.328.7441.702"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jspi.2010.01.008"},{"key":"e_1_2_7_18_1","doi-asserted-by":"crossref","first-page":"1320","DOI":"10.1016\/j.jcrs.2006.02.055","article-title":"Spherical aberration and contrast sensitivity after cataract surgery with the TECNIS Z9000 intraocular lens","volume":"32","author":"Mu\u00f1oz G","year":"2006","journal-title":"J Cataract Refract Surg"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2006.06.031"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.10.068"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.05.025"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2009.03.052"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.06.040"},{"key":"e_1_2_7_24_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.2009.01620.x"},{"key":"e_1_2_7_25_1","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.27.000941"},{"key":"e_1_2_7_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2005.10.032"},{"key":"e_1_2_7_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.visres.2007.10.016"},{"key":"e_1_2_7_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.09.028"},{"key":"e_1_2_7_29_1","doi-asserted-by":"crossref","first-page":"4312","DOI":"10.1167\/iovs.04-0693","article-title":"Corneal aberrations before and after small\u2010incision cataract surgery","volume":"45","author":"Guirao A","year":"2004","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_7_30_1","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1016\/j.jcrs.2006.10.021","article-title":"Change in corneal aberrations after cataract surgery with 2 types of aspherical intraocular lenses","volume":"33","author":"Marcos S","year":"2007","journal-title":"J Cataract Refract Surg"},{"key":"e_1_2_7_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.09.028"},{"key":"e_1_2_7_32_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.08-2111"},{"key":"e_1_2_7_33_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2015.04.005"},{"key":"e_1_2_7_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.10.044"},{"key":"e_1_2_7_35_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2013-303094"},{"key":"e_1_2_7_36_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.2011.00854.x"},{"key":"e_1_2_7_37_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.12-10208"},{"key":"e_1_2_7_38_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0000000000000363"},{"key":"e_1_2_7_39_1","doi-asserted-by":"publisher","DOI":"10.1111\/opo.12226"}],"container-title":["Ophthalmic and Physiological Optics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fopo.12258","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fopo.12258","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/opo.12258","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T11:24:23Z","timestamp":1767785063000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/opo.12258"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,10,21]]},"references-count":38,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2016,1]]}},"alternative-id":["10.1111\/opo.12258"],"URL":"https:\/\/doi.org\/10.1111\/opo.12258","archive":["Portico"],"relation":{},"ISSN":["0275-5408","1475-1313"],"issn-type":[{"value":"0275-5408","type":"print"},{"value":"1475-1313","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,10,21]]},"assertion":[{"value":"2015-05-29","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2015-09-08","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2015-10-21","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}