{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T10:12:35Z","timestamp":1792059155011,"version":"4.4.0"},"reference-count":46,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2022,3,19]],"date-time":"2022-03-19T00:00:00Z","timestamp":1647648000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Ophthalmic Physiologic Optic"],"published-print":{"date-parts":[[2022,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Dual\u2010focus soft contact lenses for myopia management have demonstrated to be an effective strategy to reduce myopia progression. However, this optical design has been shown to alter visual quality and accommodative function. The aim of this study was to examine the accommodative and behavioural performance during the execution of a psychomotor vigilance task (PVT) while wearing dual\u2010focus and single\u2010vision soft contact lenses.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>The steady\u2010state accommodative response was recorded with the WAM\u20105500 binocular open\u2010field autorefractor during the execution of a 10\u2010min PVT at 50\u00a0cm either with the dual\u2010focus (MiSight 1\u2010day) or single\u2010vision (Proclear 1\u2010day) soft contact lenses, using a sample of 23 healthy young adults. Each experimental session was performed on two different days in a counterbalanced order.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      A greater lag of accommodation, variability of accommodation and reaction time was found while wearing dual\u2010focus in comparison with single\u2010vision soft contact lenses (mean differences during the 10\u2010min PVT were 0.58\u00a0\u00b1\u00a00.81 D,\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0&lt;\u00a00.001; 0.31\u00a0\u00b1\u00a00.17 D,\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0&lt;\u00a00.001 and 15.22\u00a0\u00b1\u00a020.93\u00a0ms,\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0=\u00a00.002, respectively). Also, a time\u2010on\u2010task effect was found for the variability of accommodation and reaction time (\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0=\u00a00.001 and\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0&lt;\u00a00.001, respectively), observing higher values over time. However, the lag of accommodation did not change significantly as a function of time\u2010on\u2010task (\n                      <jats:italic>p<\/jats:italic>\n                      \u00a0=\u00a00.33).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Dual\u2010focus soft contact lens wear influences the steady\u2010state accommodative response and behavioural performance during the execution of a visual vigilance task in the short\u2010term. Eye care practitioners should be aware of these effects when prescribing these lenses for myopia management, and provide specific recommendations according to the individual visual needs.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/opo.12978","type":"journal-article","created":{"date-parts":[[2022,3,19]],"date-time":"2022-03-19T11:53:42Z","timestamp":1647690822000},"page":"753-761","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Changes in accommodation and behavioural performance with a contact lens for myopia management: A comparison between a dual\u2010focus and a single\u2010vision soft contact lens"],"prefix":"10.1007","volume":"42","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4571-873X","authenticated-orcid":false,"given":"Beatriz","family":"Redondo","sequence":"first","affiliation":[{"name":"CLARO (Clinical and Laboratory Applications of Research in Optometry) Research Group, Department of Optics, Faculty of Sciences University of Granada  Granada Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8091-2373","authenticated-orcid":false,"given":"Jes\u00fas","family":"Vera","sequence":"additional","affiliation":[{"name":"CLARO (Clinical and Laboratory Applications of Research in Optometry) Research Group, Department of Optics, Faculty of Sciences University of Granada  Granada Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rub\u00e9n","family":"Molina","sequence":"additional","affiliation":[{"name":"CLARO (Clinical and Laboratory Applications of Research in Optometry) Research Group, Department of Optics, Faculty of Sciences University of Granada  Granada Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tom\u00e1s","family":"Gal\u00e1n","sequence":"additional","affiliation":[{"name":"CLARO (Clinical and Laboratory Applications of Research in Optometry) Research Group, Department of Optics, Faculty of Sciences University of Granada  Granada Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pedro","family":"Machado","sequence":"additional","affiliation":[{"name":"CLARO (Clinical and Laboratory Applications of Research in Optometry) Research Group, Department of Optics, Faculty of Sciences University of Granada  Granada Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8036-2532","authenticated-orcid":false,"given":"Raimundo","family":"Jim\u00e9nez","sequence":"additional","affiliation":[{"name":"CLARO (Clinical and Laboratory Applications of Research in Optometry) Research Group, Department of Optics, Faculty of Sciences University of