{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T03:40:14Z","timestamp":1790826014688,"version":"4.1.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2016,12,28]],"date-time":"2016-12-28T00:00:00Z","timestamp":1482883200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Ophthalmic Physiologic Optic"],"published-print":{"date-parts":[[2017,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To develop equations for accommodation stimulus and accommodation response with autorefractors when the accommodation stimulus is produced by combinations of object distances and lenses placed in front of eyes, and to give worked examples using these equations.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Simple ray tracing was used to determine stimulus and response equations, taking into account the reference positions for targets, for refraction, and for autorefractor readings.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Several examples applying equations are provided. Features of these examples include evaluating approximate calculations that have been used previously, demonstrating which equations should be used in different circumstances, how to substitute numbers into equations, how to deal with discrepancies between subjective and objective refraction, and how to deal with astigmatism. Problems associated with measuring accommodation response by placing lenses in front of the eye are discussed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Accurate equations for accommodation stimulus and accommodation response for a range of accommodation stimuli in different setups have been developed.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/opo.12340","type":"journal-article","created":{"date-parts":[[2016,12,28]],"date-time":"2016-12-28T19:05:31Z","timestamp":1482951931000},"page":"96-104","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":29,"title":["Accommodation stimulus and response determinations with autorefractors"],"prefix":"10.1007","volume":"37","author":[{"given":"David A.","family":"Atchison","sequence":"first","affiliation":[{"name":"School of Optometry &amp; Vision Sciences and Institute of Health &amp; Biomedical Innovation Faculty of Health Queensland University of Technology Kelvin Grove Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saulius R.","family":"Varnas","sequence":"additional","affiliation":[{"name":"Carl Zeiss Vision Australia Holdings Limited Zeiss Group Lonsdale Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2016,12,28]]},"reference":[{"key":"e_1_2_5_2_1","first-page":"690","article-title":"Myopic children show insufficient accommodative response to blur","volume":"34","author":"Gwiazda J","year":"1993","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_5_3_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1475-1313.1998.97000720.x"},{"key":"e_1_2_5_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.2007.00536.x"},{"key":"e_1_2_5_5_1","first-page":"454","article-title":"Free\u2010space accommodative response and minus lens\u2010induced accommodative response in preschool children","volume":"71","author":"Chen AH","year":"2000","journal-title":"Optom Clin Res"},{"key":"e_1_2_5_6_1","first-page":"2469","article-title":"AC\/A ratio, age, and refractive error in children","volume":"41","author":"Mutti DO","year":"2000","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_5_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.visres.2005.06.009"},{"key":"e_1_2_5_8_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e3181a7294f"},{"key":"e_1_2_5_9_1","doi-asserted-by":"publisher","DOI":"10.47102\/annals-acadmedsg.V35N12p868"},{"key":"e_1_2_5_10_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0000000000000094"},{"key":"e_1_2_5_11_1","first-page":"281","volume-title":"Principles of Ophthalmic Lenses","author":"Jalie M","year":"2016"},{"key":"e_1_2_5_12_1","first-page":"127","volume-title":"Bennett & Rabbetts' Clinical Visual Optics","author":"Rabbetts RB","year":"2007"},{"key":"e_1_2_5_13_1","first-page":"528","article-title":"Subject instructions and methods of target presentation in accommodation research","volume":"35","author":"Stark LR","year":"1994","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_5_14_1","doi-asserted-by":"publisher","DOI":"10.1111\/opo.12334"},{"key":"e_1_2_5_15_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.02-0264"},{"key":"e_1_2_5_16_1","doi-asserted-by":"publisher","DOI":"10.1167\/5.5.7"},{"key":"e_1_2_5_17_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199504000-00010"},{"key":"e_1_2_5_18_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.2007.00466.x"},{"key":"e_1_2_5_19_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10384-004-0175-7"},{"key":"e_1_2_5_20_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.opx.0000171337.02376.60"},{"key":"e_1_2_5_21_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.1994.tb00565.x"},{"key":"e_1_2_5_22_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e31827ce23a"},{"key":"e_1_2_5_23_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.1986.tb01135.x"},{"key":"e_1_2_5_24_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-200204000-00014"}],"container-title":["Ophthalmic and Physiological Optics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fopo.12340","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/opo.12340","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/opo.12340","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/opo.12340","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T11:24:50Z","timestamp":1767785090000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/opo.12340"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,12,28]]},"references-count":23,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2017,1]]}},"alternative-id":["10.1111\/opo.12340"],"URL":"https:\/\/doi.org\/10.1111\/opo.12340","archive":["Portico"],"relation":{},"ISSN":["0275-5408","1475-1313"],"issn-type":[{"value":"0275-5408","type":"print"},{"value":"1475-1313","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,12,28]]},"assertion":[{"value":"2016-08-24","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2016-11-07","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2016-12-28","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}