{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,8]],"date-time":"2026-04-08T21:20:08Z","timestamp":1775683208818,"version":"3.50.1"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2024,3,3]],"date-time":"2024-03-03T00:00:00Z","timestamp":1709424000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100007817","name":"Alcon Research Institute","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007817","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Ophthalmic Physiologic Optic"],"published-print":{"date-parts":[[2024,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To determine the number of previous contact lens (CL) wearers who could be comfortably refitted into delefilcon A (DAILIES TOTAL1\u00ae) CLs.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This was a 6\u2010month, three\u2010visit study that recruited subjects who discontinued CLs within the past 2\u2009years because of discomfort or dryness symptoms. Subjects were required to have Standard Patient Evaluation of Eye Dryness (SPEED) questionnaire scores \u22643 and to be able to wear spherical study CLs. Subjects were asked to complete a \u00b150 comfort visual analogue scale (VAS) at 1\u2009month and a Likert questionnaire after 1 and 6\u2009months of CL wear to understand the subjects' CL experience.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>All 60 subjects who were fitted with the study CLs were still wearing them after 1\u2009month, while one subject had dropped out by 6\u2009months. Subjects had a median (interquartile range) age of 24.0 (7.0) years (71.7% female). They reported a median VAS score of 44.0 (8.0) units at the 1\u2010month visit, with all reporting a comfortable score. At the 1\u2010month\/6\u2010month visits, 98.3%\/93.2%, 86.5%\/78.0% and 93.2%\/91.5% of subjects responded that they were very satisfied or satisfied with their vision, their end\u2010of\u2010day CL comfort and overall CL comfort, respectively. The same subjects responded that they were very likely or likely to continue to wear the study CLs at 1 (89.6%) and 6\u2009months (80.7%) and to recommend the study CLs to a friend at 1 (98.3%) and 6\u2009months (93.2%).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The results suggest that when encountering a CL dropout, a practitioner could educate a patient about trying an alternative CL and consider delefilcon A lenses as an option.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/opo.13299","type":"journal-article","created":{"date-parts":[[2024,3,4]],"date-time":"2024-03-04T01:48:51Z","timestamp":1709516931000},"page":"686-692","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Refitting contact lens dropouts into a modern daily disposable contact lens"],"prefix":"10.1007","volume":"44","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4208-6175","authenticated-orcid":false,"given":"Chris","family":"Lievens","sequence":"first","affiliation":[{"name":"Southern College of Optometry  Memphis Tennessee USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrew D.","family":"Pucker","sequence":"additional","affiliation":[{"name":"School of Optometry University of Alabama at Birmingham  Birmingham Alabama USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elyse","family":"Rayborn","sequence":"additional","affiliation":[{"name":"Southern College of Optometry  Memphis Tennessee USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shane","family":"Kannarr","sequence":"additional","affiliation":[{"name":"Kannarr Eye Care  Pittsburg Kansas USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katherine","family":"Bickle","sequence":"additional","affiliation":[{"name":"ProCare Vision Center  Granville Ohio USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Catherine","family":"Hogan","sequence":"additional","affiliation":[{"name":"Southern College of Optometry  Memphis Tennessee USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Quentin X.","family":"Franklin","sequence":"additional","affiliation":[{"name":"School of Optometry University of Alabama at Birmingham  Birmingham Alabama USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Christensen","sequence":"additional","affiliation":[{"name":"Southern College of Optometry  Memphis Tennessee USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,3,3]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.2147\/OPTO.S198637"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.1097\/ICL.0b013e318271caf4"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0000000000001290"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199303000-00011"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1475-1313.2002.00066.x"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e3181971985"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/J.CLAE.2022.101579"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1097\/ICL.0b013e3182480e97"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2002.07.001"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/J.CLAE.2021.101516"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clae.2017.12.019"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtos.2014.06.002"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000000712"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0b013e318242fd60"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.18-24016"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.2147\/OPTO.S403319"},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.1111\/opo.12828"},{"key":"e_1_2_10_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbi.2008.08.010"},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbi.2019.103208"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.5812\/ijem.3505"},{"key":"e_1_2_10_22_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.13-13215"},{"key":"e_1_2_10_23_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2125.1978.tb01676.x"},{"key":"e_1_2_10_24_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0000000000000965"}],"container-title":["Ophthalmic and Physiological Optics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/opo.13299","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T11:24:16Z","timestamp":1767785056000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/opo.13299"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3,3]]},"references-count":23,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2024,6]]}},"alternative-id":["10.1111\/opo.13299"],"URL":"https:\/\/doi.org\/10.1111\/opo.13299","archive":["Portico"],"relation":{},"ISSN":["0275-5408","1475-1313"],"issn-type":[{"value":"0275-5408","type":"print"},{"value":"1475-1313","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,3,3]]},"assertion":[{"value":"2023-11-28","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-02-21","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-03-03","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}