Granada  Granada Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,3,19]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.preteyeres.2015.12.001"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(12)60272-4"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2016.01.006"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0000000000001367"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.preteyeres.2020.100923"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2010.10.035"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1111\/opo.12686"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2015.11.010"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1002\/14651858.CD004916.pub3"},{"key":"e_1_2_9_11_1","volume-title":"The impact of myopia and high myopia","author":"World Health Organization","year":"2016"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0000000000000036"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0000000000001410"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0000000000000773"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.11-7260"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1111\/opo.12332"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.1111\/opo.12729"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e3182812205"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clae.2019.12.002"},{"key":"e_1_2_9_20_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0000000000001665"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0000000000001044"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1097\/ICL.0000000000000100"},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clae.2015.09.004"},{"key":"e_1_2_9_24_1","doi-asserted-by":"publisher","DOI":"10.1111\/aos.13173"},{"key":"e_1_2_9_25_1","doi-asserted-by":"publisher","DOI":"10.1097\/ICL.0000000000000460"},{"key":"e_1_2_9_26_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40662\u2010020\u201000204\u20104"},{"key":"e_1_2_9_27_1","doi-asserted-by":"publisher","DOI":"10.1155\/2020\/8067657"},{"key":"e_1_2_9_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.visres.2007.03.007"},{"key":"e_1_2_9_29_1","first-page":"67","article-title":"Effect of retinal defocus on rapid serial visual presentation (RSVP) digit recognition","volume":"20","author":"Xu JJ","year":"2009","journal-title":"J Behav Optom"},{"key":"e_1_2_9_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.visres.2012.04.017"},{"key":"e_1_2_9_31_1","doi-asserted-by":"publisher","DOI":"10.3758\/BF03193146"},{"key":"e_1_2_9_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.visres.2004.01.001"},{"key":"e_1_2_9_33_1","doi-asserted-by":"publisher","DOI":"10.1080\/135062899394885"},{"key":"e_1_2_9_34_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1469\u20108986.1973.tb00801.x"},{"key":"e_1_2_9_35_1","doi-asserted-by":"publisher","DOI":"10.1111\/opo.12438"},{"key":"e_1_2_9_36_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-197304000-00002"},{"key":"e_1_2_9_37_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.2009.00687.x"},{"key":"e_1_2_9_38_1","doi-asserted-by":"publisher","DOI":"10.1093\/sleep\/34.5.581"},{"key":"e_1_2_9_39_1","volume-title":"Clinical management of binocular vision. Heterophoric, accommodative, and eye movement disorders","author":"Scheiman M","year":"2013"},{"key":"e_1_2_9_40_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0000000000001214"},{"key":"e_1_2_9_41_1","doi-asserted-by":"publisher","DOI":"10.1167\/8.3.33"},{"key":"e_1_2_9_42_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2017.07.031"},{"key":"e_1_2_9_43_1","doi-asserted-by":"publisher","DOI":"10.1111\/opo.12614"},{"key":"e_1_2_9_44_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clae.2020.03.003"},{"key":"e_1_2_9_45_1","first-page":"4725","article-title":"Accommodative micro\u2010fluctuations wearing multifocal soft contact lenses","volume":"53","author":"Shibata Y","year":"2012","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_9_46_1","doi-asserted-by":"publisher","DOI":"10.1080\/02713683.2019.1645182"},{"key":"e_1_2_9_47_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clae.2015.07.005"}],"container-title":["Ophthalmic and Physiological Optics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/opo.12978","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/opo.12978","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/opo.12978","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T11:26:44Z","timestamp":1767785204000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/opo.12978"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3,19]]},"references-count":46,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2022,7]]}},"alternative-id":["10.1111\/opo.12978"],"URL":"https:\/\/doi.org\/10.1111\/opo.12978","archive":["Portico"],"relation":{},"ISSN":["0275-5408","1475-1313"],"issn-type":[{"value":"0275-5408","type":"print"},{"value":"1475-1313","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,3,19]]},"assertion":[{"value":"2021-11-02","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-02-18","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-03-19","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}